Desa BCLP155 Скачать руководство пользователя страница 10

10

100170

Ignitor

Make sure gap between
ignitor electrode and burner
nozzle is 3,3 to 3,81 mm
(.13/.15"). Access ignitor
electrode from inside combus-
tion chamber. No other
maintenance is needed for
ignitor.

Burner Nozzle

Figure 9 - Gap Between Ignitor Electrode and Burner Nozzle

Ignitor Electrode

.13/.15" Gap

Model

RCLP155 and BCLP155

Input Rating

158.250 kJ/Hr (150,000 BTUHr)

Fuel

Propane Vapor Only

Fuel Consumption

Liters/Hour (Gallons/Hour)

6,7 (1.6)

Kilos/Hour (Pounds/Hour)

3,15 (7.0)

Supply Pressure To Regulator

Minimum (for purposes of input adjustment)

69 kPa (10 psi)

Maximum

Tank Pressure

Regulator Outlet Pressure (Factory Preset)

31,75 (12.5") WC

Manifold Pressure

9.8 po (9.8") WC

Motor

3.400 tr/min 1/8 CV
(3,400 RPM, 1/8 HP)

Electric Input

120 V/60 Hz

Amperage

2.2

Ignitor Gap

3,3 to 3,81 mm (.13/.15 in.)

Weight

Heater

11,2 kg (24 lbs.)

Shipping

15,8 kg (35 lbs.)

Size - L x W x H

95 cm x 36 cm x 53 cm
(37

1

/

2"

 x 14

1

/

2"

 x 21")

SPECIFICATIONS

Motor

 Burner
Control

Solenoid

Valve

Ignitor

Green

Blue

Blue

White

Red

Terminal

Board

Black

Yellow

Black

Green

White

Blue

T

Blue

Green

Connector

Blue

Connector

Relay

Thermal

Switch

Start

Switch

Power

Cord

Yellow

Yellow

Black

White

Red

Black

White

Red

4

3

2

1

6

5

8 7

Orange

Blue

Orange

Black

Motor Start

Relay

“S” or “2”

“M” or “3”

“L” or “1”

WIRING

DIAGRAM

Содержание BCLP155

Страница 1: ...OPANE CONSTRUCTION HEATERS IMPORTANT Read and understand this manual before assembling starting or servicing heater Improper use of heater can cause serious injury Keep this manual for future reference Models RCLP155 and BCLP155 ...

Страница 2: ...hooting 8 Maintenance 8 Storage 8 Service Procedures 9 Wiring Diagram 10 Specifications 10 Accessories 11 Technical Service 11 Service Publications 11 Replacement Parts 11 Warranty and Repair Service Back Cover SECTION PAGE CONTENTS FOR YOUR SAFETY Do not use this heater in a space where gasoline or other liquids having flammable vapors are stored or used ...

Страница 3: ...ot use a damaged heater Use only propane gas set up for vapor withdrawal Keep propane tank s below 38 C 100 F Use only in well vented areas Provide at least a 0 28 m2 three square foot opening of fresh outside air for each 105 500 kJ hr 100 000 BTU Hr of rating Use only in places free of flammable vapors or high dust content Keep heater away from strong drafts water spray rain or dripping water Us...

Страница 4: ... Start Switch Figure 1 RCLP155 and BCLP155 Models UNPACKING 1 Remove all packing items applied to heater for shipment Keep plastic cover caps attached to inlet connector and hose regulator assembly for storage 2 Remove all items from carton 3 Check all items for shipping damage If heater is damaged promptly inform dealer where you bought heater ...

Страница 5: ...r only with a propane vapor withdrawal supply system The amount of propane gas ready for use from propane tanks varies Two factors decide this amount 1 The amount of propane gas in tank s 2 The temperature of tank s The chart below shows the number of 45 kg 100 pound tanks needed to run this heater Do not operate this product with any tank smaller than 45 kg 100 pounds Clean Heated Air Out Front C...

Страница 6: ...ation Section page 3 They are needed to safely operate this heater Follow all local codes when using this heater WARNING Test all gas piping and connections for leaks after installing or servicing Never use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming show a leak Correct all leaks at once Figure 3 Regulator With Vent Pointing Down 3 Conne...

Страница 7: ...l codes when using this heater Extension Cord Size Requirement Up to 15m 50 feet long use 18 AWG rated cord 15 5 to 30 5 51 to 100 feet long use 16 AWG rated cord 31 to 61 M 101 to 200 feet long use 14 AWG rated cord 4 Plug extension cord into a 120 volt 60 hertz three hole grounded outlet 5 Open propane supply valve on propane tank s slowly Note If not opened slowly excess flow check valve on pro...

Страница 8: ... CAUTION Disconnect heater from propane supply tank s STORAGE TROUBLE SHOOTING If heater does not start or restart Check manual valves if any and supply valves on propane tank Make sure they are open Check fuel level in propane tank s If fuel level is too low contact local propane gas company If heater still does not start or restart contact your local service center MAINTENANCE WARNING Never serv...

Страница 9: ... fan pitch 1 Remove upper shell by removing the screws along each side of heater using 7 8 mm 5 16 nut driver see Figure 5 These screws attach upper and lower shells together 2 Lift or slide upper shell off 3 Remove fan guard 4 Use 3 17 mm 1 8 Allen wrench to loosen setscrews which hold fan to motor shaft see Figure 7 5 Slip fan off motor shaft 6 Clean fan using soft cloth moistened with kerosene ...

Страница 10: ...input adjustment 69 kPa 10 psi Maximum Tank Pressure Regulator Outlet Pressure Factory Preset 31 75 12 5 WC Manifold Pressure 9 8 po 9 8 WC Motor 3 400 tr min 1 8 CV 3 400 RPM 1 8 HP Electric Input 120 V 60 Hz Amperage 2 2 Ignitor Gap 3 3 to 3 81 mm 13 15 in Weight Heater 11 2 kg 24 lbs Shipping 15 8 kg 35 lbs Size L x W x H 95 cm x 36 cm x 53 cm 371 2 x 141 2 x 21 SPECIFICATIONS Motor Burner Cont...

Страница 11: ...r address model number of your heater how heater was malfunctioning purchase date In most cases we will ask you to return the defective part to the factory Parts Not Under Warranty Contact authorized dealers of this product If they cannot supply original replace ment part s call DESA Industries Parts Department at 905 826 8010 When calling DESA Industries have ready model number of your heater the...

Страница 12: ...o not allow the exclusion or limitation of incidental or consequential damages These limitations or exclusions may not apply to you This Limited Warranty gives you specific legal rights and you may also have other rights which vary from province to province To be filled in by purchaser WARRANTY SERVICE Should your heater require service return it to your nearest authorized service center Proof of ...

Отзывы: