background image

I-1305   Rev. N-47130 

               9.23.2021 

    PAGE 9 OF 11 

Replacement Parts Valve Body

 

 

 

 

 

 

VALVE REPLACEMENT PARTS 

Item No. 

DEMA Part No. 

QTY 

DESCRIPTION 

40.854.1 

RETAINING CLIP PILOT ACTIVATED VALVE

 

41.058.1 

DIAPHRAGM CAP

 

619.21 

O-RING SEAL EPDM (

15/16” X 1/16”

)

 

98.26.1 

1-1/16" DIAPHRAGM

 

40.824.1 

VALVE BODY

 

40.849.1 

BUTTON, PILOT ACTIVATED VALVE

 

640.106 

O-RING SEAL (3/16"ID X 3/8"OD X 3/32"NOM.)

 

98.39.2 

RETURN SPRING

 

63.78 

O-RING-SEAL EPT (7/16"I.D. X 9/16"O.D. X 1/16 
NOM.)

 

10 

40.851.1 

BOTTOM CAP

 

11 

40.925.1 

FUSION INLET ADAPTER W/GHT 

11 

40.925.2 

FUSION INLET ADAPTER W/BSPP 

11 

40.925.3 

FUSION INLET ADAPTER W/GHT, PLASTIC 

11 

40.925.4 

FUSION INLET ADAPTER W/BSPP, PLASTIC 

12 

40.927.1 

3/8

 ELBOW COMPRESSION INLET FITTING 

13 

40.927.2 

3/8

 STRAIGHT COMPRESSION INLET FITTING 

14 

40.927.3 

3/8

 JOHN GUEST PUSH-ON INLET FITTING 

15 

40.927.4 

3/8

 ELBOW JOHN GUEST PUSH-ON INLET 

FITTING 

16 

40.927.5 

3/8

 BARB INLET FITTING 

Содержание Fusion One

Страница 1: ...sion One is engineered with 1055 approved back flow protect using DEMA s Air Gap or Action Gap proportioning system Warnings All installations must conform to local plumbing codes and use approved bac...

Страница 2: ...over by pressing the plastic tabs on the side of the unit and swing the bottom away from the mounting bracket 3 Determine if the water supply connection should be on the right of left hand side of the...

Страница 3: ...ne cover by positioning the top of the cover near the top of dispenser back plate and push the cover back over the valve assembly until the tab latches on side of the unit 8 Connect the water line to...

Страница 4: ...GE 4 OF 11 Installation and Servicing Continued 9 Removal of Button Tab to engage Locking Activation feature for 4GPM Proportioners Step 1 Remove Fusion One cover see 2 above Step 2 Break off tab with...

Страница 5: ...Black 17 36 119 45 7 37 4 53 34 19 28 25 Purple 31 36 196 81 4 08 7 67 56 53 16 69 Gray 34 95 214 51 3 66 8 77 64 15 14 59 No Tip 35 95 219 31 3 56 10 54 76 05 12 15 Table 1 Fusion Metering Tips 100...

Страница 6: ...59 9 92 4 86 36 59 26 34 Purple 26 69 172 54 4 80 11 31 81 19 11 32 Gray 30 36 191 72 4 22 13 76 97 10 9 30 No Tip 45 48 262 17 2 81 24 77 162 15 5 17 Table 3 Fusion Metering Tips 100 15K Provided Me...

Страница 7: ...units can be connected together using the Fusion Valve Connector 41 186 1 It would replace the Plug Adapter 40 926 1 on one of the units and the Inlet Adapter Assembly 40 925 1 40 925 2 of the other u...

Страница 8: ...RTIONER ASSEMBLY 4GPM 15 16 30 1 ACTION GAP 16 65 10 2 1 STANDARD COUPLING GARDEN HOSE THREAD 16 98 55 1 1 EURO COUPLING BRITISH HOSE THREAD 17 40 852 1 1 WATER INLET FITTING PILOT ACTIVITED VALVE 18...

Страница 9: ...L 3 16 ID X 3 8 OD X 3 32 NOM 8 98 39 2 1 RETURN SPRING 9 63 78 1 O RING SEAL EPT 7 16 I D X 9 16 O D X 1 16 NOM 10 40 851 1 1 BOTTOM CAP 11 40 925 1 1 FUSION INLET ADAPTER W GHT 11 40 925 2 1 FUSION...

Страница 10: ...I 1305 Rev N 47130 9 23 2021 PAGE 10 OF 11 Product Dimensions FUSION ONE FRONT VIEW FUSION ONE LEFT END VIEW FUSION ONE RIGHT END VIEW...

Страница 11: ...ply to any products that have a normal life shorter than one year or failure and damage caused by chemicals corrosion physical abuse or misapplication Rubber and synthetic rubber parts such as o rings...

Страница 12: ...I 1305 Rev N 47130 9 23 2021 PAGE 12 OF 11 3 FUSION MOUNTING TEMPLATE...