Save Outputs
- when checked, each time a Relay or Analog Output value is
changed, it will be saved in non-volatile memory (EEPROM), so after
reboot/restart it will be restored;
This option should be used with care in dynamic systems because of
restriction in maximum write cycles of the EEPROM (usually 100 000
write/erase cycles).
Monitoring Timeout, sec
- the connection timeout for the Web-browser;
Max. Monitoring Errors
– the number of successive timeouts before the
connection error is reported by the Web-browser;
Save button
- once you have changed the settings as required, click this
button.
7.4. Network settings
The page shown in Fig. 7.7 lets you configure the network settings of
smartDEN
IP-Maxi
module.
Figure 7.7.
Network settings
Enable DHCP
- this option allows DHCP to be enabled or disabled. If DHCP is
set to Enabled, the Network page must be saved and
smartDEN IP-Maxi
must be rebooted before obtaining an IP address;
IP address
- this is the IP address of the
smartDEN IP-Maxi
. It has to be
manually assigned only if DHCP is disabled. With DHCP enabled, this field
displays the currently assigned address;
Gateway
- this specifies the IP address of the gateway router. It is used for
accessing public SNTP servers for automatic time synchronization;
Subnet Mask
- this is the subnet mask for the network on which the
smartDEN IP-Maxi
is installed;
Primary DNS
- primary DNS (Domain Name Service) address;
Secondary DNS
- secondary DNS address;
Save button
- once you have changed the settings as required, click this
button.
You have to reboot the device for these settings to apply.