OPTIONAL HAND-HELD

 

REMOTE OPERATION

Note:  All  remote  control  accessories  must 
be  purchased  separately  (see Accessories, 
page  38).  Follow  instructions  included  with 
the remote control. 

NOTICE: You must light the pilot 

before using the hand-held re

-

mote control unit. See 

Lighting 

Instructions

 on page 22.

After  lighting,  let  pilot  flame  burn  for  about 

one  minute.  Turn  control  knob  to  ON  posi-

tion. Adjust flame adjustment knob anywhere 
between HI and LO. Slide the selector switch 

to  the  REMOTE  position  (see  Figure  39). 

Note: The burner may light if hand-held re-
mote was on when selector switch was last 
turned off. You can now turn the burner on and 
off with the hand-held remote control unit.
IMPORTANT:

 Do not leave the selector switch 

in the REMOTE or ON position when the pilot 
is not lit. This will drain the battery.

ON/OFF SERIES (MODEL HRC100)

Hold  the  control  button  on  the  hand-held 
remote  until  burner turns on. Hold  the con-
trol  button  again  until  burner  turns  off  (see 
Figure 40).

To  Lock

  press  both  buttons  on  hand-held 

remote control until light stops flashing. Hand-
held remote control is now locked. If the fire 
is on it will be turned off automatically. In the 
locked state, the light will not light up when 

any button is pressed. 

To  Unlock

  press  both  buttons  together 

on  hand-held  remote  control  until  the  light 

stops flashing. The hand-held remote is now 

unlocked.

THERMOSTAT SERIES (MODEL 
HRC200)

The hand-held remote can be operated using 
either the manual mode (MANU) or thermo-
static mode (AUTO) (see Figure 41). To select 

Fahrenheit/Centigrade mode display, carefully 
press the ˚C/˚F mode button with the end of a 

paper clip or similar blunt object.

Figure 39 - Setting the Selector Switch, 

Control Knob and Flame Adjustment 

Knob for Remote Operation 

Flame 

Adjustment Knob

Control 

Knob

Selector Switch in Remote

Position (Optional Remote Control)

Figure 41 - Thermostat Hand-Held 

Remote Control Unit 

Manual Mode

1.  Press  the  POWER  and  LOCK  buttons 

together to turn on the hand-held remote 
control.

2.  Press  the  MANU  button  to  turn  on  the 

fireplace.

3.  Press  the  POWER  and  LOCK  buttons 

together to turn off the fireplace.

Figure 40 - ON/OFF Hand-Held Remote 

Control Unit

Control 
Button

Indicator 
Light

LOCK

MANU

AUTO

ºC/ºF

TEMP

POWER

ROOM
TEMP

SET
TEMP

AUTO

Turns 
Hand-Held 
Remote On 
or Off and 

Allows You 

to Choose 
the Manual 
Setting

Selects 
AUTO 
Mode

°C/°F 
Mode 
Button

Locks 
System to 
Prevent 
Accidental 
Ignition

Turns 
Burners 
On or 
Off

Increases or 
Decreases 
Room 
Temperature 
in AUTO Mode

Digital Display Shows 

Temperature and Settings

opERaTioN 

Continued

REmoTE-REaDy moDEls

Содержание CDCFNRA

Страница 1: ...sonal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas su...

Страница 2: ...icated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING This product contains and or generates chemicals known to the State of California to cause cancer or birth defects or other reproduc tive harm IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble o...

Страница 3: ...ould be located out oftrafficandawayfromfurniture and draperies Do not place clothing or other flammable material on or near the appliance Never place any objects on the heater Fireplace front and screen be come very hot when running heater Keepchildrenandadults away from hot surfaces to avoid burns or clothing ignition Fire place will remain hot for a time after shutdown Allow surfaces to cool be...

Страница 4: ...to run properly This fireplace has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the fire place if not enough fresh air is available See Air for Combustion and Ventilation page 6 If fireplace keeps shutting off see Troubleshooting page 27 11 Do not run fireplace where flammable liquids or vapors are used or stored under dusty conditions 12 Do not use this fireplace to co...

Страница 5: ...s tem requires no matches batteries or other sources to light fireplace Thermostatic Heat Control for thermostat Controlled Models Thermostat Controlled models have a ther mostat sensing bulb and a control valve The thermostat will automatically modulate the heat output to maintain a consistent room temperature This results in greater fireplace comfort This can also result in lower gas bills Unpac...

Страница 6: ...al codes Read the following instructionstoinsureproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods help reduce heat loss in homes Home owners weather WARNING Always have screeninplacebeforeoperating fireplace This prevents exces sive temperatures on fireplace...

Страница 7: ...ooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them DETERMINING FRESH AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this work shee...

Страница 8: ...fined space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 5 You can also remove door into adjoining room see option 3 Figure 5 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required si...

Страница 9: ...gulator supplied by installer for propane LP units only piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection ground joint union sediment trap tee joint pipe wrench ACSAdesign certifiedequipmentshutoffvalve with 1 8 NPTtap is an acceptable alternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve fro...

Страница 10: ...from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 6 Example The face of a mantel bookshelf etc is made of combustible material and protrudes 3 1 2 from the wall This com bustible material must be 4 from the side of the fireplace opening see Figure 7 INSTALLATION Continued Figure 7 Minimum Clearance for Combustible to Wall Minimum 16 from Si...

Страница 11: ...combustible materials such as wall board gypsum board sheet rock drywall plywood etc may be butted up next to the sides and top edge of the firebox Combustible materi als should never overlap the firebox front facing Figure 9 Rough Opening for Installing in Corner Figure 8 Rough Opening for Installing in Wall 435 16 305 8 611 4 267 8 Figure 10 Attaching Fireplace to Wall Studs Nailing Flanges Nail...

Страница 12: ...nationalproductstandard Follow all minimum clearances shown in this manual INSTALLATION Continued Figure 11 Minimum Mantel Clearances for Built In Installation Mantel Shelf Side of Firebox NOTICE Ifyourinstallationdoes not meet the minimum clear ances shown you must do one of the following raise the mantel to an accept able height remove the mantel Removing Upper Louver To install mantel or blower...

Страница 13: ...no greater than 14 of water If gas line pressure is higher heater regulator damage could occur CAUTION Neverconnectpro pane LP fireplace directly to the propane LPsupply Thisfireplace requires an external regulator notsupplied Installtheexternal regulator between the fireplace and propane LP supply For propane LP units the installer must supply an external regulator The external regulator will red...

Страница 14: ... sealant lightly to male threads of gas connector attached to flexible gas line equipment shutoff valve see Figure 16 CAUTION Avoid damage to regulator Holdgasregulatorwith wrenchwhenconnectingittogas piping and or fittings Thermo stat Controlled Models Only CAUTION Avoid damage to gas control Hold gas control with wrench when connecting it to gas piping and or fittings Remote Ready Models Only Fi...

Страница 15: ...gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter to equip ment shutoff valve for natural gas or pro pane LP supply to equipment shutoff valve for propane LP see Figures 18 or 19 Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once Pressure Testing Fireplace G...

Страница 16: ...Terminal Wires Figure 22 Installing Remote Receiver Remote Receiver White Wire to TH Terminal on Control Valve Red Wire to TPTH Terminal on Control Valve Optional Wall Mounted Thermostat GWMT1 Remote Ready Models Only WARNING Read and fol low installation instructions Installation should be done by a qualified installer familiar with low voltage wiring procedures WARNING Do not connect this thermo...

Страница 17: ...witch to any electrical source Electrical shock and or fire hazard will occur 1 Remove jumper wire from control valve see Figure 20 page 16 2 Connect one terminal of 25 ft wire to the TH terminal on the control valve Con nect other terminal to the THTP terminal on control valve See Figure 24 3 Route the 25 ft wire to a convenient loca tion to mount your wall switch no outside walls WARNING Do not ...

Страница 18: ... louver Figure 28 Installing Rear Brick Liner Figure 29 Installing Side Brick Liners Figure 30 Installing Log Left Brick Liner Brick Liner Bracket and Screw Rear Brick Liner Log Set 2 Place rear brick liner against back of fire box The left and right brick liners will hold this liner in place see Figure 28 Be sure to hold the rear brick liner while installing the sides so it will not fall forward ...

Страница 19: ...l injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch ...

Страница 20: ...place has a safety inter Operation Continued Thermostat Controlled Models Figure 32 Control Knob In The OFF Position Ignitor Button Control Knob Figure 33 Natural Gas Pilot Thermocouple Ignitor Electrode Pilot Burner Figure 34 Propane LP Gas Pilot Thermocouple Ignitor Electrode Pilot Burner TO TURN OFF GAS TO APPLIANCE Shutting Off Fireplace 1 Turn control knob clockwise to the OFF position 2 Turn...

Страница 21: ...a few hours WARNING Burner will come on automatically within one min ute when control valve is in the ON position after the pilot is lit Note Your fireplace and thermostat blower will not turn on and off at the same time The fireplace may run for several minutes before the blower turns on After the heater modulates to the pilot position the blower will continue to run The blower will shut off afte...

Страница 22: ...ntact a qualified service person or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 8 Slightly push in and turn control knob coun terclockwise to the ON position 9 Set flame adjustment knob to any level between HI and LO Figure 36 Control Knob and Ignitor Button Location Shown as Supplied No Control Options Piezo Ignitor Button Control Knob Flame Adjustment Knob Figure 37 ...

Страница 23: ...ed state the light will not light up when any button is pressed To Unlock press both buttons together on hand held remote control until the light stops flashing The hand held remote is now unlocked Thermostat Series Model HRC200 The hand held remote can be operated using either the manual mode MANU or thermo static mode AUTO see Figure 41 To select Fahrenheit Centigrade mode display carefully pres...

Страница 24: ...emperature If the hand held remote is misplaced obstructed or for any reason cannot transmit to the receiver the receiver will shut off the fireplace This will occur in 8 or more minutes depending upon location of remote transmitter and strength of batteries Key Pad Lock Feature This feature allows the user to lock unlock the keypad on the hand held remote in the MANU or AUTO mode to prevent inadv...

Страница 25: ...e Note When using the fireplace the first time the flame will be orange for approximately one hour until the log cures If burner flame pattern is incorrect as shown in Figure 45 turn fireplace off see To Turn Off Gas toAppli ance page20forThermostat ControlledMod els or page 22 for Remote Ready Models see Troubleshooting page 27 Figure 44 Correct Burner Flame Pattern Figure 45 Incorrect Burner Fla...

Страница 26: ...ow been pushed into the burner repeat steps 3 and 4 Clean the pilot assembly also A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air CLEANING AND MAINTENANCE Continued LOG Set If you remove one piece log set for clean ing refer to page 18 for placement instruc tions Replace log set if broken or chipped dime sized or larger CABINET Air Passagewa...

Страница 27: ...e in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace pilot assembly 6 Replace pilot assembly 1 Turn on gas supply or open equipm...

Страница 28: ...er ODS pilot lights keep control knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 25 or replace ODS pilot assembly 6 Hand tighten until snug then tighten 1 4 turn more 7 Replace pilot assembly 8 Repl...

Страница 29: ...rn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observeminimuminstallation clearances see page 10 4 Clean burner see Cleaning and Maintenance page 25 or replace burner orifice 1 Turn fireplace off when using furniture polish wax carpet cleaners or similar products 1 Refer to Air for Com...

Страница 30: ...k See Warning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page REMEDY 1 Open window to venti late room Stop using odor causing products while fireplace is running ...

Страница 31: ...l information A list of authorized dealers can be found by visiting www desatech com When calling DESA Heating LLC have ready model and serial numbers of your heater the replacement part number Replacement Parts Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Parts Under Warranty Contact authorized dealers of this product If they ...

Страница 32: ...3502 01C 32 8 10 8 14 14 14 14 14 14 14 1 9 9 10 19 19 20 10 16 17 10 6 3 11 12 13 21 19 22 11 15 16 18 16 16 16 16 16 16 2 5 16 16 16 16 7 4 10 23 Parts Firebox Models CDCFPRA CDCFNRA VDCFRPB VDCFRNB VDCFTNB and VDCFTPB ...

Страница 33: ...Hinge 1 13 104313 02 Left Pin Hinge 1 14 099230 02 Screw HWH SHLDR AB 10 x 0 63 14 15 111038 02 Remote Blower Bracket 1 16 M11084 26 Screw HWH AB 10 16 x 0 38 35 17 111633 01 Box Cover 1 18 111200 01 Support Bracket 1 19 116472 01 Brick Liner Kit 1 20 114408 01 Retainer 2 21 105440 01 Screen Assembly 1 22 103452 03 Screen Rod 2 23 103295 05BR Screen Frame 1 Not a field replacement part Parts Fireb...

Страница 34: ...www desatech com 123502 01C 34 Parts THERMOSTAT MODELS VDCFTPB and VDCFTNB 8 7 5 6 6 12 2 4 19 18 15 16 9 9 17 11 14 3 13 20 9 1 21 10 ...

Страница 35: ... AB 8 18 x 0 38 2 9 M11084 26 Screw HWH AB 10 16 x 0 38 10 10 Chamber Floor 1 11 097809 02 Male Fitting 1 12 098867 10 Gas Regulator 1 098867 14 Gas Regulator 1 13 108628 02 Inlet Tube 1 14 102394 02 Control Bracket 1 15 098522 13 Thermostat Gas Valve 1 098522 12 Thermostat Gas Valve 1 16 101381 01 Valve Cover with Piezo 1 17 101628 03 Flexible Connector 1 18 099211 01 Screw HWH AB 10 16 x 2 50 2 ...

Страница 36: ...www desatech com 123502 01C 36 Parts REMOTE READY MODELS CDCFNRA CDCFPRA VDCFRNB and VDCFRPB 16 15 15 16 12 12 11 9 9 9 10 5 17 18 13 19 2 1 4 3 14 7 6 8 20 Natural Gas Only 9 21 22 ...

Страница 37: ...98249 01 ODS Nut 2 9 M11084 26 Screw HWH AB 10 16 x 0 38 10 10 Chamber Floor 1 11 110793 01 Piezo Bracket 1 12 102445 01 Piezo Ignitor with Palnut Fastener 1 13 101628 01 Flexible Connector 1 14 098271 10 Ignitor Cable 1 15 M12461 26 Screw MX SLT WSR 10 32 x 3 8 4 16 111173 01 Remote Valve Bracket 2 17 103781 02 Gas Valve 1 103781 01 Gas Valve 1 18 101480 12 ASM High Temp Wire 1 19 097809 02 Male ...

Страница 38: ...as needed CORNER MANTEL WITH Full HEARTH BASE GMC83F Oak Finished Georgian Design CS26CP Black Red Oak Cottage Design CMA208FB Light Oak Finished Traditional Design For all models Space saving mantel and hearth base corner design features clean classic lines Complete assembly instruc tions included Three sided perimeter trim kit included CABINET MANTEL and full hearth base GMC80FA Light Oak Finish...

Страница 39: ... care and maintenance video is available by calling 1 866 672 6040 You may also email your request to productsupport desaint com Brick Liners Series 3 Included with CDCF Models HFL200 Aged Almond Straight Brick Pattern HFL201 Aged Red Straight Brick Pattern For all models Allows firebox interior to be aesthetically enhanced WALL MOUNT THERMOSTAT SWITCH GWMT1 For all models The desired comfort sett...

Страница 40: ..._____________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________________________ Keep receipt for warranty verification DESA Heating LLC 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com 123502 01 ...

Отзывы: