Dennard 2040 Скачать руководство пользователя страница 10

a DM Group company

Dome Mounting

2040  

Installation Manual

Sheet. 

8

Dome Mounting

Once the 2040 dome camera has been configured it

can be fitted into the shell mounted in the ceiling.  For

safety reasons, IT IS ESSENTIAL that the safety bond

is used to secure the dome to the shell.  The safety

bond is fitted inside the shell and has a small metal clip

on the end of the cable.  Offer up the dome camera

and secure the clip to the ring at the top of the clear

plastic case as shown in 

(Fig. 11)

.

Having attached the safety bond insert the dome 

camera into the shell, ensuring that the safety bond

does not become twisted around the case.  Locate the

metal bayonet connector firmly into the top of the shell

and rotate the dome clockwise until the unit latches into

place 

(Fig. 13)

.

To secure the unit in place, tighten the single locking

small screw on the hemisphere flange.  If the screw

cannot be tightened the dome mechanism may not be

properly located in the bayonet connector.  Remove the

unit and repeat the steps above until the dome clicks

into place and the screw can be tightened.

The 2040 dome camera is now ready for use. For 

information on how to program and operate the camera

refer to the 2040 programming manual.

Fig.13 Offering Up

Fig.11 Safety Clip

Содержание 2040

Страница 1: ...2040 Dennard support line 44 0 1420 485713 INSTALLATION MANUAL Doc 74 087 ...

Страница 2: ...a DM Group company ...

Страница 3: ...ation to install the Series 2040 Precision Dome Camera Please refer to the Programming manual for operation and programming features sheet 1 Introduction Index sheet 2 List of contents sheet 3 Tile Mounting sheet 4 Tile Mounting sheet 5 Control Configuration Up the Coax sheet 6 Control Configuration RS485 Serial Connection sheet 7 Control Configuration Twisted Pair sheet 8 Dome Mounting sheet 9 No...

Страница 4: ... safety bond 1 x Cardboard Mounting Template N B A power supply unit may have been ordered and delivered separately In addition to the above components the following paperwork is supplied Type 2040 Installation Manual Type 2040 Programming Manual List of contents Components supplied Hole Template Note The top section of the packaging provides a template for marking out mounting holes DO NOT DISCAR...

Страница 5: ... panel should be used behind the ceiling tile to distribute the weight to the support frame We recommend that the tile should be removed if possible from the ceiling to simplify the marking and cutting out of mount ing holes Using the Mounting template Fig 1 which is provided as part of the packaging within the box mark out the ceiling hole and centre points for the 3 off 9mm holes Cut and drill t...

Страница 6: ... the necessary cables through the hole in the ceiling and connect the 24V ac power coax and optional RS485 cables as shown in table below Reconnect the plug ensuring the correct position see Fig 3 4 Offer up the shell pushing the fixings through the three screw holes Tighten the screws clamping down on the ceiling tile to secure the shell in the ceiling cavity The shell is now ready to accept the ...

Страница 7: ... the controller being used as shown in table below The switches are factory set to 253 Den Panel Table 9 Address chart Table 8 Switch settings 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 A B C D E F Yellow 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 ...

Страница 8: ... PSU Local 230Va c Input 24 Ac Coax Video Coax Video Termination Resistor Out Termination Resistor In Termination Resistor In Termination resistor In RS485 Data link Twisted Pair 20mA current loop 4 x local alarms Video cable To controller 1 to 16 Dome Cameras 1 to 16 Dome Cameras Local 230Va c Input To controller RS 485 Data link Daisy chain connect to controller PSU Local 230Va c Input PSU Coax ...

Страница 9: ...5 Data link Daisy chain connect to controller PSU Local 230Va c Input PSU Coax Video RS485 From the Controller Coax Video Local 230Va c Input PSU Local 230Va c Input Star Card Fig 10 Twisted Pair Twisted Pair Configuration 2040 domes can be operated on 20mA current loop twisted pair cabling by using a DRX100 card and power supply Dennard part num 95066 In this configuration the switches must be se...

Страница 10: ...ert the dome camera into the shell ensuring that the safety bond does not become twisted around the case Locate the metal bayonet connector firmly into the top of the shell and rotate the dome clockwise until the unit latches into place Fig 13 To secure the unit in place tighten the single locking small screw on the hemisphere flange If the screw cannot be tightened the dome mechanism may not be p...

Страница 11: ...a DM Group company Notes 2040 Installation Manual Sheet 9 ...

Страница 12: ...2040 55 Fleet Road Hants GU51 3PN T 44 0 1252 614884 F 44 0 1252 626013 email sales dennard cctv com Doc 74 087 a DM Group company ...