Deltec Internal Skimmer Black Edition
The Black Edition skimmers are
designed to
operate in external filter sumps.
The Pump
The BE 1.5
i
operate with the E-Flow 4S pump
The BE 3
i
operate with the E-Flow 8S pump
The BE 7
i
can operate with the following pumps:
1.
Deltec E-Flow 12S
2.
Abyzz A200 Abschäumer
All pumps includes a "soft start", this means the rotor will be slowly accelerated to it´s set
at the controller power stage. Through this slow acceleration is starting the Pump, even
under difficult conditions, guaranteed. The choice of the power stage by pressing the + and
- buttons is carried out at the controller.
The transformer as well as the controller have to be placed in a dry and ventilated place to
prevent any possible damage through moisture or water.
Damages caused this way are except from warranty.
Installation
For best performance the water level in the filter sump should be between 180 and
250 mm. A prerequisite for continuous efficient performance is a constant water level in
which the skimmer operates. Ideally, a water level top up system should be used such as
the Deltec Aquastat 1001 or better still a separate skimmer compartment in the sump. The
water level in the skimmer compartment should be higher than in the rest of the sump. But
within the levels recommended for the skimmer model.
This compartment can be supplied with water from a bypass of the aquarium overflow.
Starting the skimmer
-
position the skimmer in the sump
-
feed water into the skimmer compartment (if applicable)
-
open the water level adjuster (diagram c) fully by turning it anti-clockwise
-
start the skimmer pump
-
close the water level adjuster until fine bubbles are visible in the area of the transition
between the skin tube and the riser.
-
initially keep the foam level in the skimmer cup low to avoid over skimming and
possible flooding of the cup.
-
wait a minimum of 24 hours before the final adjustment
-
turn the water level adjuster in or out until the fine air bubbles start bursting
approximately half way up the cups riser tube
-
for dry foam turn the water level adjuster anti-clockwise
-
for wet foam clockwise
-
Important:
Never allow the pump to run dry.