Programming

It is helpful to know the amount of chemical product to be dispensed before programming the Laundry
Master. To assure that a specific application is satisfied, it is recommended that the output rate of the
specific chemical product be measured by use of a graduated cylinder.

The programming function will set the delay time and the amount of time that the pump will run when a
trigger signal is received from the laundry machine.

1.

 

Note that the front face of the Laundry Master has a button labeled “

PROG/PRIME

” and a round

window labeled “

CHARGE

”.

2.

 

Press and hold the “PROG/PRIME” button to activate the programming function.  The “

CHARGE

light will illuminate.  Continue holding the button for about 8 seconds until charge light goes out,
turns on, and then begins flashing.  Release the button.

3.

 

The “

CHARGE

” light will continue to flash.  The delay time is now being recorded. This time can be

set between 0 and 4 minutes 15 seconds.

4.

 

Press the “PROG/PRIME” to stop the delay time.  The pump will begin to run.  The pump run time is
now being recorded. The minimum amount of time is 10 seconds and the maximum amount of time is
4 minutes and 15 seconds.

5.

 

Allow Laundry Master to pump for the desired amount of time. Push the “

PROG/PRIME

” button to set

that amount of time and exit the programming function.

Lockout Time

The lockout time is set via four DIP switches found on the control board inside the Laundry Master
enclosure. See Figure 3 for DIP switch location.

Lockout Time

Switch 1

Switch 2

Switch 3

Switch 4

0 Minutes

OFF

OFF

OFF

OFF

5 Minutes

ON

OFF

OFF

OFF

10 Minutes

OFF

ON

OFF

OFF

15 Minutes

ON

ON

OFF

OFF

20 Minutes

OFF

OFF

ON

OFF

25 Minutes

ON

OFF

ON

OFF

30 Minutes

OFF

ON

ON

OFF

35 Minutes

ON

ON

ON

OFF

40 Minutes

OFF

OFF

OFF

ON

45 Minutes

ON

OFF

OFF

ON

50 Minutes

OFF

ON

OFF

ON

55 Minutes

ON

ON

OFF

ON

60 Minutes

OFF

OFF

ON

ON

65 Minutes

ON

OFF

ON

ON

70 Minutes

OFF

ON

ON

ON

75 Minutes

ON

ON

ON

ON

Testing the Program

Pressing and holding the “

PROG/PRIME

” button activates the test function.  The “

CHARGE

” light will

illuminate.  Continue holding the button for about five seconds until charge light goes out. Release the
button.  Then press and release “

PROG/PRIME

” button within ½ second.  The “

CHARGE

” light will

illuminate indicating the program is running.  It will stay illuminated for the delay time.  The light will be

Содержание Laundry Master 830

Страница 1: ...DEMA 830 Laundry MasterTM Installation Instructions I 656 Pg 1 of 9 Rev D28632...

Страница 2: ...aundry Master on a wall by use of the supplied hanger kit and screw and anchor kit Note The supplied screw and wall anchors may not be suitable The wall construction at point of installation should be...

Страница 3: ...aundry Master trigger connection points Trigger lines should be properly secured by use of proper electrical fitting through access hole in Laundry Master enclosure The signal line must be properly se...

Страница 4: ...machine Cut off all excess tubing and keep tubing away from hot surfaces and sharp edges to prevent damage or leakage Dry Detergent valve Use compression fittings to connect LDPE tubing between the o...

Страница 5: ...DEMA 830 Laundry MasterTM Installation Instructions I 656 Pg 5 of 9 Rev D28632 Figure 1 Figure 2 JUMPER SEE FIGURE 1 AND 2 DIP SWITCHES HOOK UP TERMINALS Figure 3...

Страница 6: ...n time is now being recorded The minimum amount of time is 10 seconds and the maximum amount of time is 4 minutes and 15 seconds 5 Allow Laundry Master to pump for the desired amount of time Push the...

Страница 7: ...for the length of time that the PROG PRIME button is pressed This function is used to prime an empty suction and discharge tube Pressing and holding the PROG PRIME button activates the prime function...

Страница 8: ...rew used for mounting circuit board 81 13 6 Modular 6 Pole Terminal Block used on circuit board 80 59 60 60 RPM Gear Motor 80 59 105 105 RPM Gear Motor 25 65CE 11 Squeeze Tube for C2 pump 25 89CE 14 S...

Страница 9: ...k Up Tube used with LDPE tubing 80 66 2 18 PVC Pick Up Tube used with LDPE tubing Return Policy No merchandise may be returned for credit without DEMA Engineering Company s written permission Return M...

Отзывы: