31
5-6 Compressor lube oil
Use lube oil exclusively for this series of rotary compressors.
(1) Recommended compressor lube oil and its standard replacement interval
Compressor lube oil : Denyo genuine compressor oil
Corena Oil RS32 (XHVI) Shell
Replacement interval : Every 1000 hours for normal operation
(2) Precautions on oil replacement
Never mix lube oils of different brands or fresh lube oil with in the tank. Such mixing
occasionally produces insoluble glue, lacquer, or shellacs, which may cause the oil filter
to become clogged and break down or cause abnormal wear of the rotor or bearings,
resulting in serious damage. Periodically check the lube for degradation, discoloration,
excessive viscosity, and impurities. When the machine is operated under the following
conditions, the lube oil changing intervals may have to be shortened to about 100 hours.
1) Operation in poorly ventilated locations where the ambient temperature rises excessively.
2) Operation for long duration of time, especially in a tunnel or high humidity.
3) Operation in dusty or sandy locations
Be sure to change the initial lube oil after 500 hours of operation. Your compressor is
provided with Corena Oil RS32 (XHVI) Shell at the factory prior to shipment. If you
replace it with an lube oil of a different brand, be sure to fully extract the old oil
before feeding the fresh one.
(3) Quantity of replacement oil
DIS-390ES/ES-C/ES-D
50L
Value in parentheses is filter capacity.
Содержание DIS-390ES
Страница 58: ...55 10 2 Outline drawing DIS 390ES...
Страница 59: ...56 DIS 390ES trailer type...
Страница 60: ...57 DIS 390ES C...
Страница 61: ...58 DIS 390ES C trailer type...
Страница 62: ...59 DIS 390ES D...
Страница 63: ...60 DIS 390ES D trailer type...
Страница 64: ...61 10 3 Combined Piping Diagram DIS 390ES...
Страница 65: ...62 DIS 390ES C...
Страница 66: ...63 DIS 390ES D...
Страница 67: ...64 10 4 Engine wiring diagram...