background image

14

105616

VENT-FREE PROPANE COMPACT FIREPLACE

OPTIONAL WIRELESS
HAND-HELD REMOTE
CONTROL ACCESSORIES
(CGHRC Series and
CGHRCT Series)

Installing Receiver

1.

Remove screws.

2.

Disconnect switch wires from the con-
trol valve.

3.

Remove switch plate (see Figure 22).
Discard switch plate after removing.
Save the screws.

4.

Locate the battery clip mounted on the
back of the receiver (see Figure 23).

5.

Slide 9-volt battery (not included)
through the clip.

6.

Attach the terminal wires to the battery
(see Figure 23).

7.

Connect wires as shown in Figure 24.

8.

Install remote receiver unit onto gas
heater base using the two screws re-
moved in step one (see Figure 24).

Figure 22 - Switch Plate and Wiring
Harness

Screw

Switch Plate

Black Wire

Red Wire

Figure 23 -  Attaching Battery to Receiver

Battery Clip

9-Volt Battery

Receiver

Terminal
Wires

INSTALLATION

Continued

Figure 24 - Installing Remote Receiver

* Wire harness provided in the fireplace
hardware pack.

Installing 9-Volt Battery in Hand-
Held Remote Control Unit

1.

Remove battery cover on back of re-
mote control unit.

 2. Attach terminal wires to the battery (not

included). Place battery into the battery
housing.

3.

Replace battery cover onto remote con-
trol unit.

Figure 25 - Installing Battery in Hand-
Held Remote Control Unit

Remote
Receiver

Wires from
Valve

Wire Harness*

Black Wire

Red Wire

Red Wire

Black Wire

Battery
Cover

9-Volt
Battery

Terminal
Wires

Remote
Control Unit

Battery
Housing

Heater Base

Содержание Comfort Glow CGCF26PRA

Страница 1: ...s or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from...

Страница 2: ...he control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 9 This fireplace is designed to be sm...

Страница 3: ...es one hardware packet and one remote con trol packet which includes batteries 4 Checkfireplaceforanyshippingdamage If fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FE...

Страница 4: ...ort see Figure 2 The log should fit flat against top of burner support Place two 10 one inch long screws through burner support into the log and tighten Place branches on branch support see Figure 2 6...

Страница 5: ...ila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven tilation air Read the f...

Страница 6: ...nt gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ___________ Btu...

Страница 7: ...re 4 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an a...

Страница 8: ...from the front top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas IMPORTANT Vent freefireplacesaddmois ture to the air Although this is beneficial insta...

Страница 9: ...ect blower to electrical source Option one Route blower electrical cord through side or rear access door of fireplace Plug electrical cord into electrical outlet 1 Frame in rough opening Use dimen sio...

Страница 10: ...x assembly Blower accessory should be installed if it is being used see Accesso ries page 24 1 Unscrew four brass screws that attach top louver to fireplace Remove louver from fireplace and set aside...

Страница 11: ...male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged fireplace valves Installsedimenttrapinsupplylineasshown in Figure 17 Locate sediment t...

Страница 12: ...o allow accessibility fromthefireplace seeFigure19 The flexible gas supply line con nection to the manual shutoff valve should be accessible Branch Support Screen Screen Shipping Screw Shoulder Screw...

Страница 13: ...supply tank to manual shutoff valve see Fig ure 21 Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 4 Correct all leaks at once INSTALLATION Continued CHECKING GAS CON...

Страница 14: ...ed in step one see Figure 24 Figure 22 Switch Plate and Wiring Harness Screw Switch Plate Black Wire Red Wire Figure 23 Attaching Battery to Receiver Battery Clip 9 Volt Battery Receiver Terminal Wire...

Страница 15: ...light pilot The pilot is attached to the burner If needed keep pressing ig nitor button until pilot lights Note If pilot does not stay lit con tact a qualified service person or gas supplier for repa...

Страница 16: ...lector switch in the REMOTE posi tion when the pilot is not lit This will drain the battery IMPORTANT Be sure to press the ON OFF buttons on the hand held remote control unit for up to 3 sec onds to...

Страница 17: ...Troubleshooting pages 19 through 21 Pilot Burner Thermocouple INSPECTING BURNERS CLEANING AND MAINTENANCE WARNING Turn off fireplace and let cool before cleaning CAUTION You must keep control areas bu...

Страница 18: ...r fireplace the replacement part number SPECIFICATIONS Btu Variable 15 000 26 000 Type Gas Propane LP Only Ignition Piezo Manifold Pressure 8 W C Inlet Gas Pressure in of water Maximum 14 Minimum 11 D...

Страница 19: ...ect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace...

Страница 20: ...ion and Venti lation requirements page 5 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane gas com...

Страница 21: ...burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This is common with...

Страница 22: ...ANE COMPACT FIREPLACE ILLUSTRATED PARTS BREAKDOWN CGCF26PRA 11 11 29 30 38 38 7 35 26 36 10 40 40 7 24 1 2 8 15 6 21 31 32 13 18 22 5 27 20 19 16 28 1 28 2 23 39 25 33 34 19 14 14 1 37 18 12 4 4 39 9...

Страница 23: ...l Base 1 16 102649 02CJ Branch Support 1 17 097159 04 Piezo 1 18 099387 13 Pilot Tube 1 19 098271 07 Ignitor Cable 1 20 098251 03 Injector 1 21 098250 01 Injector Holder 1 22 098249 01 Nut M5 6 23 103...

Страница 24: ...classic lines Available in a walnut finish or an unfinished hardwood ready to stain or paint Complete assembly instructions in cluded Three sided brass trim kit included ACCESSORIES Purchase these fi...

Страница 25: ...342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Parts Department FBD 1349 Adams St Bowling Green KY 42103 3413 502 846 1199 1 800 654 8534 Fax 1 800 846 0090...

Страница 26: ...defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner...

Отзывы: