background image

www.desatech.com

119668-01A

6

CLEANING AND 

MAINTENANCE

  WARNING: Always  discon-

nect power and allow the heater 

to  cool  before  performing  any 

cleaning, maintenance or reloca-

tion of this heater. Turn controls 

to  OFF  and  remove  plug  from 

outlet or turn off circuit breaker 

to heater.

Turn off heater and circuit breaker to heater before 

performing any cleaning and/or maintenance. Al-

low heater to cool completely.

bUlb RePlACeMeNT

 WARNING: The halogen light 

bulbs  in  your  unit  can  become 

extremely hot. Allow at least 10 

minutes between turning off the 

heater  and  removing  the  light 

bulbs to avoid accidental burns.

There are a total of 5 ( halogen light bulbs (type 

GX6.35 rated 120 volts, 35 watts) in your unit.

•  1 bulb provides illumination for the ember bed 

beneath the log set 

•  2  bulbs  provide  illumination  for  the  flame 

generation assembly

•  2 bulbs for replacement

Most halogen light bulbs are rated to last approxi-

mately 1800 hours. Like all light bulbs, halogen 

bulbs require periodic replacement. When the 

bulbs in your unit have burned out you will notice 

one or more of the following:

•  Flame is dim or dark in certain areas

•  Log set ember bed appears dim or dark in 

certain areas

  WARNING:  Do  not  install 

replacement bulbs that exceed 

specified maximum watts.

Your unit must be opened from the back in order 

to replace the flame generation bulbs. To replace 

the bulb under the ember bed you will open the 

unit in front. 

Replacing log Set ember bed bulb

1.  Turn knob and open door of stove.

2.  Push in and up on lower front panel. The panel 

slides into notches on front sides of stove as 

shown in Figure 5.

3.  Remove two screws securing grate. Remove 

grate.

4.  Hold log up away from bulb and carefully 

remove spring clip over bulb using needle 

nose pliers. Remove bulb.

5.  With log being held up away from socket, 

insert new bulb and carefully replace spring 

clip using needle nose pliers.

Replacing Flame Generation bulbs

1.  Unscrew  4  screws  from  louvered  back 

panel (see Figure 6). Remove louvered back 

panel.

Figure 5 - Ember Bed Bulb Location

Grate

Lower Front 
Panel

Bulb in Socket 
with Spring Clip

Log

Louvered 
Back 
Panel

Lower 
Back 
Panel

Figure 6 - Back of Stove

Back 
Control 
Panel

Содержание CGESBMRA

Страница 1: ...llow them could cause a heater malfunction resulting in serious injury and or property damage Save this manual for future reference For more information visit www desatech com 20 ELECTRIC STOVE WITH REMOTE CONTROL SAFETY INFORMATION AND OPERATION MANUAL Models CGESBMRA AND VESBMRA ...

Страница 2: ...d return it to an authorized service facility for examination electrical or mechanical adjust ment or repair 6 Do not use this unit outdoors 7 Do not use or install this unit in areas prone to dampness or where it may come into contact with water This heater is not intended for use in bathrooms laundry areas or other locations where water may be present 8 To reduce the risk of fire do not place or...

Страница 3: ...t outlet Always use ground fault protection where required by the electri cal code WARNING Do not operate the unit if it is damaged or has malfunctioned Ifyoususpectthe unit is damaged return the unit to an authorized service facility for examination electrical or me chanical adjustment or repair Frequency 60 Hz Heater Power 1500 W Heater Output 5000 BTUs Power Supply 120V 15 Amp Grounded Circuit ...

Страница 4: ...Turn this dial to adjust the flame intensity 4 Heater Switch and Control Dial The heater switch has a sun directly below it To turn the heater on flip Heater Switch to ON position indicates ON and O indicates OFF The Control Dial has a thermometerbelow it Turn dial clockwise past the number 8 You should hear a small clicking sound indicat ing the heater has started and heat will emit throughventsl...

Страница 5: ...N OFF button once When you hear the beep the fireplace will be completely off and the flame will disappear When you restart the fireplace with the remote control all of the features you had set will remain in effect NOTICE This remote control must remain within 26 feet 8 m of the fireplace to be effective IMPORTANT If flame does not activate after POWER ON OFF button is pressed press DISPLAYON OFF...

Страница 6: ...eplacement When the bulbs in your unit have burned out you will notice one or more of the following Flame is dim or dark in certain areas Log set ember bed appears dim or dark in certain areas WARNING Do not install replacement bulbs that exceed specified maximum watts Your unit must be opened from the back in order to replace the flame generation bulbs To replace the bulb under the ember bed you ...

Страница 7: ...ove spring clip Hold socket and pull out old bulb 5 Hold socket and push in new bulb DO NOT exceed wattage Replace spring clip 6 Repeat steps 3 and 4 for second bulb 7 Insertbottomedgeofremovedcylinderhalfinto bottom drum track Gently squeeze drum cylin der until it s top edge fits into top drum rack 8 Replace louvered back panel Replacing Glass 1 Remove top of stove by sliding top toward the back...

Страница 8: ...A Heating Products have ready model number of your heater the replacement part number 4 Slide heater assembly out back of stove and set aside see Figure 10 page 7 5 Slide glass up through top of stove 6 Slide new glass into place between glass retainers 7 Replace heater blower assembly using screws removed in step 3 page 7 8 Replace back control panel using screws removed in step 2 page 7 9 Slide ...

Страница 9: ...rs Remote control does not work Heater does not provide heat when turned on 1 Reset switch by turning main power switch off and waiting 5 minutes then turning it back on reset home circuit breaker or replace fuse 1 Inspect wiring for loose con nections 2 Call a qualified service techni cian to replace flame motor 1 Inspect bulbs and replace if necessary 2 Inspect wiring for loose con nections and ...

Страница 10: ...www desatech com 119668 01A 10 Illustrated Parts Breakdown Models CGESBMRA AND VESBMRA 1 2 13 14 15 6 16 9 8 5 10 11 12 7 4 3 ...

Страница 11: ...1 Control Board 1 3 117697 01 Flame Motor 1 4 117696 01 Flame Cylinder Assembly 1 5 117690 01 Log 1 6 117704 01 Rear Glass Mirror 1 7 119663 01 Front Door Assembly 1 8 119666 01 Heater Vent Front Panel 1 9 119665 01 Bottom Front Panel 1 10 117754 01 Light Bulb Sockets 2 11 117695 01 Bulb 3 12 117706 01 Legs 4 13 119669 01 Back Control Panel 1 14 119670 01 Back Louvered Panel 1 15 119671 01 Lower B...

Страница 12: ... fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY ...

Отзывы: