MOUNTING AND CONNECTING SWITCh

1.  Remove  2  connectors  from  ON/OFF  rocker  switch  located  on  wiring 

harness. See Figure 5.

2.  Insert rocker switch into lower louver panel with switch lever pointing 

outward.

3.  Reconnect previously removed wire connectors onto switch terminals.
4.  Insert supply plug into one of the available power receptacles at the right 

side of compartment. See Figure 5.

IMPORTANT: Be sure to inspect components and wiring for damage before 
restoring power to appliance. If damaged, contact an authorized dealer for 
original replacement part(s) or call DESA Heating, LLC at 1-866-872-6040 
for referral.

Power Receptacle

Figure 5 - Connecting Switch and Supply Plug

Blower Supply Plug

Wire Connectors

Blower Rocker Switch

COMPLETING INSTALLATION

1.  Reinstall  louver  panel  (if  equipped)  into  framed  opening  with  louvers 

pointing upward.

2.  Apply  wiring  diagram  label  (shown  in  Figure  6)  to  control  cover  and 

replace cover back over compartment opening.

3.  Reinstall front refractory panel and glass doors in reverse order shown 

in Figure 2, page 1.

4.  To operate, turn rocker switch to the ON position.

Figure 6 – Wiring Diagram