background image

 

DEMA MODELS 606T 

INSTALLATION INSTRUCTIONS

 

I-564 

                 

 

 Pg. 1 of 6       

Rev. E-41206      11/17/15 

 
 
 
I. PARTS: 

A. Select-O-Spray 

Assembly 

B. 

2 Pcs. Foot Strainers & 1/4" ID Tubing 

C. 

4 Pcs. Mounting Screws & Anchors 

 

 
 

 

  

TABLE 

Hose I.D. 

3/8" 

1/2" 

5/8" 

Max. Length 

15 ft. 

50 ft. 

100 ft.

 

 

D. 

1 Pc. 100-15K Metering Tip Kit  

 
II.   

INSTALLATION: 

 

 
A. 

Mounting and Water Supply.   
Mount the unit on a vertical surface using the 4 screws provided through the mounting holes in the cover.  The water inlet is 
equipped with a female garden hose fitting.  The fitting may be removed to permit direct connection to 1/2" NPT pipe.  
Water supply pressure should not exceed 125 PSI.  Water temperature must not exceed 160 degrees Fahrenheit. 

 

B. Outlet 

Connection. 

Connect the discharge hoses to the outlet garden hose fitting.  Spray guns, spray nozzles or foaming wands may be used on 
the hose outlets, note that the Select-O-Spray is designed to operate with nozzle flow rates not less than 4 GPM total at 40 
PSI.  When a spray gun or nozzle is used, hose lengths must not exceed those shown in Table 1.  Hoses, spray guns and 
foam wands are available through Dema.  See the parts list on page 5, under Optional Accessories for various styles.

 

 

C. Chemical 

Supply. 

WARNING:  USE CARE WHEN HANDLING HAZARDOUS CHEMICALS. 

 

Place the chemical container in a convenient location not more than six feet below the Select-O-Spray.  (Greater lifts will 
reduce injection capabilities).  The top of the container should not be above the Select-O-Spray.  Cut the vinyl tubes to any 
convenient length that will allow the tubing to reach the bottom of the container.  Drop the tubing ends with the strainers into 
the chemical containers.  Push the other tubing ends over the chemical inlet barbs located on the sides of the unit. 

 

 

 

III.   

FEED RATE ADJUSTMENT:    

Model 606T: 
The chemical feed rate is controlled by a metering tip screwed into the metering barb on the side of the unit.  The feed rates can be 
changed by using a different size metering tip, which is available through Dema (See parts list on page 5).  To select a proper size 
metering tip for the desired dilution ratio refer to Table 2.

 

 

IV.   

OPERATION:     
A.

 

Select-O-Spray permits the operator to select one of two chemicals or clear water rinse by opening and closing the 
appropriate valve.  Only one valve should be opened at any time.  If two valves are opened simultaneously, the injector will 
not induct chemical. When using a spray gun or foaming wand make sure that the gun on the end of the hose is in the full 
open position when inducting chemical.

 

 

 
 
 
 
 

This product is designed only to be used as described in this instruction sheet.  Adhere to all warnings and 
cautions identified in this document.   

 

WARNING: 

Installations must conform to all local and national plumbing codes and use 

approved backflow prevention and pressure relief devices where required. 
 

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER 
IS NOT IN USE. 

Always read SDS for all chemicals used and follow personal protective guidelines.

 

Содержание 606T

Страница 1: ...bilities The top of the container should not be above the Select O Spray Cut the vinyl tubes to any convenient length that will allow the tubing to reach the bottom of the container Drop the tubing ends with the strainers into the chemical containers Push the other tubing ends over the chemical inlet barbs located on the sides of the unit III FEED RATE ADJUSTMENT Model 606T The chemical feed rate ...

Страница 2: ...nifold Remove the square plastic metering knobs to inspect the check valve ball spring and O ring CAUTION WHEN SERVICING UNIT BE SURE THAT REPLACEMENT PARTS HAVE BEEN INSTALLED ACCORDING TO DRAWING BE CERTAIN CHECK VALVE PARTS ARE IN PLACE TABLE 2 SELECT O SPRAY DEMA MODEL 606T METERING TIP SELECTION CHART FLUID DILUTION RATIOS METERING TIPS 100 15 Metering Tip Color Injection Rate for Viscosities...

Страница 3: ... corrosion improper voltage supply physical abuse or misapplication Rubber and synthetic rubber parts such as O rings diaphragms squeeze tubing and gaskets are considered expendable and are not covered under warranty This warranty is extended only to the original buyer of DEMA products If products are altered or repaired without prior approval of DEMA this warranty will be void Defective units or ...

Страница 4: ...TIONS I 564 Pg 4 of 6 Rev E 41206 11 17 15 WATER INLET METERING LOCATION CLEAR VINYL SUCTION TUBE WITH FOOT STRAINER WATER CHEMICAL SOLUTION OUTLET GARDEN HOSE OUTLET CHEMICAL METERING LOCATION TIP VALVE 1 TIP RINSE CLEAR CHEMICAL VALVE 2 ...

Страница 5: ...PT Pipe x 5 1 5 Lg 9 66 99 9 Elbow Hose Barb 10 63 47 3 8 NPT Inlet Adapter 11 65 18 1 3 8 NPT Outlet Adapter NO PART NO DESCRIPTION 12 100 12 Vinyl Tubing I D x 8 LG 13 61 107 2 Ceramic Weight 14 24 11MP Foot Strainer 15 292QD Foam Wand w Quick Disconnect 16 40 14QD Heavy Duty Spray Gun w Quick Disconnect 17 40 14HD Heavy Duty Spray Gun 18 44 3 Hose Black 25 x I D 19 44 3RG Hose Red Spring Guard ...

Страница 6: ...eq d 2 100 15 Metering Tip Specify Color 3 24 62 SP Check Valve Repair Kit 4 24 25S O Ring 5 24 24P Check Valve Ball 6 24 23 2 Check Valve Spring 7 24 34 7 Check Valve Core 8 25 29S O Ring 9 24 68 Injector Body P203C Series NO PART NO DESCRIPTION 10 100 15K Metering Tip Kit P203CTC INJECTOR BREAKDOWN 6 9 8 7 2 10 4 5 3 1 ...

Отзывы: