Delton 1000 Скачать руководство пользователя страница 2

intermittently.  Therefore,  the  detector  can  detect  whether  the  wire  has 
current and whether there is line failure. 

(2)

  Table for pliers and corresponding lights 

Identification of pliers 

symbol of light   

R

Red

 

only R-S lights up 

S

yellow

 

R-S and S-T light up 

T

Blue

 

only S-T lights up 

VI.

Replacing Battery

Please pay attention to the polarity of battery!

1. Before  replacing  battery,  must  move  pliers  away  from  the  detected  wires. 

Don

t replace battery during testing. 

2. Press key 

OFF

 to shut off the detector (Figure A) 

3. Loose a screw on the rear cover of battery and then open the 

rear cover (Figure B) 

4. Replace  with  brand-new  qualified  batteries.  Please  pay  attention  to  the 

polarity and specifications of battery (Figure C). 

5. Close the rear cover and tighten the screw (Figure D). 
6. Press  key 

ON

.  Check  if  the  detector  can  start  normally,  otherwise  repeat 

step 3 or check if the capacity of battery is sufficient. 

VII. FAQ

failures 

possible reasons 

solutions 

Fail 

to 

be 

power-on  (the 

LCD  backlight 

is 

off, 

no 

display)

 

no battery

 

Install 

the 

qualified 

batteries

 

violate  the  specifications  of 

battery 

Replace with the batteries 

up to specifications 

low battery capacity

 

replace  with  brand-new 

qualified batteries

 

reverse placement of battery

 

Reinstall 

the 

batteries 

according  to  their  correct 

polarities 

loose contact of batteries 

adjust 

the 

place 

of 

batteries  and    reinstall 

them

 

Continue: 

failures 

possible reasons 

solutions 

Fail 

to 

be 

power-on 

(the 

LCD  backlight 

is 

off, 

no 

display)

 

fail  to  close  the  rear  cover 

of battery

 

close  the  rear  cover  of 

battery tightly

 

loose contact or breakage of 

power lines in batteries

 

Re-weld or replace power 

lines

 

Loose  contact  of  power-on 

button

 

Replace  the  power-on 

button

 

bad membrane switch 

replace  the  membrane 

switch 

bad LCD 

Repair or replace LCD 

bad  elements  on  circuit 

board

 

Repair  or  replace  the 

circuit board

 

the 

LCD 

backlight  is  on 

after 

being 

power-on, 

but 

no display

 

low battery capacity 

Replace 

with 

the 

brand-new 

qualified 

batteries 

bad LCD 

Repair or replace LCD 

bad  elements  on  circuit 

board

 

Repair  or  replace  the 

circuit board

 

Be 

power-on 

and  conduct  the 

detection 

normally,   

low battery capacity 

Replace 

with 

the 

brand-new 

qualified 

batteries 

bad LCD 

Repair or replace LCD 

Continue: 

failures 

possible reasons 

solutions 

but  the  display 

of 

LCD 

becomes dark 

bad  elements  on  circuit 

board

 

Repair  or  replace  the 

circuit board

 

Be 

normally 

power-on,  but 

fail  to  conduct 

the detection

 

The  three  detected  phase 

wires have no current 

Not 

the 

problem 

in 

detector, 

the 

phase 

sequence 

can

be 

detected until the detector 

is electrified 

Pliers  fail  to  clamp  the 

detected phase wires 

Re-clamp the  phase  wires 

based  on  the  manual

requirement 

The  lead  wire  of  pliers  is 

broken 

Replace  the  lead  wire  of 

pliers 

low battery capacity 

Replace 

with 

the 

brand-new 

qualified 

batteries 

bad LCD 

Repair or replace LCD 

bad  elements  on  circuit 

board

 

Repair  or  replace  the 

circuit board

 

VIII. Assembly Drawing

IX.

Packing list

1

detector 

  1 piece       

2

carrying box          1piece   

3

strap     

  1 piece 

4

"AA" size Mg-alloy batteries 

R6P

      2 pieces 

5

user manual          1 piece     

6

warranty card 

  1 piece 

7

certification          1 piece 