Connection of the injector to a 2" line 

Note the direction of the water flow. Assemble the injector with the arrow stamped on the body of 

the  injector  pointing  in  the  direction  of  the  water  flow.  Connect  the  injector  using  the  plastic 

couplings. 

For a drinking water line all injectors must have a backflow prevention valve installed in front of the 

injector on the main water line, in accordance with local regulations.

 

 

Connection of the injector to a 63mm plastic pipeline 

Note the direction of the water flow. Assemble the injector with the arrow stamped on the body of 

the injector pointing in the direction of the water flow. 

Cut and round the edges of the inlet and outlet pipes. The distance between the end of the inlet 

pipe and the end of the outlet pipe should be 22cm. 

Remove the 63mm nut and the white ring from the injector, and fit them on to the pipe a short 

distance from the end.  

Check that inside the injector there is the 

seal  for  63mm  accessories  and  that  the 

bushing for the 63mm seal closes it from 

the outside. 

Insert  the  pipe  into  the  inlet  and  outlet 

opening  and  push  hard  so  that  the  pipe 

penetrates,  and  passes  the  seal,  and  is 

stopped at the end of the route. To ease 

Insertion  apply  a  little  silicon  grease  to 

the end of the pipe.  

Push  the  white  ring  until  it  contacts  the 

threaded  part,  and  tighten  the  nut. 

Repeat  the  process  in  order  to  connect 

the pump to the pipe on the other side.

 

* Optional Special grip ring for P.V.C pipes 

 

Installation of the injector on a direct line 

It is recommended to fit a main valve at the beginning of the line (1), and a water filter of 200 

mesh (2). A backflow prevention valve (3) must be fitted to a drinking water line, in accordance 

with local regulations, in order to prevent entry of chemicals into the drinking water. Then place 

the following pressure reducer (4), 

 to  protect  the  injector  from  excess 

pressure;  a  valve  before  the  inlet  to  the 

injector (5);  a  valve after  the  outlet (6); 

an  anti  vacuum  valve  (7)  to  prevent  a 

siphon  effect  when  the  injector  is  not 

working; and operating valves (8) for the 

branch lines. 

It  is  advisable  to  add  a  bypass  pipe  (9) 

that  will  permit  diverting  the  water  flow 

through the bypass pipe if there is a need 

for irrigation without any additives, or for 

dismantling the injector. 

2

1

3

4

5

6

8

7

9

1

Содержание MixRite TF-25

Страница 1: ...MixRite TF 25 ...

Страница 2: ...ter passing through the MixRite TF 25 is between 2 and 25 m3 hour 530 6600 gal hour The water pressure is between 1 and 8 bar 14 120 PSI Head loss for MixRite TF 25 Minimum flow 0 1 Bar Maximum flow 1 5 Bar The water air temperature are not less than 4ºC 40ºF and not more than 40ºC 104ºF The flow rate of the additive can be adjusted relative to the flow rate of the water in the range of 0 1 to 1 f...

Страница 3: ...and a filter A stand comprising 4 legs 2 arched braces 4 bolts with 8 mm nuts and 4 bolts with 6mm nuts Spanner for TF cover nut User s manual To assemble the stand Insert the narrow part of the leg into the opening in the tube in the arched brace Make sure that the holes in the leg are opposite the holes in the arched brace Insert the 6mm bolt and tighten the nut Repeat with the other legs Attach...

Страница 4: ...tion tube Insert the flat seal into the nut of the coupling on the end of the tube 1 Thread and tighten the nut to the inlet valve on the underside of the injector Make sure that the nut is threaded and tightened properly 2 3 ...

Страница 5: ...t the pipe into the inlet and outlet opening and push hard so that the pipe penetrates and passes the seal and is stopped at the end of the route To ease Insertion apply a little silicon grease to the end of the pipe Push the white ring until it contacts the threaded part and tighten the nut Repeat the process in order to connect the pump to the pipe on the other side Optional Special grip ring fo...

Страница 6: ...ng of the line 1 water filter of 200 mesh 2 backflow prevention valve 3 must be fitted to a drinking water line according to local regulations in order to prevent entry of chemicals to the drinking water A pressure reducer 4 a T connection for diversion from the main line to the bypass a valve 5 on the bypass before the inlet to the proportioning dosing injector a valve 6 after the outlet from the...

Страница 7: ... a regulation valve 6 the injector a non return valve 7 after the outlet from the injector and a return connection to the main line 8 anti vacuum valve 9 Both sides of the instillation must be identical Connection to the additive tank The suction tube should be connected to the additive tank preferably about 5cm above the bottom diagram A The liquid additive must pass through a chemical resistant ...

Страница 8: ...site direction to the water flow direction Fit the injector with the arrows in the direction of flow s e v l a v e h t n e p O d e s o l c e r a s e v l a v t e l t u o d n a t e l n i e h T r e t l i f e h t n a e l C d e k c o l b s i r e t l i f t e l n i e h T The injector does not work e v l a v n i a m e h t n e p O e r u s s e r p e t a i r p o r p p a e h t t a w o l f r e t a w o n s i e ...

Отзывы: