9. Faults 

 
Warning!

 Before starting work on the cleaning table fixtures, switch off the electrics and unplug from the 

mains! Test the equipment to ensure the power is off!  
 

Fault  

Cause  

Solution 

 

Detergent cold, heating sys-
tem not working  

1. The heater is not connected 

properly or is faulty;  

2. Fuse faulty 
3. Safety temperature limiter has 

been triggered 

1. Check the electrical connections of the 

heater. If necessary replace the heater 

2. Replace fuse (11). 
3. Check the appliance, remove the 

cause for the overheating, press the 
button for the safety temperature lim-
iter (10) 

Wash pump not working 

1. The wash pump is not con-

nected properly or is faulty;  

2. Fuse faulty 

1. Check the electrical connections of the 

wash pump. If necessary replace the 
wash pump 

2. Replace fuse (13).  

Aerator not working 

1. The aerator is not connected or 

is faulty 

2. Fuse faulty 

1. Check the electrical connections of the 

aerator. If necessary replace the aera-
tor 

2. Replace fuse (12). 

Level switch not working 

1. The level switch is not con-

nected properly 

2. The level switch is faulty. Short-

circuit in level switch 

1. Check the electrical connection of the 

level switch.  

2. Replace level switch 

Heating system and wash 
pump not working. Level 
display flashing 

Fill level fallen below minimum 
level 

Refill with detergent 

Level display flashing, al-
though the appliance is filled 
sufficiently 

The ball in the float switch is stuck  Lift the float switch (8.4) briefly 

 
 
Note: 

To check the fuses the technical components (Item 8) can be removed completely from the appliance after 
pulling the hose from the ball valve and loosening the tapping screws.  
If you have a more complex fault please contact our service technician. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Bio.x B200

Страница 1: ...Cleaning Table USERS MANUAL 01 2010 175733_BA_EN_006 ...

Страница 2: ...ct description 4 3 1 Layout 4 3 2 Intended use 5 3 3 How it works 5 4 Initial Operation 5 4 1 Filling with the cleaning fluid 5 4 2 Electrical connection 5 5 Operation 6 6 Maintenance 6 7 Optional Accessories 8 8 Notes regarding disposal 8 9 Faults 9 10 Connection Diagram 10 11 EC Declaration of Conformity 11 ...

Страница 3: ...ans For safety reasons the equipment must be only operated if a Residual Current protective Device RCD with a release current of 30 mA is connected upstream This must be checked by a qualified electrician In accordance with the German BGV A3 electrical equipment has to be examined in regular inter vals Detergents which contain highly flammable substances must not be used Use only detergents ap pro...

Страница 4: ...nents set 175340 1 Sump 8 1 heater 186596 2 Stand top 8 2 Pump 134979 3 Stand top seal 175033 8 3 Aerator 135310 4 600 µm filter screen 135256 8 4 Level switch 174951 5 Coarse filter 135255 6 Cleaning unit set 175370 9 Filter set optional 172237 6 1 Ball valve 135279 9 1 Filter insert central support bracket and nylon filter 150043 6 2 Wash brush 135277 9 2 O ring 150609 A B 172236 172292 176074 ...

Страница 5: ...f necessary level out any uneven surfaces with suitable shimming material 4 1 Filling with the cleaning fluid The unit can be opened at the side for servicing or to fill the tank with fresh detergent To do so lift up the right hand side of the unit top and prop it up using the bar you can find inside Maintenance position of stand top aperture angle approx 50 The cleaning fluid bio x is available a...

Страница 6: ...rvicing or to fill the tank with fresh detergent see point 4 1 Fill level Check the fill level regularly so you can refill to make up for any losses through evaporation and removal The mark on the back wall of the container shows the maximum fill length If the minimum fill level approx 23 cm below the maximum level is reached the pump and the heating system switch off automatically for safety reas...

Страница 7: ...ng performance when checking the fill level there are notable sediment deposits on the floor of the tank Use the draining device 7 to drain the dirty fluid Then the tank has to be freed from any sediment residue Please follow the same process when inserting the new fluid as for the initial operation Refill items Accessories Description Item number Bio Power cleaning fluid 20 litre canister 175715 ...

Страница 8: ...ush To remove heavily crusted dirt from insensitive parts 173926 Wet vacuum cleaner Type SV 6 16 To completely empty the tank also suitable for sludge 123224 Flexible hose The flexible hose with flat nozzle guarantees simple rinsing of the parts 135289 Lid 174288 8 Notes regarding disposal Detergent The relevant waste code number for a contaminated substance depends on the type of dirt removed and...

Страница 9: ...p If necessary replace the wash pump 2 Replace fuse 13 Aerator not working 1 The aerator is not connected or is faulty 2 Fuse faulty 1 Check the electrical connections of the aerator If necessary replace the aera tor 2 Replace fuse 12 Level switch not working 1 The level switch is not con nected properly 2 The level switch is faulty Short circuit in level switch 1 Check the electrical connection o...

Страница 10: ...0 of 12 01 2010 10 Connection Diagram 5x20mm 5A T 5x20mm 0 1A M 5x20mm 1A M Power line 230 VAC heater Air pump pump Flopat switch Indicator light Pump switch Indicator light Pump switch Float switch 172236 172292 176074 ...

Страница 11: ... 42 EC 2004 108 EC Harmonised standards applied EN 349 EN 12100 1 2 EN 60204 1 172236 172292 176074 EN 12981 1 2 Person responsible for documentation DENIOS AG AG 04 01 2010 Mr Dr Ing R Adenstedt Theodor Breucker Head of engineering Board of governors Address see below DENIOS AG Dehmer Straße 58 66 32549 Bad Oeynhausen Tel 49 0 5731 7 53 0 Fax 49 0 5731 7 53 197 E Mail info denios com You ll find ...

Страница 12: ...bio x B200 Page 12 of 12 01 2010 172236 172292 176074 ...

Отзывы: