background image

7

103575

Figure 2 - Ventilation Air from Inside Building

Or 

Remove 

Door into 

Adjoining 

Room, 

Option 3

Ventilation Grills 

Into Adjoining Room,

Option 2

12"

12"

Ventilation

Grills

into Adjoining

Room, 

Option 1

Continued

AIR FOR

COMBUSTION

AND

VENTILATION

Continued

 WARNING

If the area in which the heater may be operated is smaller than
that defined as an unconfined space, provide adequate combus-
tion and ventilation air by one of the methods described in the
National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3. or appli-
cable local codes.

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to
an adjoining unconfined space, you must provide two permanent openings: one within
12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces
(see options 1 and 2, Figure 2). You can also remove door into adjoining room (see
option 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1,
Section 5.3, Air for Combustion and Ventilation
 for required size of ventilation grills
or ducts.

 WARNING

Rework worksheet, adding the space of the adjoining unconfined
space. The combined spaces must have enough fresh air to supply all
appliances in both spaces.

Содержание Comfort Glow CGP10T

Страница 1: ...iquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately...

Страница 2: ...e or anemia those under the influence of alcohol and those at high altitudes Propane LP Gas Propane LP gas is odorless An odor making agent is added to propane LPgas Theodorhelpsyoudetectapropanegasle...

Страница 3: ...shutsdownthe heaterifnotenoughfreshairisavailable SeeAirforCombustionandVentilation pages 5 through 8 7 Keepallairopeningsinthefrontandbottomofheaterclearandfreeofdebris This will insure enough air fo...

Страница 4: ...omfort This can also result in lower gas bills LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of The National Fuel Gas Code AN...

Страница 5: ...kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors a...

Страница 6: ...heater ___________________ Btu Hr Gas fireplace logs ___________________ Btu Hr Other gas appliances ___________________ Btu Hr Total ___________________ Btu Hr Example Gas water heater 40 000 Btu Hr...

Страница 7: ...cal codes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must provide two perma...

Страница 8: ...nt openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow...

Страница 9: ...NING Maintain the minimum clearances shown in Figure 4 page 10 If you can provide greater clearances from floor ceiling and joining wall Continued WARNING Never install the heater in a bathroom in a r...

Страница 10: ...m clearances shown in Figure 5 If you can provide greater clearances from floor and joining wall For convenience and efficiency install heater where there is easy access for operation inspection and s...

Страница 11: ...Drill holes at marked locations using 5 16 drill bit For solid walls concrete or masonry drill at least 1 1 4 deep 2 Fold wall anchor see Figure 6 Figure 8 Tightening Anchors Thin Walls 1 4 to 1 2 thi...

Страница 12: ...eater is firmly secured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connections and checking for leaks see pages 13 15 INSTALLINGTO WA...

Страница 13: ...upply line as shown in Figure 13 page 14 Locate sediment trap where it is within reach for cleaning Locate sediment trap where trapped matter is not likely to freeze A sediment trap traps moisture and...

Страница 14: ...ator 2 Cap off open end of gas pipe where manual shutoff valve was connected Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Connection Heater Cabinet Pressure Regulator Tee Joint Pip...

Страница 15: ...rming show a leak 4 Correct all leaks at once PRESSURE TESTING HEATER GAS CONNECTIONS 1 Open manual shutoff valve see Figure 14 2 Open propane LP supply tank valve 3 Make sure control knob of heater i...

Страница 16: ...supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified serv...

Страница 17: ...panel If needed keep pressing ignitor button until pilot lights Note If pilot does not stay lit refer to Troubleshooting pages 21 through 24 Also contact a qualified service person or gas supplier fo...

Страница 18: ...the room may exceed the set temperature If so the burner will shut off The burner will cycle back on when room temperature drops below the set temperature The control knob can be set to any heat leve...

Страница 19: ...ermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down GRH OV 007 GOOD PILOT LP Thermocouple Pilot Burner Figure 18 Correct Pilot Flame Pattern If pi...

Страница 20: ...of orange flame INSPECTING BURNER Continued WARNING If yellow tipping occurs your heater could produce increased levels of carbon monoxide If burner flame pattern shows yellow tipping follow instruct...

Страница 21: ...troubleshooting items are listed in order of operation WARNING Turn off heater and let cool before servicing Only a qualified service person should service and repair heater CAUTION Never use a wire n...

Страница 22: ...n until snug then tighten 1 4 turn more 6 A Contact local propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 21 or replace ODS pilot assembly 7 Replace thermocouple 8 Replace c...

Страница 23: ...line Have gas checked by local propane LP gas company 3 Observe minimum installation clearances see Figure 4 page 10 4 Clean burner see Cleaning and Mainte nance page 21 or replace burner orifice POSS...

Страница 24: ...tact qualified service person 1 Ventilate room Stop using odor causing products while heater is running 2 Refill supply tank 3 Locate and correct all leaks see Checking Gas Connections page 14 1 Open...

Страница 25: ...aximum 14 Minimum 11 Dimensions Inches H x W x D Heater Including knobs and grill 21 1 2 x 13 1 2 x 7 Carton 25 1 4 x 16 3 4 x 7 1 2 Weight pounds Shipping 19 When gas pressure is too low pilot will n...

Страница 26: ...26 103575 ILLUSTRATED PARTS BREAKDOWN 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 16 17 18 23 24 27 14 22 20 26 25 19 25 21 12 2 12 1 ODS PILOT CGP10T CGP10TL...

Страница 27: ...r Unit 1 10 098271 03 Ignitor Cable 1 11 098249 01 Nut M5 2 12 099059 03 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor Electrode 1 13 099386 02 Burner 1 14 099387 11 Pilot...

Страница 28: ...of this product If they cannot supply original replace ment part s either contact your nearest Parts Central see page 29 or call DESA International s Parts Department at 1 800 972 7879 for referral in...

Страница 29: ...Parts Department Dayton Hardware P O Box 275 North Dayton Station Dayton OH 45404 All States 513 258 3721 OH 1 800 762 3426 Parts Department Halco Enterprises 208 Carter Drive Unit 21 West Chester PA...

Страница 30: ...________ _________________________________________________________________ _________________________________________________________________ ___________________________________________________________...

Страница 31: ...________ _________________________________________________________________ _________________________________________________________________ ___________________________________________________________...

Страница 32: ...swarranty Theheater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in origina...

Отзывы: