6. Replace the rubber plug and tighten the drain knob firmly.
7. Switch on the unit - the full water or compressor operating indicator should not be flashing.
If you wish to operate the unit without the need to empty the water tank, please:
!
Remove the drain knob and rubber plug and
retain for future use.
!
Connect the drain tube supplied to the water
outlet as shown and locate the other end into
a drain.
!
The drain tube may be extended by adding
an extension tube and using a suitable
connector.
11
Please note
1. The drain must be at or below the outlet level.
2. Flashing 'Water Full' indicator will not function in this mode of drainage.
3. If you want to extend the water tube, you can connect it with another tube (OD: 18mm)
Drain knob
Rubber plug
Drain tube
Original drain tube
Extended drain tube
(OD: 18 mm)
Water
stopper
Fig. 22.
Fig. 23.
Fig. 24.