DEMA ATLAS 844P Series Скачать руководство пользователя страница 9

DEMA ATLAS 844P

  SERIES 

LAUNDRY CONTROL

 

I-907 

 

Page 9 of 17 

Rev. C-33371 

 

Tubing Connections 

ALWAYS WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING WITH 
CHEMICALS PRODUCTS. 

An optional installation kit may be ordered with the 844P Laundry Master.  The kits includes a 20ft of 
LDPE tubing per pump to connect from the chemical container to the DEMA 844P pump, and from the 
DEMA 844P pump to the fittings on the machine and 18” pickup tubes designed to accommodate 5 gallon 
buckets. 

 

For identification purposes, the pumps are identified starting with 1 and up to a possible 6 depending on 
the model.  In all cases pump number 1 is the pump that is furthest left, count up as you see pumps to the 
right of this position.  Included with the 844P Laundry Master is a sheet of product labels that can be 
adhered to the front of the Laundry Master or any other useful locations to identify the product that each 
pump is supplying. 

 

Measure the length of tubing needed for the suction side from the chemical container to the inlet of the 
pump and then cut the tubing to the proper length.  The 18” pickup tubes may be used with 5-gallon 
buckets of chemical products.  Feed the LDPE tubing through the compression nut and sleeve and into the 
pickup tube until the LDPE tubing is about a ¼” from the bottom of the pickup tube (LDPE tubing should 
not stick out through the bottom of pickup tube). Tighten the compression nut to secure LDPE tubing.  
Route the tubing to the suction side of the pump and insert into squeeze tube approximately ½”.  Secure 
the tubing together by tightening a cable tie around the squeeze tube.  Use the same procedure on the 
outlet of the squeeze tube and route the LDPE tubing to the injection feed points of the laundry machine.  
Cut off all excess tubing and keep tubing away from hot surfaces and sharp edges to prevent damage or 
leakage. 
 

At this point the Laundry Master installation is complete.  See IQ-85 OPL Laundry Control Board 
instructions for setup and programming. 

Laundry Master Operation 

Once the system has been programmed and set up to the desired configuration the 844P Laundry Master 
is ready for operation. 
 

Priming the Pumps 

There are two ways to prime a pump.  The first way, is to press the LEFT arrow on the front of the 844P. 
“P1” will be displayed indicating pump 1. Use the UP and DOWN arrows to select the desired pump. 
Press the ENTER button to start and stop the pump. Pressing the RIGHT arrow will return the 844P to 
formula select mode. If no action is taken in the pump priming mode the 844P will return to formula 
select mode after 30 seconds.  The second way, is to use the EDSM (Enhanced Digital Selection Module).  
Refer to the EDSM Instruction Sheet I-901. 
 

Emergency Stop 

At anytime, the pumps and flush can be stopped by pressing the “STOP” button on the EDSM.  When 
pressed, it will also reset the system to a starting point of the formula. 

Содержание ATLAS 844P Series

Страница 1: ...DEMA ATLAS 844P SERIES LAUNDRY CONTROL I 907 Page 1 of 17 Rev C 33371 DEMA Engineering Company 10020 Big Bend Blvd St Louis MO 63122 800 325 3362 or 314 966 3533 www demaeng com...

Страница 2: ...signals Additionally a handheld Enhanced Digital Select Module EDSM is available to allow the user to interface with the system remotely Both the STU and the EDSM are connected to the IQ 85 via a low...

Страница 3: ...ey of the laundry room or site installation should be completed in advance of starting the Laundry Master installation 1 Locate the power connection points on the laundry machine The main power to the...

Страница 4: ...lectrician A nonmetallic conduit system must be used to install the power cord For questions please contact local licensed electrical contractor Before the electrical installation it is important to u...

Страница 5: ...Locate the power terminal block inside the Laundry Master enclosure Connect hot or live wire to the terminal labeled L1 Connect the return line to the terminal block position labeled L2 The ground wir...

Страница 6: ...GREEN YELLOW SWITCH MOUNTED ON ACCESS PANEL MOTOR MOTOR 3 6 5 BROWN BLACK LOW VOLTAGE POWER CABLE W BARRER PLUG JUMPER CABLE MUST CONNECT ACROSS THE PAIR OF FLUSH SW TERMINALS 2 1 4 3 NO QTY PART NO...

Страница 7: ...ation For Formula Select Mode or Relay Mode Trigger Input Line signal Common Function of Trigger Input 1 Black White Black Stripe Signal Pump 1 2 Brown White Brown Stripe Signal Pump 2 3 Red White Red...

Страница 8: ...t the EDSM See EDSM instruction manuals for more details and STU modules to the IQ 85 by using the RJ45 patch cords that are supplied with the Laundry Master The STU is required in all installations b...

Страница 9: ...tick out through the bottom of pickup tube Tighten the compression nut to secure LDPE tubing Route the tubing to the suction side of the pump and insert into squeeze tube approximately Secure the tubi...

Страница 10: ...pump priming mode pressing the RIGHT arrow will return the 844P to formula select mode The EDSM has 30 formula capability and has a numeric display that will identify the formula See the EDSM instruct...

Страница 11: ...IQ 80 15 not shown 84 27 4 6 Foot RJ 45 Patch Cable connection between STU DSM FSM IQ 80 Accessory Replacement Parts DEMA Part No Description 25 68 20 20 ft of O D LDPE Tubing 25 68 40 40 ft of O D LD...

Страница 12: ...GNAL TRANSFER UNIT STU 84 17 2 INSTALLATION KIT PARTS QUANTITY PART NUMBER DESCRIPTION 2 83 16 1 Velcro Black Hook Loop 1 L709 1 Laundry Product Label Sheet 8 81 16 1 Tie Wrap 8 Lg 1 84 9 1 Signal Tra...

Страница 13: ...DEMA ATLAS 844P SERIES LAUNDRY CONTROL I 907 Page 13 of 17 Rev C 33371 Technical Specifications Main Power 100V 240V 50 60 Hz 1 5A Motor Solenoid Rating 24 VDC Case High Impact...

Страница 14: ...SERIES LAUNDRY CONTROL I 907 Page 14 of 17 Rev C 33371 13 14 38 15 16 18 17 20 19 21 15 6 22 23 6 22 15 24 6 15 25 20 26 26 39 HOOK POINTS UP HOOK POINTS DOWN 32 33 31 31 28 28 17 HOOK POINTS UP 39 H...

Страница 15: ...CREW 18 1 81 168 1 ENCLOSURE ASSY 19 1 81 186 11 LARGE ACCESS PANEL ASSY 20 1 1 81 186 5 81 186 7 SMALL ACCESS PANEL ASSY W TWO HOLE PLUGS SMALL ACCESS PANEL ASSY W CONDUIT FITTING 21 1 81 148 3 CONDU...

Страница 16: ...RIPTION 1 1 81 174 1 PUMP COVER 2 1 81 172 1 Detergent ROLLER ASSY 3 1 2 81 177 1 Detergent 81 176 1 Detergent SQUEEZE TUBE includes plastic connectors Plastic connectors only 4 4 25 85 2 SCREW 5 1 81...

Страница 17: ...and are not covered under warranty This warranty is extended only to the original buyer of DEMA products If products are altered or repaired without prior approval of DEMA this warranty will be void...

Отзывы: