AVR-S700W (1 of 3)
1
Procedure to enter the “Protection History Display Mode”.
1. Hold down buttons “
TUNER PRESET CH-”, “TUNE-” and “TUNER PRESET CH+”
at the same time and press the power button to turn on the power.
2. Select "
PROTECTION
" using the “
TUNER PRESET CH+/-
“ button, and press the “
STATUS
" button.
3. Press the "
STATUS
" button again and the unit will display the Protection History condition.
TUNER PRESET CH+
TUNER PRESET CH-
TUNE-
POWER
PROTECTION HISTORY DISPLAY MODE
CLEARING THE PROTECTION HISTORY
Protection History Mode records and displays an event in which the THERMAL, CURRENT, ASO or DC protection was activated.