background image

8

102989

WARNING ICON

G 001

 WARNING

Never install the heater

• in a bedroom or bathroom except as a vented appliance (see

page 13)

• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects

are less than 36 inches from the front, top, or sides of the heater

• in high traffic areas
• in windy or drafty areas

INSTALLING

NOTICE

A qualified service person must install heater. Follow all local codes.

 WARNING

Before installing in a solid fuel burning fireplace, the chimney flue
and firebox must be cleaned of soot, creosote, ashes and loose paint
by a qualified chimney cleaner. Creosote will ignite if highly heated.
Inspect chimney flue for damage. If damaged, operate heater with
flue damper closed.

WARNING ICON

G 001

 WARNING

Seal any fresh air vents or ash clean-out doors located on floor or wall
of fireplace. If not, drafting may cause pilot outage or sooting. Use a
heat-resistant sealant. Do not seal chimney flue damper.

WARNING ICON

G 001

 CAUTION

This heater creates warm air currents. These currents move heat
to wall surfaces next to heater. Installing heater next to vinyl or
cloth wall coverings or operating heater where impurities in the air
(such as tobacco smoke) exist, may discolor walls.

IMPORTANT:

 Vent-free heaters add moisture to the air. Although this is beneficial,

installing heater in rooms without enough ventilation air may cause mildew to form
from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7.

CHECK GAS TYPE

Use only propane gas. If your gas supply is not propane, do not install heater. Call
dealer where you bought heater for proper type heater.

NOTICE

State or local codes may only allow operation of this appliance in a
vented configuration. Check your state or local codes.

Содержание Comfort Glow CGS2718P

Страница 1: ...not use any phone in your build ing Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call the fire department In...

Страница 2: ...Propane Gas Propane gas is odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exis...

Страница 3: ...reen is closed before running heater 10 This log heater is designed to be smokeless If logs ever appear to smoke turn off heater and call a qualified service person Note During initial operation sligh...

Страница 4: ...perate heater as a vented product by opening flue damper Safety Pilot This heater has a pilot with an Oxygen Depletion Sensor Shutoff System ODS The ODS pilot is a required feature for vent free room...

Страница 5: ...ances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space...

Страница 6: ...heater ___________________ Btu Hr Gas fireplace logs ___________________ Btu Hr Other gas appliances ___________________ Btu Hr Total ___________________ Btu Hr Example Gas water heater 40 000 Btu Hr...

Страница 7: ...red size of ventilation grills or ducts WARNING ICON G 001 WARNING Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appl...

Страница 8: ...rashclean outdoorslocatedonfloororwall of fireplace If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING ICON G 001 CAUTION This heate...

Страница 9: ...ed for use with these log heaters Minimum Wall and Ceiling Clearances see Figure 4 A Clearances from the side of the fireplace opening to any combustible wall should not be less than 16 inches B Clear...

Страница 10: ...rial behind it Non combustible material must extend at least 8 up for all models If non combus tible material is less than 12 you must install the fireplace hood accessory 24 model only See chart belo...

Страница 11: ...tion page 13 Figure 6 Minimum Mantel Clearances Without Using Hood If above minimum clearances are not met you must have a hood Follow minimum clearances shown in Figure 7 when using hood Non Combusti...

Страница 12: ...9 Minimum Fireplace Clearances Above Combustible Flooring If your installation does not meet the above minimum clearances you must operate the logs only with the flue damper open OR raise the mantel t...

Страница 13: ...on Ifreasonsnumber1or2aboveapplytoyou youmustpermanentlyopenchimneyflue damper Youmustinstallthedamperclampaccessory toorder seeAccessories page 29 This will insure vented operation see Figure 10 The...

Страница 14: ...t sealant lightly to male threads of the fitting to be threaded into gas regulator Connect approved flexible gas hose to gas regulator of heater see Figure 11 IMPORTANT Hold gas regulator with wrench...

Страница 15: ...ded Before installing heater make sure you have the items listed below external regulator supplied by installer see page 16 piping check local codes sealant resistant to propane LP gas manual shutoff...

Страница 16: ...14 page 17 Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves WARNING ICON G 001 CAUTIO...

Страница 17: ...end of gas pipe where manual shutoff valve was connected WARNING ICON G 001 WARNING Never use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming...

Страница 18: ...l shutoff valve see Figure 16 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 4 Correct all leaks at once Pressure Testing Heater Gas Connections 1 Open manual shutoff...

Страница 19: ...e pegs into the holes in the grate base behind the burner see Figure 17 2 Locate the notches on the back of the front log 2 Slide these notches over the tabs of the grate base see Figure 18 3 Locate t...

Страница 20: ...he gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in a fi...

Страница 21: ...hts Note If pilot does not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure...

Страница 22: ...Pilot Flame Pattern Figure 23 Incorrect Pilot Flame Pattern If pilot flame pattern is incorrect as shown in Figure 23 turn heater off see To Turn Off Gas to Appliance page 21 see Troubleshooting pages...

Страница 23: ...object to clean ODS pilot This can damage ODS pilot unit POSSIBLE CAUSE 1 Ignitor electrode not con nected to ignitor cable 2 Ignitor cable pinched or wet 3 Piezo ignitor nut is loose 4 Broken ignitor...

Страница 24: ...Replace thermocouple 7 Replace control valve OBSERVED PROBLEM When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob is relea...

Страница 25: ...Replace gas regulator 3 Problem will stop after a few hours of operation 1 Refer to Air for Com bustion and Ventilation requirements page 5 1 Turn control knob to LO position and let warm up for a mi...

Страница 26: ...clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during comb...

Страница 27: ...ressure 8 0 W C 8 0 W C Inlet Gas Pressure in of water Maximum 14 14 Minimum 11 11 Shipping Weight 27 lbs 29 lbs For the purpose of input adjustment When gas pressure is too low pilot will not stay li...

Страница 28: ...acement parts and accessories Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 All...

Страница 29: ...bove fireplace LAVA ROCK GA6060 For all models Order when additional rock is desired 3 lb bag DAMPER CLAMP GA6080 For variably controlled models Permanently opens chimney flue damper for vented operat...

Страница 30: ...30 102989 ILLUSTRATED PARTS BREAKDOWN 4 2 1 3 12 21 10 11 21 7 21 5 6 8 9 15 14 16 19 22 18 13 19 17 20 2 20 1 20 18 23 CGS2718P CGS3124P...

Страница 31: ...2963 01 102773 01 Burner 1 13 102568 08 102568 08 Control Valve 1 14 098508 01 098508 01 Valve Retainer Nut 1 15 098354 01 098354 01 Control Knob 1 16 102445 01 102445 01 Piezo Ignitor 1 17 098249 01...

Страница 32: ...instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse...