9
9
DN-C635
6. Test Mode (Heat Run mode)
z
Switch on the power while pushing the FOLDER button and TIME button at the same time.
"
000TroHR0000
" is displayed. And the tray is opened.
(1)Hold the disc by the edges and place it on the disc tray.
(2)Starting with the OPEN/CLOSE button, it repeats open/close of the tray and playback.
***TrxHRXXXX
***: Track No.
x : o, c, s, t, r, and p
XXXX: Cycle quantity
All tracks are played back if the track count is less than 20.
Only the first and last tracks are played back if the tracks are more than 21.
When any errors, it stops and indicates error code (Refer to the Error Code Table).
(3)To stop the Test mode, please turn off the POWER switch.
7. Error Code Table
Error Code
CONTENTS
Error 01
Unable to close the loader tray in the regulation time.
Error 02
Unable to open the loader tray in the regulation time.
Error 03
Inner circle switch ON error even if the time is over.
Error 04
Inner circle switch OFF error even if the time is over.
Error 05
The focus offset adjustment result is outside the regulation range.
Error 06
Unable to adjust the focus offset in the regulation time.
Error 07
The tracking offset adjustment result is outside the regulation range.
Error 08
Unable to adjust the tracking offset in the regulation time.
Error 09
The FE peak is outside the regulation range.
Error 0A
The FE peak is outside the regulation range.
Error 0B
Unable to adjust the focus rough gain in the regulation time.
Error 0C
The focus rough gain is outside the regulation range.
Error 0D
Unable to actuate focus in the regulation time.
Error 0E
Unable to actuate tracking in the regulation time.
Error 0F
Unable to adjust the tracking rough gain in the regulation time.
Error 10
The tracking rough gain is outside the regulation range.
Error 11
Unable to adjust the tracking balance in the regulation time.
Error 12
The tracking balance adjustment result is outside the regulation range.
Error 13
Focus servo down during automatic adjustment.
Error 14
Focus servo down during automatic adjustment.
Error 15
Unable to adjust the focus balance in the regulation time.
Error 16
The focus balance adjustment result is outside the regulation range.
Error 17
Track servo down during automatic adjustment.
Error 18
Unable to adjust the focus fine gain in the regulation time.
Error 19
The focus fine gain is outside the regulation range.
Error 1A
Unable to adjust the tracking fine gain in the regulation time.
Error 1B
The tracking fine gain is outside the regulation range.
Error 1C
Unable to adjust automatically in the regulation time.
Error 1D
Unable to read the subcode Q in the regulation time.
Error 1E
Unable to read the TOC in the regulation time.
Error 1F
Focus servo down during search (over the regulation time).
Error 20
Track servo down during search (over the regulation time).
Error 2116
Servo error during search.
Error 2103
Search error (over the regulation time).
Error 22
Discontinuity occurred, during write to the DRAM.
Error 23
The error which cannot be corrected to the read data.
Error 24
Unable to do the level detect.
Error 25
Unable to join data in the regulation time.
Error 26
The error rate when recording on the memory is over the regulation value.
Error 27
The subcode jump more than regulation.