manualshive.com logo in svg
background image

Содержание Comfort Glow CGN10R

Страница 1: ...neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agen...

Страница 2: ...lt 6 This heater needs fresh outside air ventilation to run properly This heater has an oxygen depletion sensor ODS pilot light safety system The ODS shuts down the heater if not enough fresh air is a...

Страница 3: ...ur space and provide adequate ventilation Unusually Tight Construction The air that leaks around doors and win dows may provide enough fresh air for combustion and ventilation However in buildings of...

Страница 4: ...Hr Vented gas heater Btu Hr Gas fireplace logs Bta Hr Other gas appliances Btu Hr Total Btu Hr Example Gas water heater 40 000 Btu Hr Vent free heater 10 000 Btu Hr Total 50 000 Btu Hr Do not include...

Страница 5: ...on for required size of ventilation grills or ducts WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh sir to supply all appliances...

Страница 6: ...oom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 36 inches from the front top or sides of the heater as a fireplace insert in high traffic areas...

Страница 7: ...sonry drill at least 1 1 4 deep 2 Fold wall anchor see Figure 6 3 Insert wall anchor wings first into hole Tap anchor flush to wall Figure 6 Folding Anchor 4 For thin walls liT or less insert red key...

Страница 8: ...nt sealant that is resistant to liquid petroleum LP gas Install sediment trap in supply line as shown in Figure 12 Locate sediment trap where it is within reach for cleaning Locate sedi ment trap wher...

Страница 9: ...ressures Equal To or Less Than 1 2 PSIG 1 2 Close manual shutoff valve see Figure 13 Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas met...

Страница 10: ...ive 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information If you don t smell gas go to the next step 5 Press in control kn...

Страница 11: ...NOFFN Figure 17 Burner Patterns Pilot Burner mhe_ _ _ TO TURN OFF GAS 1 TO APPLIANCE Shutting Off Heater 1 l am controlknob clockwise to the OFF position Shutting Off Burner Only pilot stays lit 1 Tu...

Страница 12: ...d to the PILOT position there is no spark at ODS pilot I 2 3 4 5 Ignitor electrode positioned wrong 1 Replace ignitor Ignitor electrode broken Ignitor electrode not connected to ignitor cable Ignitor...

Страница 13: ...3 Inlet gas pressure is too low 1 Clean burner orifice s see Cleaning and Maintenance page 15 or replace burner orifice s 2 Replace burner orifice s 3 Contact local natural gas company Delayed ignitio...

Страница 14: ...ir for Combustion and Ventilation requirements page 3 2 Contact local natural gas company 3 Clean ODS pilot see Cleaning and Maintenance page 15 GasodorevenwhencontrolknobisinOFF 1 Gasleak SeeWarnlngs...

Страница 15: ...DESA International s Parts Department at 1 800 972 7879 for referral information When calling DESA International have ready model number of your heater the replacement part number SERVICE PUBLICATIONS...

Страница 16: ...GAS RESIDENTIAL HEATERS ILLUSTRATED PARTS BREAKDOWN CGN10R CGNIORL _J HEATER EXPLODED VIEW _J _J _J _J J ODS PILOT 24 11 16 103549...

Страница 17: ...01 24 102445 01 25 098271 03 Screw 10 x 318 Front Panel Assembly Earth Tone CGN10R Front Panel Assembly Ivory CGN10RL Grill Guard Grill Guard Clip Reflector Assembly Screw Hex 8 x 1 4 ODS Pilot Assemb...

Страница 18: ...GAS RESIDENTIAL HEATERS NOTES 18 _...

Страница 19: ...OWNER S MANUAL 19...

Страница 20: ...warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack ofpropor maintenance or d...

Отзывы: