background image

WARNING

: Do not connect this heat alarm to any device other than 

another 205-series alarm or other compatible Numens device (see 

datasheet). Connecting anything else may prevent this heat alarm from 

working properly. 
There is no limit to the number of units that can be interconnected using the 

wireless interconnection function.  

Units must be configured into a Group for the interconnection function to 

operate. 

When configured as a Group, the wireless function will operate automatically 

once a fire is detected in any unit. 

NOTE: Units should be interconnected within only one family residence, otherwise nuisance 

alarms may occur when a unit activates or is tested in another residence. 

Group Configuration 

1. 

Activate your heat alarm (see above).  

2. 

Ensure there are no Battery Low fault conditions on the units to be 

connected as a group. 

3. 

Enter Group mode by pressing and releasing the Test/Hush button 

5 times within 5 s. The sounder will emit a short beep and the red LED 

will flash every 0.5 s. Group mode configuration will last 50 s (unless 

cancelled earlier). 

4. 

To add a unit to the Group, press and release the Test/Hush button on 

the second unit twice within 2 s. The red LED will flash every 0.5 s. The 

sounder on the connecting unit will emit a short beep to confirm 

connection to the Group. 

5. 

Repeat Step 4 to add additional units to the Group. 

NOTE: Group configuration must be completed within 50 s, after which time all units will 

return to the normal condition. 

6. 

When all units are added to the Group, press and release the Test/Hush 

button on the first unit to end the Group configuration mode. 

Remove a Unit from a Group 

To remove a unit from the Group, press and release the Test/Hush button 

8 times within 5 s. The sounder will emit two short beeps and the red LED will 

flash twice to confirm removal from the Group. 

Test the Heat Alarm(s) 

Stand-alone Heat Alarms 

1. 

Press and hold the Test/Hush button for 3 s. 

2. 

Check the sounder operates (0.5 s on / 0.5 s off) and the red LED flashes 

every 1 s. 

3. 

Release the Test/Hush button to silence the alarm and resume normal 

operation. 

WARNING

: The heat alarm has a loud alarm signal. Use hearing 

protection when testing. 
 

Interconnected Units 

1. 

Press and hold the Test/Hush button for 3 s.  

2. 

Check the sounder operates (0.5 s on / 0.5 s off) and the red LED flashes 

every 1 s. 

3. 

On the interconnected units, check the sounder operates (0.5 s on / 0.5 s 

off) and the red LED flashes every 40 s. 

4. 

Release the Test/Hush button to silence the alarm and resume normal 

operation. 

NOTE: It may take up to 10 s for the interconnected units to silence.

 

5. 

Repeat Steps 1 ~ 4 for each unit. 

 

Normal Operation

 

 

Once installed and activated, your heat alarm will immediately start monitoring 

for excessive heat. If the sounder in the device operates, check for a fire and 

execute your safety plan. 
 

Hush (Alarm Condition) 

WARNING

: Before using the hush feature, identify the heat source and 

be certain that safe conditions exist. 

If investigation of the alarm signal is likely caused by a known nuisance source 

(such as excessive cooking heat), the Test/Hush button can be pressed to 

silence the sounder for 9 min. 

WARNING

: If the temperature is too high, the hush function will not 

silence the alarm sounder.  

After the Hush time has expired, the device will return to normal sensitivity. If 

excessive heat is still present, the alarm will re-activate. The hush feature can 

be used repeatedly. 

 

Care and Maintenance

 

 

Weekly Tests 

1. 

Press and hold the Test/Hush button for 3 s on the heat alarm. 

2. 

Check the sounder operates with a loud pulsating sound, and the red 

LED in the Test/Hush button flashes rapidly. 

WARNING

: The heat alarm has a loud alarm signal. Use hearing 

protection when testing. 

3. 

Where installed, check the activation of interconnected units (see above). 

WARNING

: Never use a naked flame of any kind to test your heat 

alarm. You may set fire to and damage the device, as well as your 

home. The built-in Test feature accurately tests all alarm functions. 
If the unit fails to operate correctly, contact your supplier or Numens (see 

below). 

Annual Maintenance 

Vacuum or carefully clean the heat alarm with a dry or damp soft cloth and 

ensure the sensor openings are free from dust and lint. Do not use solvents. 

DO NOT PAINT

 this product. 

Battery Replacement 

The battery for model 205-007 is not user-replaceable. Once the battery is 

depleted, replace the heat alarm. 
For other models, remove the unit from the base and replace the battery with 

an approved model (see Service below). 

 

Service

 

 

For service or repair, return the unit intact to the supplier or to Numens (see the 

address at the end of this manual), stating the reason for the return and details 

of any fault. 
The battery is replaceable by the user (excluding Model 205-007) and may be 

purchased from general hardware stores. Use only the specified batteries. 

Lithium

: Huiderrui CR123A 

When replacing the battery, check that the battery is installed in accordance 

with the polarity markings (+, 

) shown in the battery compartment. To ensure 

the battery is correctly fitted and the heat alarm is functioning correctly, test the 

heat alarm (see 

Care and Maintenance

, above). 

 

References

 

 

Reference 

Description 

31-0094 

205 DC heat alarm datasheet 

 

 

Models

 

 

Model 

Features 

205-007 

Test, hush, 10-year battery 

205-008 

Test, hush, 5-year battery, wireless interconnection 

205-009 

Test, hush, user-replaceable 10-year battery 

 

 
 
 
 
 
 

Disposal

 

 

This product is designed to work reliably for 10 years after 

the installation date. Smoke alarms and replaceable 

batteries should not be disposed of as land-fill. Please 

dispose in an environmentally friendly manner, for example at your local authority 

recycling centre. 

WARNING

: This is an important document. Retain it for the life of the 

device. 

 
 
 
 
 
 

Limited Warranty

 

 

To protect your rights, we encourage you to keep the original of the purchase 

receipt as proof of purchase. No guarantee can be offered without the original 

the purchase receipt. 

 

Deltronic Security AB (Deltronic) guarantees you as a buyer that the smoke 

alarm will come to be free from defects in material, workmanship or 

construction below normal use for a period of:2 years. This guarantee is non-

transferable and not valid for replaceable batteries. Our liability to you under 

this warranty, is limited to repairing or replacing parts that we find to be 

defective in materials, execution or design. This is free of charge for you, 

contact us or send enter the item with an error description and proof of 

purchase date in a letter or package with paid shipping to the address below, 

in the case of replaceable batteries attach these to the side. The terms of this 

warranty do not apply in the following circumstances: if the smoke alarm has 

been modified, disassembled, contaminated, damaged, neglected or 

otherwise misused or altered after the date of purchase or if it does not work 

due to incorrect placement / installation or if damage was caused by the 

designated instructions were not followed. We would like to draw your 

attention to the fact that we do not replace damage to unit or degradation in 

service life if the smoke alarm has been in alarm mode for a long time and / or 

saved property and life. 

 

Deltronic's liability, arising from the sale of this smoke alarm or under the 

terms of this warranty, may under no circumstances exceed the cost of 

replacing the same. 

 

Deltronic is under no circumstances responsible for damage or consequential 

damage that occurs due to the smoke alarm failing to warn under this or any 

other warranty, express or implied or for damages caused by failure to follow 

the instructions given. This warranty does not affect your statutory rights. 

 
 
 
 
 

Содержание Numens 205 Series

Страница 1: ...fault is detected in the heat sensor the heat alarm will emit a short audible signal every 40 s sounder and a single flash of the red LED indicator midway between the audible indications Test Hush Button Test When in the Normal condition pressing and holding the Test Hush button for 5 s will activate the heat alarm to check its operation The alarm will sound and the red LED will flash every 1 s Re...

Страница 2: ...s In an environment of between 0 50 C and 10 90 relative humidity non condensing Dusty or dirty areas Insect infested areas WARNING Hazardous levels of smoke and toxic gas can build up before a heat alarm might operate Where life safety is the primary requirement in the event of a fire smoke gas or combination alarms usually provide earlier warning than heat alarms alone For complete coverage smok...

Страница 3: ...ere installed check the activation of interconnected units see above WARNING Never use a naked flame of any kind to test your heat alarm You may set fire to and damage the device as well as your home The built in Test feature accurately tests all alarm functions If the unit fails to operate correctly contact your supplier or Numens see below Annual Maintenance Vacuum or carefully clean the heat al...

Страница 4: ...deltronic se 2020 09 30 2019 Ambest Electronics Ningbo Co Ltd All rights reserved All specifications and other information shown were current at the date of publication and subject to change without notice See all products at www numens com Numens 55 Yunhui Road Yunlong Town Yinzhou District Ningbo Zhejiang China 315121 Helpline 86 574 8281 7218 ...

Отзывы: