- Never put your fingers into the pump’s suction or pressure side with the pump 
connected to mains electricity.  
- When using flexible hoses make sure that they are suitable for the pumps 

performance and do not leach out dangerous substances into the water.  
- When using non return valves ensure proper function, otherwise there is great 
danger of the pumps running dry.  
- If required, use a strainer with app 2-3 mm opening on the suction side. When 

using finer filtration (sponges etc) make sure that they are always cleaned at short 
intervals, to prevent cavitations and possible damage to the pump.  
- Do not operate the pump with a shut off valve on the suction side, partly or fully 
closed.  

 

 

Installation of the controller 

 

Install the controller in a dry, suitably vented place, away from water, dampness 

and other heat sources like sunlight, artificial light etc.  

 

 

Starting the pump 

 

Check that the power supply is suitable for the pump. Refer to the pumps label.  
Use the pump with an electric circuit breaker.  
 

Overload protection 

 

E-

Flow 

pumps are protected against overloading. If the impeller is blocked the 

pump is switched off automatically. If the cause of the blockage is removed the 

pump can be restarted or will start on its own.  
 

Power cut new start 

 

After a power cut or the pump having being switched off, the pump will assume its 

old setting when the power comes back on.  

 
 
 
 

 
 
 
 
 
 
 
 
 
 