background image

Deltec Internal Skimmer Black Edition 

 

 

The Black Edition skimmers are

 designed to 

operate in external filter sumps. 

 

The Pump 

The BE 1.5

i

 operate with the E-Flow 4S pump 

The BE 3

i

 operate with the E-Flow 8S pump 

The BE 7

i

 can operate with the following pumps: 

1. 

Deltec E-Flow 12S  

2. 

Abyzz A200 Abschäumer 

 
All pumps includes a "soft start", this means the rotor will be slowly accelerated to it´s set 

at the controller power stage. Through this slow acceleration is starting the Pump, even 
under difficult conditions, guaranteed. The choice of the power stage by pressing the + and 

- buttons is carried out at the controller.  
  

The transformer as well as the controller have to be placed in a dry and ventilated place to 
prevent any possible damage through moisture or water. 

Damages caused this way are except from warranty. 

 

Installation 

 

For  best  performance  the  water  level  in  the  filter  sump  should  be  between  180  and         

250  mm.  A  prerequisite  for  continuous  efficient  performance  is  a  constant  water  level  in 
which the skimmer operates. Ideally, a water level top up system should be used such as 

the Deltec Aquastat 1001 or better still a separate skimmer compartment in the sump. The 
water level in the skimmer compartment should be higher than in the rest of the sump. But 

within the levels recommended for the skimmer model.  
This compartment can be supplied with water from a bypass of the aquarium overflow. 

 

 

Starting the skimmer 

 

-

 

position the skimmer in the sump 

-

 

feed water into the skimmer compartment (if applicable) 

-

 

open the water level adjuster (diagram c) fully by turning it anti-clockwise 

-

 

start the skimmer pump 

-

 

close the water level adjuster until fine bubbles are visible in the area of the transition 
between the skin tube and the riser.    

-

 

initially  keep  the  foam  level  in  the  skimmer  cup  low  to  avoid  over  skimming  and 
possible flooding of the cup. 

-

 

wait a minimum of 24 hours before the final adjustment 

-

 

turn  the  water  level  adjuster  in  or  out  until  the  fine  air  bubbles  start  bursting 

approximately half way up the cups riser tube 

-

 

for dry foam turn the water level adjuster anti-clockwise 

-

 

for wet foam clockwise 

-

 

Important:

 

Never allow the pump to run dry. 

 
 

 
 

 

Содержание Black Edition 1.5i

Страница 1: ...Black Edition 1 5i 3i 7i Operating instruction Page 9...

Страница 2: ...ceptacle If the plug or socket does get wet DON T unplug the cord Disconnect the fuse or circuit breaker that supplies power to the appliance Then unplug and examine for presence of water in the recep...

Страница 3: ...tant water level in which the skimmer operates Ideally a water level top up system should be used such as the Deltec Aquastat 1001 or better still a separate skimmer compartment in the sump The water...

Страница 4: ...by means of the movable pipe no 6 in the spare parts drawing The further it is pulled out the later the emergency overflow reacts If the emergency overflow is activated no more air is sucked in the p...

Страница 5: ...zer may not be directly connected to the air valve In order to avoid water damage the ozonizer must be placed high enough to ensure that no water can penetrate it when the skimmer pump is switched off...

Страница 6: ...uired that the pumps are removed from the skimmer having first drained the body of Water Check and clean the impellor of debris If necessary soak the pump housing in white vinegar or lime scale remove...

Страница 7: ...Spare part list BE...