www.desatech.com
15
113681-01A
OPERATING HEATER
Continued
MANUAL LIGHTING
PROCEDURE
1. Remove front panel (see Figure 7, page 9).
2. Follow steps 1 through 5 under
Lighting In-
structions
, page 13.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
5. Replace front panel.
6. Set to desired heating level (see
To Select
Heating Level
, page 14.)
THERMOSTAT MODELS
FOR YOUR SAFETY READ
BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, don’t
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a quali-
fied service technician to inspect the appli-
ance and to replace any part of the control
system and any gas control which has been
under water.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information, col-
umn 1.
2. Make sure equipment shutoff valve is fully
open.
3. Turn thermostat control knob clockwise
Clockwise
to the OFF position (see Figure 21,
page 16).
4. Wait five minutes to clear out any gas. Then
smell for gas, including near the floor. If
you smell gas, STOP! Follow “B” in the
safety information, column 1. If you don’t
smell gas, go to the next step.
5. Turn thermostat control knob counter-
clockwise
C-clockwise
to the PILOT/IGN posi-
tion. Press in thermostat control knob for
5 seconds (see Figure 21, page 16).
Note:
You may be running this heater for
the first time after hooking up to gas sup-
ply. If so, you may need to press in thermo-
stat control knob for 30 seconds or more.
This will allow air to bleed from the gas
system.
• If thermostat control knob does not pop
up when released, contact a qualified ser-
vice person or gas supplier for repairs.
6. Keep thermostat control knob pressed in
while pushing down and releasing the igni-
tor button (see Figure 21, page 16). This will
light pilot. If necessary, continue to press
ignitor button until pilot lights.
If pilot does not light
• turn thermostat control knob clockwise
Clockwise
to the OFF position
• repeat steps 5 and 6
If pilot does not stay lit after several tries
• refer to
Troubleshooting
, page 19
• contact a qualified service person or gas
supplier. Until repairs are made, light pi-
lot with match. To light pilot with match,
see
Manual Lighting Procedure
, page 16.