I-229
Pg. 2 of 3
Rev. A0600
DEMA MODEL 163CH HIGH CAPACITY PROPORTIONER
INSTALLATION INSTRUCTIONS
Table 1
163CH (2.5 GPM Flow rate, 3/8” barb and tubing)
Injection Rates For
Viscosities Shown
1 cps
75 cps
200 cps
Metering Tip Color
Oz/Gal
Ratio
Oz/Gal
Ratio
Oz/Gal
Ratio
Clear
0.66
195-1
.027
470-1
.14
903-1
Purple
1.01
127-1
.041
315-1
.33
393-1
Yellow
1.53
83-1
1.03
124-1
.86
148-1
Green
2.52
51-1
1.64
78-1
1.44
89-1
Pink
3.53
36-1
2.04
63-1
2.09
61-1
Turquoise
5.73
22-1
3.24
40-1
2.92
44-1
Black
6.72
19-1
3.88
33-1
3.34
38-1
Gray
8.95
14-1
4.98
26-1
4.04
32-1
Red
12.34
10-1
6.22
21-1
4.67
27-1
Blue
14.00
9-1
7.28
18-1
4.99
26-1
Brown
18.68
7-1
9.02
14-1
5.35
24-1
White
24.45
5-1
10.35
12-1
5.53
23-1
Orange
30.97
4-1
11.86
11-1
5.88
22-1
Light Blue*
38.26
3-1
13.31
10-1
6.22
21-1
Tan*
53.96
2.5-1
15.21
8-1
6.49
20-1
No Tip
66.07
2-1
18.61
7-1
7.07
18-1
Note: All induction rates are based on a water pressure of 40 psi.
* These tips are not included in the standard tip pack.
-
1 cps (centipoise) is equal to the viscosity of water, 75 cps is approximately equal to the viscosity of 10 weight motor oil, and 200
cps is approximately equal to the viscosity of most dishwashing detergents.
-
Injection rate can be doubled with no tip by using 1/2 in. I.D. inlet tubing. Use a short piece of 3/8 in. I.D. tubing on proportioner
and foot valve barbs for a bushing.
Содержание 163CH
Страница 3: ...I 229 Pg 3 of 3 Rev A0600...