108998-01E

2

The BK and BKT blowers utilize the same rotary 

squirrel cage type blower with magnetic attach-

ment and variable speed control. The BKT also 

includes an additional thermostatically controlled 

feature for use on some direct-vent models only.

The BK blower can be installed in wood burning, 

B-vent and vent-free model fireplaces. Both the 

BK and BKT blowers can be installed in direct-

vent model fireplaces. Blowers are installed by 

accessing the blower compartment through the 

lower louver panel or, on some models, through 

the control access cover under the front refractory 

panel (see Figure 1). The lower front louver panel 

can be removed easily, see 

Removing Louver 

Panel,

 page 3 for instructions.

Figure 1 - Accessing Blower Compartment (Controls Not 

Shown for Clarity) B-Vent, Wood and Vent-Free Models

Front Refractory 
Panel

Lower 
Louver 
Panel

Control 

Access 

Cover

Knockout 
Plug

Figure 2 - Accessing Duplex Electrical Outlet Installed in 

Bottom Right Side of Firebox

Duplex 
Electrical 
Outlet

 WARNING: If there is a du-

plex electrical outlet installed in 

the right side of the bottom of 

the fireplace base area (see Fig

-

ure 2), be sure that the electrical 

power to the outlet is turned off 

before proceeding with blower 

installation. Failure to do this 

may result in serious injury.

Содержание BK

Страница 1: ...ck Nut 1 11125 8 1 2 Phillips Head Screw 1 101378 01 Thermodisc Switch 100 Limit 1 104902 02 Switch Mounting Bracket 1 109892 01 Speed Control Bracket Stamped Face Models 1 109892 02 Speed Control Bracket Panel Louver Models 1 Tools Required Pliers Phillips Screwdriver Flat Blade Screwdriver If any of these pieces are missing or damaged or if the installation instructions for your fireplace or sto...

Страница 2: ...rough the control access cover under the front refractory panel see Figure 1 The lower front louver panel can be removed easily see Removing Louver Panel page 3 for instructions Figure 1 Accessing Blower Compartment Controls Not Shown for Clarity B Vent Wood and Vent Free Models Front Refractory Panel Lower Louver Panel Control Access Cover Knockout Plug Figure 2 Accessing Duplex Electrical Outlet...

Страница 3: ...le embossed on the edge of the panel To reinstall place louver into cavity and push gently Direct Vent Models There are two different types of direct vent lou vers spring latch and bullet style clip Spring Latch Remove louver with spring latches by simultaneously pulling both top spring latches toward the center of the appliance until they are disengaged from the locating holes Repeat for bottom s...

Страница 4: ...ach and make all connections DO NOT trim excessive length away Just enable enough to make all connections securely Figure 5 Blower Model BK Magnetic Strips Exhaust Port Screw Green Ground Wire Spade Terminals Side View Firebox Bottom Air Flow Direction Blower Installed After Lower Panel Removed Blower Location Magnets Model BK wire assembly Note Speed control switches can not be installed into fil...

Страница 5: ...ol shaft see Figure 8 Speed Control Bottom Rear Refractory 3 Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward and the thermodisc positioned up near the fireplace bottom The thermodisc must be oriented near the fireplace bottom as shown in Figure 6 in order to sense temperature and properly operate The blower will be held in position ag...

Страница 6: ...peed control to bracket with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against bracket Figure 9 Attaching Speed Control to Firebox with Stamp Faced Louvers B36 and VB36 Models Using Speed Control Bracket 109892 01 Lock Nut Mounting Speed Control Continued 3 Remove knockout plug from louver panel by depressing top and bottom retaining clips see Figure 1 page 2...

Страница 7: ...ing knob fully counterclockwise before continuing BKT Model The blower will only run when the speed control knob is in the ON position and the thermal switch senses temperature after the fireplace begins to heat up The blower speed can be adjusted by rotating the control knob To turn off turn knob fully counterclockwise until it clicks off If the blower is ON and has been running with the fireplac...

Страница 8: ...108998 01 Rev E 10 05 NOT A UPC 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Technical Service Department 1 866 672 6040 www desatech com 108998 01 ...

Отзывы: