To facilitate this, there is a power port to the left of the float switch cable into which a 10V power source can 

be connected. This power supply can be linked to either a simple timer or to an aquarium computer and 

used to hold off the reactor from dosing during part of the 24-hour cycle. 

 

When the 10V supply is applied the activity LED H will flash red/green and the controller prevents the supply 

pump from adding any water to the reactor however all of the other pumps, solenoids and functions 

continue to operate as normal. 

 

It will be necessary to allow for the hold off period when calculating the flow rate required, for example; if 

the normal flow rate required was 60 litres per day for continuous running and the reactor was stopped from 

dosing for 12 hours of the 24-hour period, then it would be necessary to set the flow rate to 120lts. 

 

Running the Twin-Tech reactor for the first time 

 

You should now be ready to run the reactor for the first time, go through the following checks. 

 

 

The unit is completely full of water and bled of any air in the pump. 

 

The end of the outlet hose is in the sump or tank 

 

The CO2 system is connected, and the pressure is set to 1.5-2.0 bar.  

 

AT THIS STAGE LEAVE THE MAIN VALVE ON THE CO2 BOTTLE CLOSED. 

 

The feed pump is in the tank water. Squeeze the filter sponge to remove any air. 

 

All wires are connected to the pumps and the float switch is plugged into the controller. 

 

Set the initial flow rate to 50lt/day 

 

Set the recirculation rate to 50% 

 

Set the initial bleed rate to 50lt/day. 

 

Plug in the power 

 

The main LED will display a series of numbers as the system initiates and then the recirculation pump will 

start to run.  

 

IMPORTANT:

 At this stage you should be able to observe the water recirculating around the reactor. If this is 

not the case, then you have not correctly removed all of the air from the recirculation pump body. Remove 

the power from the controller and bleed the reactor again. 

 

If the water is observed circulating around the reactor then you will also see the blue light on the controller 

illuminated as the system requests CO2. Now open the main valve on the CO2 bottle and you will observe a 

large pocket of gas starting to form in the top of the gas chamber. This will slowly grow until the bottom of 

the pocket reaches the level of the float switch and should happen over a period of 60-120 seconds.  

 

If the gas pressure from the regulator is too low so that it takes more than 4 minutes to trigger the float 

switch, then the unit will alarm. Increase the pressure slightly on the regulator and briefly unplug/re-plug in 

the controller and it will start again and refill correctly. 

 

If the pressure is too high, then the pocket will fill too quickly which may introduce too much gas in during 

normal operation when the system is only asking for top up additions. 

 

The reactor is now running normally

.  

 

Observe the system operating and you will see the feed water come on every 5 minutes or so, this will allow 

the CO2 to dissolve in the new volume of water. The pocket of gas will get smaller until it reaches the upper 

float position, at which point it calls for more gas, the blue LED will come on as gas is added, refills and 

triggers the float again, the blue light goes off. 

 

Generally, you will not observe the de-gas cycle operating as it will happen automatically in the background. 

 

Measuring the dKH of the effluent. 

 

Leave the reactor to run for a couple of hours and then measure the dKH coming out of the effluent. This will 

normally be in the range of 40-60dKH.  

 

Most test kits only read up to 16dKH for a full syringe of reagent, however if you add a second syringe it is 

32dKH, and so on. Keep going until you reach the end point and then all of the numbers together. 

 

Содержание Twin-Tech 10000

Страница 1: ...INSTALLATION INSTRUCTIONS FOR THE DELTEC TWIN TECH CALCIUM REACTORS...

Страница 2: ...the float switch and triggers the solenoid valve to add more gas to replenish the bubble Features This innovative reactor has several unique features providing simplicity of control but also relating...

Страница 3: ...ation pump speed 5 Non return valve E Process active complete 6 Solenoid valve F Increase button for items marked 7 Float switch G Decrease button for items marked 8 CO2 bottle and Regulator H Activit...

Страница 4: ...the pipe in the middle of the reactor whilst filling Note You have an option to fill the larger media chamber with water at this stage whilst the lid is removed Step 5 Replace the lid on the media cha...

Страница 5: ...ed pump connection green line Recirculation pump connection red line Connect the cables and pumps in the positions shown on the layout diagram on page 2 but do not plug the power supply into the mains...

Страница 6: ...ngth of the bleed nipples with short lengths of hose that extend into a container above the height of the reactor Put the end of the outlet pipe into the same container Apply power to the control pane...

Страница 7: ...adding small amounts of water to the reactor during the final filling stage B Water Flow The LED display gives a readout of the total water effluent that passes through the reactor in a 24 hour period...

Страница 8: ...the pump but will normally take about 1 2 minutes to complete F G Up and down buttons These are self explanatory and used to control the levels up and down of functions B C and D above H Activity ind...

Страница 9: ...this is not the case then you have not correctly removed all of the air from the recirculation pump body Remove the power from the controller and bleed the reactor again If the water is observed circu...

Страница 10: ...omes stable this is now your dialled in flow rate Set the de gas volume to be the same Existing calcium reactor If you are converting from an existing calcium reactor then it is fairly easy to calcula...

Страница 11: ...uild up of inert gas released from the media On the chart below you can see the initial rapid drop from normal tank pH as the reactor is first switched on and the 2 peaks B C just before each degas cy...

Страница 12: ...ing solution such as D D Ezyclean through this component and collect into a separate container You can either used the supplied feed pump continuously triggering the pump run function or another suita...

Отзывы: