7
ELECTRICAL SCHEMATIC
AIR AND REFRIGERANT FLOW SCHEMATIC
Figure 1
Figure 2
HEAT EXCHANGER
REHEATER
AUX. CONDENSER
AIR OUTLET
SEPARATOR
EVAPORATOR
CHILLER
DRAIN OUTLET
AIR INLET
LIQUID RECEIVER
/ FILTER DRYER
CONSTANT PRESSURE
EXPANSION VALVE
REF. COMPRESSOR
ON/OFF SWITCH
WITH RUNNING LAMP
R
2
5
6
PTC STARTER
S
M
COMP.
1PH
C
OVERLOAD
PROTECTOR
ENGINEERING DATA
SCFM
10
15
SPECIFICATIONS
Rated Capacity
a
- (scfm)
10
15
Inlet /Outlet Connections - (inches)
3/8
3/8
Dimensions
Height - (inches)
15.4
15.4
Length - (inches)
12.6
12.6
Width - (inches)
12.6
12.6
Power Supply - (V/Ph/Hz)
115/1/60
115/1/60
Refrigerant Compressor Rating - (hp)
1/8
1/7
Input Power - (kW)
0.21
0.24
Refrigerant Type
b
R-134a
R-134a
MINIMUM - MAXIMUM OPERATING CONDITIONS
Min.-Max. Inlet Air Pressure (compressed air at inlet to dryer)
30 - 250 psig
30 - 250 psig
Min.-Max. Inlet Air Temperature (compressed air at inlet to dryer)
40°F - 122°F
40°F - 122°F
Min.-Max. Ambient Temperature
40°F - 113°F
40°F - 113°F
a
Rating conditions are 100°F inlet temperature, 100 psig inlet pressure, 100% inlet relative humidity, 100°F ambient temperature @ 60Hz. Per CAGI ADF-100
b
Refer to dryer data plate for refrigerant charge.