background image

www.desatech.com

113897-01A

34

REPLACEMENT PARTS

Note: 

Use only original replacement parts. This 

will  protect  your  warranty  coverage  for  parts 

replaced under warranty. 

PARTS UNDER WARRANTY

Contact  authorized  dealers  of  this  product.  If 

they canʼt supply original replacement part(s), 

call DESA Heating Productsʼ Technical Service 

Department at 1-866-672-6040.
When  calling  DESA  Heating  Products,  have 

ready
•  your name
•  your address
•  model and serial numbers of your heater 
•  how heater was malfunctioning
•  type of gas used (propane/LP or natural gas)
•  purchase date
Usually, we will ask you to return the part to the 

factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they 

canʼt  supply  original  replacement  part(s),  call 

DESA Heating Products at 1-866-672-6040 for 

referral information.
When  calling  DESA  Heating  Products,  have 

ready
•  model number of your heater 
•  the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

•  pilot will not stay lit
•  burners will have delayed ignition
•  heater will not produce specified heat
•  for propane/LP units, propane/LP gas supply 

may be low

You may feel your gas pressure is too low. If so, con-

tact your local propane/LP or natural gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, 

operation, or troubleshooting. If so, contact DESA 

Heating Productsʼ Technical Service Department 

at 1-866-672-6040. When calling please have your 

model and serial numbers of your heater ready.
You can also visit DESA Heating Productsʼ techni-

cal services web site at 

www.desatech.com.

PARTS CENTRAL

These Parts Centrals are privately owned businesses. 

They have agreed to support our customerʼs needs by 

providing original replacement parts and accessories.

Tool and Equipment, Co.

1348 Dixwell Avenue

Hamden, CT 06514-0322

1-800-397-7553

203-248-7553

Parts Department

Portable Heater Parts

342 N. County Rd. 400 East

Valparaiso, IN 46383-9704

All States 

219-462-7441

1-888-619-7060

[email protected]

[email protected]

FBD

1349 Adams Street

Bowling Green, KY 42103-3414

270-846-1199

1-800-654-8534

Fax: 1-800-846-0090

[email protected]

Master Parts Dist.

1251 Mound Ave NW

Grand Rapids, MI 49504-2672

616-791-0505

1-800-446-1446

Fax: 616-791-8270

www.nbmc.com

Washer Equipment Co.

1715 Main Street

Kansas City, MO 64108-2195

KS, MO, AR

816-842-3911

www.washerparts.com

East Coast Energy Products 

707 Broadway

W. Long Branch, NJ 07764-1542

732-870-8809

1-800-755-8809

www.njplaza.com/ecep

Laporte’s Parts & Service

2444 N. 5th Street

Hartsville, SC 29550-7704

843-332-0191

Parts Department

Cans Unlimited, Inc. 

P.O. Box 645

Taylor, SC 29687-0013

All States 

803-879-3009

1-800-845-5301

[email protected]

Содержание Comfort Glow CF26NRA

Страница 1: ...light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot re...

Страница 2: ...in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indi cated on the rating plate This appliance i...

Страница 3: ...ll warn ings Keep this manual for reference It is your guide to safe and proper operation of this heater WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower...

Страница 4: ...eds fresh air ventilation to run properly This replace has an Oxygen Deple tion Sensing ODS safety shutoff system The ODS shuts down the replace if not enough fresh air is available See Air for Combus...

Страница 5: ...air for this and other fuel burning appliances in your home Today s homes are built more energy ef cient than ever New materials increased insulation and new construction methods help reduce heat loss...

Страница 6: ...rnished with doors are considered a part of the uncon ned space Adjoining rooms are communicating only if there are doorless DETERMINING FRESH AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a...

Страница 7: ...rovide two perma nent openings one within 12 of the ceiling and one within 12 of the oor on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room...

Страница 8: ...ARNING Maintainthemini mumclearancesshowninFigure 4 page 9 If you can provide greater clearances from oor ceiling and joining wall You can recess rebox into the wall You can also position replace in t...

Страница 9: ...ble to Wall Minimum 16 inches from Side Wall Example 1 Frameinroughopening Usedimensionsshown in Figure 5 for the rough opening If installing in a corner use dimensions shown in Figure 6 for the rough...

Страница 10: ...rlap the rebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap the front facing but should never cover any necessary openings like louvered slots WARNING Do not allo...

Страница 11: ...ting plate shim in slot on mitered edge of side trim see Figure 9 6 While rmly holding edges of trim together tighten both set screws on the adjusting plate with slotted screwdriver 7 Repeat steps 1 t...

Страница 12: ...connection when servicingcontrols Wiringerrors cancauseimproperanddanger ous operation CAUTION Verify proper op eration after servicing Note If you are using a mantel with your heater use the followin...

Страница 13: ...5 9 Reconnect red wire to theAUTO switch posi tion Reconnect blue wire to the ON switch position Reconnect green and white wires to the power cord 10 Install the switch plate on the blower control shi...

Страница 14: ...nector not included Outlet Receptacle Strain Relief Blue Red 1 Install a snap bushing found in hardware kit into one of the holes found on rear of blower control shield The other hole is for a strain...

Страница 15: ...supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 inches of water If you do not reduce incoming gas pres...

Страница 16: ...valve from your dealer See Accessories page 35 Minimum inlet pressure for purpose of input adjustment 3 Minimum Gas Control Propane LP From External Regulator 11 W C to 14 W C Pressure Natural From Ga...

Страница 17: ...trol valve and equipment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where equipment shutoff valve was conne...

Страница 18: ...diagrams or failure to use only parts speci cally approved with this heater may result in property damage or personal injury CAUTION After installa tion and periodically thereafter check to ensure tha...

Страница 19: ...ne batteries Installing 9 Volt Battery in Receiver 1 Locate back of receiver under front burner of heater 2 Locate the battery clip mounted on the back of the receiver 3 Slide a 9 volt battery through...

Страница 20: ...re equipment shutoff valve is fully open 3 Set switch in OFF position WARNING Burner will come on automatically within one minutewhentheselectorswitch is in the ON position after the pilot is lit 4 Pr...

Страница 21: ...hrough 6 under Lighting Instructions page 20 2 Depress control knob and light pilot with match 3 Keep control knob pressed in for30 seconds after lighting pilot After 30 seconds release control knob N...

Страница 22: ...for any reason cannot transmit to the receiver the receiver will shut off the replace after 8 minutes Key Pad Lock Feature This feature allows the user to lock unlock the keypad on the hand held remo...

Страница 23: ...5 Figure 41 Correct Flame Pattern with Control Knob Set to High Flame Figure 42 Incorrect Flame Pattern with Control Knob Set to High Flame Approx 3 6 Above Top of Logs More Than 8 Above Top of Logs B...

Страница 24: ...utes 2 Inspect burner pilot and primary air inlet holes on injector holder for dust and dirt see Figure 43 3 Blow air through the ports slots and holes in the burner 4 Check the injector holder locate...

Страница 25: ...nd base panel 4 Replace ignitor cable 5 Replace piezo ignitor 6 Replace pilot assembly 7 Replace pilot assembly 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT positi...

Страница 26: ...ully open equipment shutoff valve 4 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 23 or replace ODS pilot assembly 5 Hand tighten until snug the...

Страница 27: ...e burners until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installation clearances see page 9 4 Clean burners see Cleaning and Maintena...

Страница 28: ...ro pane LP gas company 3 CleanODS pilot seeCleaning and Maintenance page 23 1 Locate and correct all leaks see Checking Gas Connec tions page 17 2 Replace control valve 1 Take apart gas tubing and rem...

Страница 29: ...Inlet Gas Pressure in of water Maximum 14 10 5 Minimum 11 5 Dimensions H x W x D Fireplace 25 7 8 x 27 x 13 3 4 25 7 8 x 27 x 13 3 4 Carton 28 x 26 13 16 x 16 1 2 28 x 26 13 16 x 16 1 2 Weight pounds...

Страница 30: ...tech com 113897 01A 30 ILLUSTRATED PARTS BREAKDOWN MODELS CF26PRA AND CF26NRA 10 24 25 O F F P I L O T O N H I L O O F F P I L O T O N H I L O 16 15 19 8 19 20 21 17 18 14 13 23 12 22 13 4 7 6 9 5 11...

Страница 31: ...80 01 102980 01 Burner 1 10 099387 13 099387 15 Pilot Tube 1 11 103781 02 103781 01 Gas Control Valve 1 12 103345 02 103345 02 Lower Bracket 1 13 M11084 38 M11084 38 Screw 8 x 38 7 14 104384 04 104384...

Страница 32: ...www desatech com 113897 01A 32 ILLUSTRATED PARTS BREAKDOWN MODELS CF26PRA AND CF26NRA 5 8 15 17 13 14 11 2 11 1 19 4 12 16 10 6 5 9 1 2 18 7 20 2 20 3 20 1 18 18 16 21 3 18 16 3 21...

Страница 33: ...er 1 8 105255 01 Bayfront Base 1 9 105421 01 Heat De ector 1 10 105409 01 Fan Control Shield 1 11 1 105401 01 Screen Rod 1 11 2 105440 01 Screen Assembly 1 12 101386 02 Hinge 2 13 099194 11 Rivets 8 1...

Страница 34: ...uestions about installation operation or troubleshooting If so contact DESA Heating Products Technical Service Department at 1 866 672 6040 When calling please have your model and serial numbers of yo...

Страница 35: ...g heater to be turned on and off by using a hand held remote control BRASS ACCENT TRIM GA7092 Not Shown Optional two piece trim kit for the Bayfront Fire place Easily screws to replace front Provides...

Страница 36: ...such other costs related to repairing a defective replace will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EX...

Отзывы: