Interfaces
HydraIP APC-R module
Version: 1.2.0
Datum: 23.11.2017
Seite: 13
3
Interfaces
14pin-connector (1)
Pin no.
Name
Description
I/O characteristics
1
DID_OUT (4)
Coding Pin 4
Output
2
DID_IN(4)
Coding Pin 4
Input
3
DID_OUT(3)
Coding Pin 3
Output
4
DID_IN(3)
Coding Pin 3
Input
5
DID_OUT(2)
Coding Pin 2
Output
6
DID_IN(2)
Coding Pin 2
Input
7
DID_OUT(1)
Coding Pin 1
Output
8
DID_IN(1)
Coding Pin 1
Input
9
DID_OUT(0)
Coding Pin 0
Output
10
DID_IN(0)
Coding Pin 0
Input
11
DOOR-
Negative terminal of door contact Input
12
DOOR+
Positive terminal of door contact
Input
13
Power Supply
Negative terminal (GND)
Input
14
Power Supply
Positive terminal (U IN+)
Input
Do not connect the door contacts (Pin no. 11, 12) of the Counting modules. The door
contacts need to be connected with the recorder.
M12 Ethernet connector D-coded (2)
Connect the counting module with the recorder or switch. Use D-coded plugs only and min. CAT5 cables for
the connection.