background image

 

I-963 

 

Page 3 of 6 

Rev. E-37870   5/17/12 

Installation   

 
Mounting Dispenser Assembly  

1.

 

Remove the ball valve screw and knob then slide the cover off of the valve 
assembly. 

2.

 

Position the dispenser on the wall and mark the four mounting screw 
locations.  

3.

 

Install the supplied anchors in the wall and install the screws half way into 
the anchors. 

4.

 

Slide the dispenser over the screw heads and tighten down the screws.    

5.

 

Install the desired metering tip in the elbow as shown.  

6.

 

Cut the chemical supply tube to length by removing excess tubing.  Install 
the supplied ceramic weight onto the tube then install the tube onto the 
elbow barb.  Place the tube end with the ceramic weight and foot valve into 
the proper chemical container.  Note: Chemical container can be no greater 
than 6’ (1.83 meters) below the dispenser. 

7.

 

Cut outlet tubing to desired length and install to proportioner barb.  Properly 
place tubing in sink where chemical is desired.  

8.

 

Replace the cover, ball valve knob, and tighten the screw.                                  
 

Water Supply  
(Inlet pressure must be between 20 psi (1.38 bar) and 125 psi (8.62 bar)).    

1.

 

Attach a garden hose to the water inlet on the unit. 

 

Table 1: “Air Gap” & “Action Gap” Induction Flow Rates w/Standard 1/4" Barb and Tubing 

 

Metering 

Tip 

Color 

163 BAG (4 GPM Flow Rate Air Gap Proportioner) 

Injection Rates For Viscosities Shown 

(4 GPM Flow Rate Action Gap Proportioner) 

Injection Rates For Viscosities Shown 

1 cps  

75 cps 

200 cps 

1 cps 

75 cps 

200 cps 

Oz/Gal 

Ratio 

Oz/Gal 

Ratio 

Oz/Gal 

Ratio 

Oz/Gal 

Ratio 

Oz/Gal 

Ratio 

Oz/Gal 

Ratio 

Tan 

0.30 

427-1 

0.20 

640-1 

0.15 

853-1 

0.33 

387-1 

0.26 

500-1 

0.12 

1090-1 

Orange 

0.40 

320-1 

0.30 

427-1 

0.25 

512-1 

0.42 

307-1 

0.32 

430-1 

0.17 

735-1 

Turquoise 

0.60 

213-1 

0.40 

320-1 

0.30 

427-1 

0.51 

251-1 

0.34 

382-1 

0.19 

676-1 

Pink 

0.80 

160-1 

0.50 

256-1 

0.40 

320-1 

0.78 

165-1 

0.56 

230-1 

0.3 

422-1 

Light Blue* 

1.00 

128-1 

0.70 

183-1 

0.45 

284-1 

0.87 

147-1 

0.67 

192-1 

0.33 

391-1 

Brown 

1.20 

107-1 

0.80 

160-1 

0.50 

256-1 

0.99 

129-1 

0.74 

174-1 

0.37 

345-1 

Red 

1.50 

85-1 

0.90 

142-1 

0.60 

213-1 

1.37 

93-1 

0.91 

141-1 

0.44 

289-1 

White 

1.85 

69-1 

1.10 

116-1 

0.70 

183-1 

1.52 

84-1 

1.04 

123-1 

0.48 

264-1 

Green 

2.00 

64-1 

1.25 

102-1 

0.80 

160-1 

1.72 

74-1 

1.22 

105-1 

0.52 

244-1 

Blue 

2.50 

51-1 

1.50 

85-1 

0.82 

156-1 

2.13 

60-1 

1.27 

101-1 

0.54 

239-1 

Yellow 

4.00 

32-1 

1.85 

69-1 

0.90 

142-1 

3.05 

42-1 

1.71 

75-1 

0.56 

229-1 

Black 

5.50 

23-1 

2.00 

64-1 

0.94 

136-1 

4.50 

28-1 

1.96 

65-1 

0.57 

224-1 

Purple 

8.80 

15-1 

2.40 

53-1 

0.96 

133-1 

7.75 

17-1 

2.4 

53-1 

0.59 

217-1 

Gray 

11.65 

11-1 

2.50 

51-1 

1.00 

128-1 

9.86 

13-1 

2.54 

50-1 

0.63 

204-1 

No Tip 

16.20 

8-1 

3.00 

43-1 

1.20 

107-1 

19.63 

7-1 

3.16 

40-1 

0.67 

190-1 

*Metering tip color was formerly clear. 
Notes: All induction flow rates are based on a water pressure of 40 psi. 
(1 cps (centipoises)-viscosity of water, 75 cps-viscosity of light weight detergents, 200 cps-viscosity of most dishwasher detergents)   
Leaner dilutions can be achieved by ordering DEMA ultra lean metering tip kit 100-15KU. 
Ratios as low as 100 parts-per-million can be achieved with the use of a DEMA capillary metering tip.  Contact DEMA customer service 
for more information. 
If you are having difficulty achieving the ratio you require, call DEMA and ask for the technical service department. 

Отзывы: