background image

111162-01B

13

13

For more information, visit www.desatech.com

For more information, visit www.desatech.com

Pressure Testing Heater Gas Connections

1.

Open equipment shutoff valve (see Figure 20).

2.

Open main gas valve located on or near gas meter for natural
gas or open propane/LP supply tank valve.

3.

Make sure control knob of heater is in the OFF position.

4.

Check all joints from equipment shutoff valve to control valve
(see Figure 21 or 22). Apply  a noncorrosive leak detection
fluid to gas joints. Bubbles forming show a leak.

5.

Correct all leaks at once.

6.

Light heater (see Operating Heater, pages 13 through 17).
Check all other internal joints for leaks.

7.

Turn off heater (see To Turn Off Gas to Appliance, page 14).

INSTALLATION

Continued

Figure 20 - Equipment Shutoff Valve

Equipment
Shutoff Valve

Figure 21 - Checking Gas Joints (Amity™ Stove Model Shown)

ON

POSIT

O

POS

Closed

Open

Control Valve Location

Propane/LP
Supply Tank

Equipment Shutoff Valve

Figure 22 - Checking Gas Joints (Amity™ Stove Model Shown)

Gas Meter

Equipment
Shutoff Valve

Control Valve Location

OPERATING HEATER

FOR YOUR SAFETY

READ BEFORE LIGHTING

 WARNING: If you do not follow these instructions

exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by hand.

When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area

for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in

your building.

• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas control knob.

Never use tools. If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified service techni-
cian or gas supplier. Force or attempted repair may result
in a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation of new heater, burn-
ing logs will give off a paper-burning smell. Open
window to vent smell. This will only last a few hours.

1.

STOP! Read the safety information above.

2.

Make sure equipment shutoff valve is fully open.

3.

Set switch to OFF position.

 WARNING: Burners will come on automatically

within one minute when the remote selector switch is
in the ON position after the pilot is lit.

4.

Press in and turn control knob clockwise 

  to the

OFF position.

INSTALLATION

Checking Gas Connections (Cont.)

OPERATING HEATER

For Your Safety Read Before Lighting

Lighting Instructions

Содержание Amity

Страница 1: ...ualified installer service agency or the gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause injuryorpropertydamage Refertothismanual for correct installa...

Страница 2: ...g WARNING Anychangetothisheateroritscontrols can be dangerous WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Ceiling fans can create dr...

Страница 3: ...ater needs fresh outside air ventilation to run properly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Ai...

Страница 4: ...ually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide a...

Страница 5: ...the outdoors Example Gas water heater _____________ Btu Hr Vent free heater _____________ Btu Hr Total _____________ Btu Hr WARNING If the area in which the heater may be operated is smaller than tha...

Страница 6: ...Code ANSI Z223 1 NFPA 5 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic ha...

Страница 7: ...clearances If you can provide greater clearances from floor ceil ing and adjoining side and back walls Carefully follow the instructions below This stove is a freestanding unit designed to set directl...

Страница 8: ...from inside stove cavity Contents include 1 Stove bottom 4 Legs Amity and Victor Hearth models include leg leveler bolts 1 Bottom door 1 Top grate 1 Hardware kit bag with fasteners 6 Carefully lay sto...

Страница 9: ...er stove is in normal standing position 13 Carefully lift stove back up on its four attached legs 14 Set top grate into stove top 15 If available install gas log heater inside stove cavity before inst...

Страница 10: ...se mounting hole and through stove bottom Connect hex nut to bolt on underside of stove bottom The bolt hex head is for a 5 16 socket and the hex nuts are for a 3 8 socket If sockets are not available...

Страница 11: ...r connect propane LP heater di rectly to the propane LP supply This heater requires anexternalregulator notsupplied Installtheexternal regulator between the heater and propane LP supply WARNING This a...

Страница 12: ...leaks after installing or servicing Correct all leaks at once CHECKING GAS CONNECTIONS Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance wit...

Страница 13: ...ly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not...

Страница 14: ...e away from home for long periods of time Heater will come on automatically with selector switch in the ON position OPERATING HEATER Continued O F F P I L O T O N L O IH AUTO OFF ON Figure 23 Control...

Страница 15: ...fullypress the C F mode button with the end of a paper clip or similar blunt object Manual Mode 1 Press the POWER and LOCK buttons together to turn on the hand held remote control 2 Press the MANU but...

Страница 16: ...njector Holder and Pilot Air Inlet Hole Figure 30 Injector Holder On Outlet Burner Tube Burner Tube Injector Holder Primary Air Inlet Holes CLEANING AND MAINTENANCE WARNING Turn off heater and let coo...

Страница 17: ...cated at the end of the burner tube again Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector hold...

Страница 18: ...onnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace pilot assembly 6 Replace pilot assembly 1 T...

Страница 19: ...pane LP or natural gas company 3 Observe minimum installation clear ances see page 7 4 Clean burner see Cleaning and Main tenance pages 16 and 17 or replace burner orifice 1 Properly locate logs see I...

Страница 20: ...g noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1...

Страница 21: ...h com REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this prod...

Страница 22: ...isit www desatech com ILLUSTRATED PARTS BREAKDOWN MODELS SVYD18PR AND SVYD18NR O F F P I L O T O N H I L O H I L O O F F P I L O T O N 17 17 18 19 24 15 14 16 13 12 12 11 22 23 20 10 9 21 4 8 5 3 2 21...

Страница 23: ...7 15 Pilot Tube 1 10 103781 02 103781 01 Gas Control Valve 1 11 103345 02 103345 02 Lower Bracket 1 12 M11084 38 M11084 38 Screw 8 x 38 7 13 104383 02CK 104383 02CK Painted Base Assy 1 14 098271 10 09...

Страница 24: ...esatech com ILLUSTRATED PARTS BREAKDOWN AMITY SCIVF SERIES PSCIVF SERIES VICTOR HEARTH VH SERIES Indicates Color Suffix Designation ILLUSTRATED PARTS BREAKDOWN SCIVF PSCIVF and VH Series Stove Bodies...

Страница 25: ...44 One Leg Porcelain Enamel Black 4 Total Per Stove 1 6 104176 01 Leg Leveler bolt M8 x 1 25 55mm Long 4 Total Per Stove 1 7 104177 01 Hardware Kit 1 7 1 Door Hinge Step Bolt With Shoulder 1 Per Unit...

Страница 26: ...ote control WALL MOUNT THERMOSTAT SWITCH GWMT1 Not Shown For remote ready models The desired comfort setting can be selected on the wall thermostat and the log heater will automatically cycle from pil...

Страница 27: ...ed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 4...

Страница 28: ...111162 01B 28 For more information visit www desatech com For more information visit www desatech com 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 29: ...___________________________________________________________ _______________________________________________________________________________________________ ____________________________________________...

Страница 30: ...ation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJU...

Отзывы: