![DEMA 606T Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/dema/606t/606t_installation-instructions-manual_2479672002.webp)
DEMA MODELS 606T
INSTALLATION INSTRUCTIONS
I-564
Pg. 2 of 6
Rev. E-41206 11/17/15
V.
SERVICING:
CAUTION: TURN OFF WATER SUPPLY BEFORE SERVICING.
A.
If unit fails to draw chemical.
1. Is more than one valve open?
2. Is the hose too long? (See Table #1)
3. Is the gun or nozzle(s) sized properly? (Refer to Section II B). Remove gun and/or nozzle(s) and turn on water. If the
injector inducts chemical, the gun and nozzle(s) are improperly sized.
4. Is the metering tip blocked? Remove tip and clear blockage.
5. Is the hose kinked or otherwise obstructed?
6. Is the spray gun fully open?
B. If unit stops drawing chemical.
1. Is the foot strainer clogged? Lift from drum and clean.
2. Are the spray nozzle(s) partially clogged? Remove and clean.
3. Is the metering tip blocked? Remove and clean.
4. Is the injector check valve clogged? Unscrew the four cover screws to take the Select-O-Spray unit off the wall.
Remove the three ball valve handles to separate the cover from the manifold. Remove the square, plastic metering knobs
to inspect the check valve ball, spring and O-ring.
CAUTION: WHEN SERVICING UNIT BE SURE THAT REPLACEMENT PARTS HAVE BEEN INSTALLED
ACCORDING TO DRAWING. BE CERTAIN CHECK VALVE PARTS ARE IN PLACE.
TABLE 2
SELECT-O-SPRAY DEMA MODEL 606T
METERING TIP SELECTION CHART
FLUID DILUTION RATIOS
METERING TIPS (100-15)
Metering Tip Color
Injection Rate for Viscosities Shown
1 cps
75 cps
200 cps
Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio
Tan
0.40
320-1
0.25
512-1
0.20
640-1
Orange
0.50
256-1
0.35
366-1
0.25
512-1
Turquoise
0.70
183-1
0.50
256-1
0.35
366-1
Pink
0.95
135-1
0.65
197-1
0.45
284-1
Light Blue
1.30
98-1
0.80
160-1
0.55
233-1
Brown
1.50
85-1
0.90
142-1
0.60
213-1
Red
1.90
67-1
1.00
128-1
0.70
183-1
White
2.20
58-1
1.30
98-1
0.80
160-1
Green
2.60
49-1
1.50
85-1
0.90
142-1
Blue
3.20
40-1
1.75
73-1
1.00
128-1
Yellow
4.85
26-1
2.25
57-1
1.10
116-1
Black
6.50
20-1
2.40
53-1
1.15
111-1
Purple
9.20
14-1
2.70
47-1
1.20
107-1
Gray
10.40
12-1
2.85
45-1
1.25
102-1
No Tip
12.80
10-1
3.50
37-1
1.55
83-1
All injection ratios are based on 40 PSI inlet water pressure and a water flow rate of 2.8 GPM.