background image

38

102665

ACCESSORIES

Purchase these fireplace accessories from your local dealer or Parts Central. If they
can not supply these accessories, call DESA International’s Sales Department at 1-
800-432-2382 for referral information. You can also write to the address listed on
the back page of this manual.

CABINET MANTEL
GMC11F (A) - Walnut Finished
GMC12U (A) - Unfinished

Mantel features moldings, fluted sides, and medal-
lion. Available in walnut finished or unfinished
hardwood, ready to stain or paint. Shown with
optional base accessory.
Dimensions (H xW xD): 44" x 57-3/4" x 22-7/8"

HEARTH BASE
GC3333F- Walnut Finished
GC3334U - Unfinished

The hearth base creates a handsome
riser for the fireplace . Dimensions
(H xW xD):  6-1/2" x  58" x 28-9/16"

MANUAL SHUTOFF
VALVE - GA5010

For all models. Manual shutoff valve with 1/8" NPT tap.
Fits 1/2" NPT pipe.

Note:

 Use only original replacement parts. This will protect your warranty cover-

age for parts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product. If they can’t supply original replace-
ment part(s), call DESA International’s Technical Service Department at
1-800-DESA LOG (1-800-337-2564).

When calling DESA International, have ready

• your name
• your address
• model number of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date

Usually, we will ask you to return the defective part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product or Parts Central. If they can’t supply
original replacement part(s), call DESA International’s Parts Department at 1-800-
972-7879 for referral information.

When calling DESA International, have ready

• model number of your fireplace
• the replacement part number

REPLACEMENT

PARTS

Содержание CGF265PVA

Страница 1: ...gency or the gas supplier WARNING Improperinstallation adjustment alteration service or maintenance can cause injury orpropertydamage Refertothis manual for correct installation and operational proced...

Страница 2: ...s The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exists Make certain you read and understand all Warnings Keep this manual for r...

Страница 3: ...ccur due to log curing and fireplace burning manufacturing residues 10 Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Ceiling fans can create d...

Страница 4: ...bly Figure 2 Fireplace Top Louvered Hood Bottom Louver Assembly Screen Assembly Top Outer Casing Firebox Support Side Access Door Rear Access Door Base Rear Burner Right Front Branch 5 Front Burner Fr...

Страница 5: ...ency back up heat Safety Features This fireplace has a pilot with an Oxygen Depletion Sensor Shutoff System ODS The ODS pilot is a required feature for vent free room heaters The ODS system protecta a...

Страница 6: ...2 Section 5 3 defines confined space as having an air volume of less than 50 cubic feet 127 cubic cm for each 1000 Btu Hr input rating of all appliances in the space cubic feet equals length x width x...

Страница 7: ...er ___________________ Btu Hr Gas fireplace logs ___________________ Btu Hr Other gas appliances ___________________ Btu Hr Total ___________________ Btu Hr Example Gas water heater 40 000 Btu Hr Vent...

Страница 8: ...of ventilation grills or ducts WARNING ICON G 001 WARNING Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in...

Страница 9: ...surfaces next to fireplace Installing fireplace next to vinyl or cloth wall coverings or operating fireplace where impurities in the air such as tobacco smoke exist may discolor walls IMPORTANT Vent f...

Страница 10: ...5 Slide other end of adjusting plate shim in slot on mitered edge of side brass trim see Figure 5 6 While firmly holding edges of brass trim together tighten both set screws on the adjusting plate wit...

Страница 11: ...the G3333F G3334U hearth base accessories The hearth base accessory shown is optional for this installation You can install fireplace and cabinet mantel directly on the floor 1 Assemble cabinet mantel...

Страница 12: ...flexible gas line to fireplace see Figure 9 Make sure to locate access hole so cabinet mantel will cover it when installed Note You can secure base to floor using wood screws Countersink screw heads...

Страница 13: ...this manner Height Front Width Depth Actual Framing Actual Framing Actual Framing 32 3 8 33 34 5 16 35 1 2 16 11 16 17 3 4 35 1 2 17 3 4 33 Figure 12 Rough Opening for Installing in Wall 1 Frame in r...

Страница 14: ...lace inside wall opening 4 Attach flexible gas line to fireplace gas regulator See Connecting Fireplace to Gas Supply page 17 5 Carefully insert fireplace into rough opening 6 Attach fireplace to wall...

Страница 15: ...external regulator not supplied Install the external regulator between the heater and propane LP supply Installation Items Needed Before installing fireplace make sure you have the items listed below...

Страница 16: ...pressure will occur WARNING ICON G 001 CAUTION Use pipe joint sealant that is resistant to liquid petroleum LP gas Install sediment trap in supply line as shown in Figure 17 page 17 Locate sedi ment...

Страница 17: ...wdriver sealant resistant to LP gas not provided 1 Remove fireplace screen Remove two screws that hold fireplace screen in place for shipping These screws are located near top of screen Discard screws...

Страница 18: ...eak Correct all leaks at once Flexible Gas Line from Fireplace Gas Regulator To Fireplace Gas Regulator 5 Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas lin...

Страница 19: ...e Figure 20 2 Open propane LP supply tank valve 3 Make sure control knob of fireplace is in the OFF position 4 Check all joints from manual shutoff valve to thermostat gas valve see Figure 21 Apply mi...

Страница 20: ...igure 22 2 Slide rear log 2 into place behind rear burner see Figure 23 3 Place left front branch 4 and right front branch 5 24 and 30 models or front branch 4 18 model into place see Figure 24 Make s...

Страница 21: ...your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a quali...

Страница 22: ...to the next step 5 Turn control knob counterclockwise C clockwise to the PILOT position Press in control knob for five 5 seconds see Figure 26 above Note If running fireplace for first time there will...

Страница 23: ...t After 30 seconds release control knob Now follow step 8 above OPERATING FIREPLACE Variable Manually Controlled Model CGF265PVA A This appliance has a pilot which must be lighted by hand When lightin...

Страница 24: ...five 5 seconds see Figure 28 above Note If running fireplace for first time there will be air in gas line You may need to press in control knob for 30 seconds or longer This will allow air to bleed fr...

Страница 25: ...heat output This results in increased heating comfort TO TURN OFF GAS TO APPLIANCE Shutting Off Fireplace 1 Turn control knob clockwise Clockwise to the HIGH position 2 Slightly depress control knob...

Страница 26: ...ont burner flame pattern Figure 33 shows incorrect front burner flame pattern The incorrect burner flame pattern shows yellow tipping at top of blue flame WARNING ICON G 001 WARNING If front burner fl...

Страница 27: ...broken or chipped dime sized or larger TROUBLE SHOOTING Note All troubleshooting items are listed in order of operation WARNING ICON G 001 WARNING Turn off fireplace and let cool before servicing Only...

Страница 28: ...S pilot see Cleaning and Mainte nance page 27 or replace ODS pilot assembly 6 Replace thermocouple 7 Replace control valve 8 Wait one minute for safety interlock system to reset Repeat ignition operat...

Страница 29: ...ntenance page 27 2 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burners until air is removed from...

Страница 30: ...ogged 1 Gas leak See Warn ing statement above 2 Control valve defective 1 Foreign matter be tween control valve and burner 2 Gas leak See Warn ing statement above 1 Not enough combus tion ventilation...

Страница 31: ...ounty Rd 400 E Valparaiso IN 46383 All States 219 462 7441 1 800 362 6951 Parts Department FBD P O Box 1096 1720 Kummer Road Franklin KY 42134 502 586 1922 1 800 654 8534 Four Flags Power Products 111...

Страница 32: ...2665 ILLUSTRATED PARTS BREAKDOWN Log Base Assembly Variable Manually Controlled Models CGF265PVA 4 5 27 8 9 8 8 19 13 12 8 6 2 1 7 7 1 7 2 10 18 23 16 11 26 14 6 6 6 6 21 15 19 3 29 24 30 20 28 31 25...

Страница 33: ...06 Ignitor Cable 1 14 101924 01CB Firebox Bottom 1 15 098867 10 Gas Regulator 1 16 101004 01 Front Burner Injector 1 17 097159 02 Piezo Ignitor 1 18 101007 01 Crossover Tube 1 19 099387 05 Pilot Tube...

Страница 34: ...34 102665 18 6 4 5 27 8 9 8 8 19 13 12 2 1 7 7 1 7 2 10 16 11 26 14 3 6 6 6 6 22 25 23 19 24 13 7 2 20 15 28 21 17 ILLUSTRATED PARTS BREAKDOWN Log Base Assembly Thermostat Controlled Models CGF280PT...

Страница 35: ...acket 1 10 101330 05 Front Burner Assembly 1 11 100999 02 Rear Burner Assembly 1 12 101392 02BR Base Assembly 1 13 098271 06 Ignitor Cable 1 14 101924 01CB Firebox Bottom 1 15 098867 10 Gas Regulator...

Страница 36: ...36 102665 ILLUSTRATED PARTS BREAKDOWN Fireplace 1 2 3 4 5 6 15 6 10 11 9 18 17 12 16 16 16 16 7 8 14 16 16 16 19 13 13 13...

Страница 37: ...ox Support 2 12 101347 01CB Outer Base 1 13 099230 02 Shoulder Screw 4 14 098304 01 Phillips Pan Head Screw 10 9 15 101872 03 Firebox Top 1 16 M11084 26 Hex Screw 10 63 17 101746 01 Handle 1 18 100587...

Страница 38: ...l shutoff valve with 1 8 NPT tap Fits 1 2 NPT pipe Note Use only original replacement parts This will protect your warranty cover age for parts replaced under warranty Parts Under Warranty Contact aut...

Страница 39: ...39 102665 NOTES...

Страница 40: ...and all such other costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHE PRODUCT THIS EXPRESS WAR...