The correct calcium level is a vital requirement in keeping and growing corals successfully in marine aquaria. 
The calcium level should be kept above 400 and preferably at 470/500 mg/litre. 

With the Deltec 

calcium reactor

 it is possible to adjust and  control  the  calcium level in  a simple  manner. 

The Deltec  

calcium reactor

 consists of  

-

a cylindrical transparent container

-

bubble counter

-

solenoid valve (optional)

-

non return valve

-

provision for pH electrode

-

micro filter

Installation and operating instruction 

Wash the granulate to be used 

thoroughly

 before filling it into the  Deltec 

calcium reactor

. The granulate 

must be free of all floating matters and other foreign particles.  

The Deltec  PF Calcium reactors operate on the fluidized bed principle; it is therefore important to use only 
Deltec  Hy Carb Media to achieve best results. 

-

Remove the reactor head by turning it anticlockwise.

-

Remove the strainer plate and sponge.

-

Fit the cap No. 12 over the central feed pipe No. 15 to prevent media to enter the pipe.

-

Fill the Vessel up to the fill line.

-

Refit the strainer plate with the sponge pointing downwards.

-

Clean the O-Ring and all sealing surfaces and grease the O-Ring with silicon spray or silicon grease.

-

Refit the reactor head and turn it clockwise

Place the Deltec 

calcium reactor

 on an even surface, close to the filter sump or the aquarium. 

Please note 

The  bubble  counter  should  be  filled  with  tap  water.  To  do  this,  loosen  the  cap  nut  of  the  pressure  fitting, 
remove the hoses, withdraw the bubble counter and fill it under a tap. 

Connecting the reactor 

-

Connect a flexible CO2 supply hose to the bubble counter (or the solenoid valve if supplied).

-

The micro filter 

should

 be connected to a water supply either from a separate

pump or else to a bypass of the main aquarium pump.

-

Open the tap at the micro filter and allow the Deltec 

calcium reactor 

to be filled.

-

Start the circulation pump

-

To ease bleeding, raise the outlet hose higher than the reactor body for a short period.

Open and set the CO2 supply to app. one bubble per second. Adjust the tap at the micro filter to a drip (app. 
2-4 drops/second, coming out at the outlet hose).

Please note 

To adjust the DKH (calcium level) either increase the CO

2

 or decrease the water flow. Avoid excessive supply 

of  CO

2

.  Please  ensure  that  sufficient  time  is  allowed  for  any  adjustments  to  take  effect  before  testing  the 

water.  The Deltec 

calcium reactor

  can  also  be  operated  automatically  by fitting  a  pH  electrode instead  of 

the red plug at the top of the Deltec 

calcium reactor

. A suitable pH controller would control the pH value by 

opening/closing the solenoid valve. For normal operation the pH level should be between 6,2-6,5.  

To get best results, it is important to check the correct water flow and CO

2

 supply on a regular basis and the 

resulting DKH level at the outlet. 

Important 

Never restrict or block the water flow from the outlet hose, since this could lead to on increase of pressure 
inside the reactor. 

technical data 

 dimensions (l/w/h) app. 

quantity app. 

for aquaria up to  tube ø 

PF 501 

200 x 170 x   500 mm 

2,9 kilos 

1000 ltr. 

110 mm 

PF 601 

260 x 210 x   550 mm 

8,7 kilos 

2000 ltr. 

160 mm 

PF 601S 

305 x 255 x   550 mm 

14,0 kilos 

3000 ltr. 

200 mm 

PF 1001 

375 x 305 x 1080 mm 

34,0 kilos 

5000 ltr. 

200 mm 

PF 1370 

480 x 350 x 1300 mm 

97,0 kilos 

20000 ltr. 

300 mm 