DEMA 830 Laundry Master
TM
Installation Instructions
I-656
Pg. 6 of 9
Rev D28632
Programming
It is helpful to know the amount of chemical product to be dispensed before programming the Laundry
Master. To assure that a specific application is satisfied, it is recommended that the output rate of the
specific chemical product be measured by use of a graduated cylinder.
The programming function will set the delay time and the amount of time that the pump will run when a
trigger signal is received from the laundry machine.
1.
Note that the front face of the Laundry Master has a button labeled “
PROG/PRIME
” and a round
window labeled “
CHARGE
”.
2.
Press and hold the “PROG/PRIME” button to activate the programming function. The “
CHARGE
”
light will illuminate. Continue holding the button for about 8 seconds until charge light goes out,
turns on, and then begins flashing. Release the button.
3.
The “
CHARGE
” light will continue to flash. The delay time is now being recorded. This time can be
set between 0 and 4 minutes 15 seconds.
4.
Press the “PROG/PRIME” to stop the delay time. The pump will begin to run. The pump run time is
now being recorded. The minimum amount of time is 10 seconds and the maximum amount of time is
4 minutes and 15 seconds.
5.
Allow Laundry Master to pump for the desired amount of time. Push the “
PROG/PRIME
” button to set
that amount of time and exit the programming function.
Lockout Time
The lockout time is set via four DIP switches found on the control board inside the Laundry Master
enclosure. See Figure 3 for DIP switch location.
Lockout Time
Switch 1
Switch 2
Switch 3
Switch 4
0 Minutes
OFF
OFF
OFF
OFF
5 Minutes
ON
OFF
OFF
OFF
10 Minutes
OFF
ON
OFF
OFF
15 Minutes
ON
ON
OFF
OFF
20 Minutes
OFF
OFF
ON
OFF
25 Minutes
ON
OFF
ON
OFF
30 Minutes
OFF
ON
ON
OFF
35 Minutes
ON
ON
ON
OFF
40 Minutes
OFF
OFF
OFF
ON
45 Minutes
ON
OFF
OFF
ON
50 Minutes
OFF
ON
OFF
ON
55 Minutes
ON
ON
OFF
ON
60 Minutes
OFF
OFF
ON
ON
65 Minutes
ON
OFF
ON
ON
70 Minutes
OFF
ON
ON
ON
75 Minutes
ON
ON
ON
ON
Testing the Program
Pressing and holding the “
PROG/PRIME
” button activates the test function. The “
CHARGE
” light will
illuminate. Continue holding the button for about five seconds until charge light goes out. Release the
button. Then press and release “
PROG/PRIME
” button within ½ second. The “
CHARGE
” light will
illuminate indicating the program is running. It will stay illuminated for the delay time. The light will be