DPM-12GM-6-P1A-FP10-F-V1 10/31/2018
17
ROCON LLC
Important Note
Priority will always be given to the settings sent from the PROFINET Master. The change
of setpoints from the user button requires:
1. PROFINET Master is not connected or,
2. PROFINET Master sends 0 to the corresponding setpoints
3. PROFINET Master got disconnected and user resets the device locally pressing
RESTART button
Individual (Standalone) Button Press Features
1. PROGRAM: Pressing PROGRAM would take the user to the setting
s. See “Menu
Features” above
2. UP: Displays the current status bits
3. DOWN: Displays the return flow from the Gun (
R
) on the lower line of the LCD
4. ENTER: Shows the firmware version, current IP, Subnet and MAC.
5. RESET: Will reset the device after the
reset time
set by the user.
6. BYPASS: Sends a Bypass Signal to the PROFINET Master/Client.
LCD Display Features
The upper line of the LCD displays the Supply Flow, and Flow related faults (if any).
The lower line displays the temperature of the Gun supply and temperature related faults
(if any).
24.7 LPM
22°C OK
6.54 GPM
71°F OK
°F:
Degree Fahrenheit, implies that the units are English
The unit of Flow is hence GPM
°C:
Degree Celsius, implies that the units are Metric
The unit of Flow is hence LPM