Fault finding 

When using a highly technical device do not assume that 

every irregularity is defect. Always consult the table first, 

in  order  to  assess  whether  you  are  able  to  solve  the 

problem yourself. If this does not prove possible, please 

contact our Customer Service by telephone. 

 

Problem   

Possible causes 

Solution / Tip 

The  secondary  air 

valve is open. 

Close 

the 

secondary 

air 

valve. 

The vacuum hose is 

blocked. 

Check  all  of  the 

adapter 

parts, 

valves, 

vacuum 

hose tube etc and 

remove 

the 

blockage. 

Suction  power 

is weak 

 

 

 

The  filters  are  not 

fitted  correctly  or 

they are soiled. 

Check the filters 

and replace them 

with new filters 

where necessary. 

 

The 

device 

does 

not 

switch on 

The  plug  is  not 

correctly 

connected  to  the 

wall socket. 

Check 

whether 

the  wall  socket 

fuse  is  intact.  It 

could  be  that  the 

wall socket itself is 

defective. 

 

 

Safety Instructions

 

 

 

Keep the packing film away from children.(Danger of 

suffocation) 

 

Keep the appliance away from children. 

 

Only use the appliance for the purpose intended! 

 

NEVER  leave  the  device  unattended  when  in 

operation. 

 

This  appliance  operates  using  dangerous  voltage 

levels. Never switch it on if the power supply cable is 

damaged,  or  if  any  other  damage  is  visible  on  the 

appliance. Never open the housing but instead contact 

to  carry  out  repairs.  Use  our  hotline  for  further 

information. 

 

Do  not  use  the  device  to  remove  any  burning  or 

smoking  objects,  such  as  cigarettes, matches  or  hot 

ashes,  any  sharp  objects  such  as  broken  glass,  or 

water  or  any  other  fluids.  Any  of  the  above  could 

damage  the  appliance  and  may  cause  injury  to  the 

operator. Glowing ashes, burning cigarettes etc. may 

set the filter alight, fluids may cause a short circuit and 

sharp objects will damage the filter. 

 

Never expose the appliance to the elements (rain etc.) 

 

Always  unplug  the  appliance  from  the  main  power 

supply before cleaning or servicing (e.g. changing the 

filter) 

 

When  unplug  the  power  cable  from  the  wall  socket, 

please do not pull on the cable. Instead apply gentle 

force to the plug housing.                                       

 

Children are often unable to understand the dangers   

of  using  electrical  equipment  or  may  underestimate   

Содержание CVC-1800

Страница 1: ...Instruction Manual CVC 1800 ...

Страница 2: ...ght Denver Electronics www denver electronics com Do not dispose of this product in the usual household garbage at the end of its lifecycle hand it over at a collection point for the recycling of electrical and electronic appliances The symbol on the product the instructions for use or the packing will inform about the methods for disposal The materials are recyclable as mentioned in this marking ...

Страница 3: ...ly use the appliance for the purpose intended NEVER leave the device unattended when in operation This appliance operates using dangerous voltage levels Never switch it on if the power supply cable is damaged or if any other damage is visible on the appliance Never open the housing but instead contact to carry out repairs Use our hotline for further information Do not use the device to remove any ...

Страница 4: ...r Exhaust filter Remove the plug from the wall socket Never pull on the cable always apply light pressure to the plug housing Remove the exhaust air filter cover by pressing the interlock release button Take out the exhaust air filter and rinse it well under cold clean water before leaving to dry Never clean the exhaust air filter using soap or any other cleaning fluid This would destroy the filte...

Страница 5: ...and body Do not use the appliance without the correct dust receiver tank in place Always unplug the appliance before fitting or removing any accessory parts Read through the assembly instructions carefully before assembling the appliance The assembly sequence must be followed precisely In the interest of your own safety please check the appliance carefully for damage before use In case any faults ...

Страница 6: ...cleaning system from their anchored position using the carry handle located on the dust receiver tank Now simply carry the dust receiver tank to the dustbin Hold the dust receiver tank over your dustbin and push the interlock device back This action will open the bottom of the dust receiver tank which will release its contents into the bin Note if the dust receiver tank is very full it is recommen...

Страница 7: ...eiver tank The dust receiver tank is transparent which means that you are always able to see how full it is You should always empty the dust receiver tank by the time its contents reach the MAX mark Always unplug the appliance before emptying the dust receiver tank Exhaust air subject to multi filter process Electrical regulation of the suction capacity Technical data Main connection 230V 50Hz Cap...

Страница 8: ...been lowered are perfect for cleaning tiles parquet flooring and PVC Secondary air valve The secondary air valve which is located on the device handle allows you to control the suction power of the DENVER CVC 1800 cyclone vacuum cleaner more finely It is recommended that the secondary air valve be opened when cleaning curtains etc in order to avoid them being drawn in to the device To open push fo...

Страница 9: ... ideal when vacuuming sensitive materials such as curtains MIN MAX The middle level is suitable for upholstered furniture carpets and mattresses MAX This level should only be used for robust flooring such as wood and tiles T Brush nozzle The brush nozzle is the best fitting for cleaning sensitive surface such as picture frames or books Crevice nozzle The crevice nozzle is well suited to the vacuum...

Страница 10: ...ngth required Once you have selected the optimum length let the slide return to its original position and ensure that it snaps shut Now attach the floor brush to the telescopic tube as shown in the diagram Attach the crevice nozzle and brush nozzle using the same method Operations Vacuuming Before use ensure that you have released a sufficient length of cable then plug the device into the wall soc...

Отзывы: