background image

 

Revision Oct. 2009, 07EE, SW--PW V1.14/CTL V2.14 

1-1

 

Chapter 1 Introduction 

The AC motor drive should be kept in the shipping carton or crate before installation. In order to retain 

the warranty coverage, the AC motor drive should be stored properly when it is not to be used for an 

extended period of time. Storage conditions are: 

 

CAUTION!

 

1. 

Store in a clean and dry location free from direct sunlight or corrosive fumes. 

2. 

Store within an ambient temperature range of -20

 °

C to +60

 °

C. 

3. 

Store within a relative humidity range of 0% to 90% and non-condensing environment. 

4. 

Store within an air pressure range of 86 kPA to 106kPA. 

5. 

DO NOT place on the ground directly. It should be stored properly. Moreover, if the surrounding 

environment is humid, you should put exsiccator in the package. 

6. 

DO NOT store in an area with rapid changes in temperature. It may cause condensation and 

frost. 

7. 

If the AC motor drive is stored for more than 3 months, the temperature should not be higher 

than 30 °C. Storage longer than one year is not recommended, it could result in the degradation 

of the electrolytic capacitors. 

8. 

When the AC motor drive is not used for longer time after installation on building sites or places 

with humidity and dust, it’s best to move the AC motor drive to an environment as stated above. 

Содержание VFD-E

Страница 1: ......

Страница 2: ...sing environment 4 Store within an air pressure range of 86 kPA to 106kPA 5 DO NOT place on the ground directly It should be stored properly Moreover if the surrounding environment is humid you should...

Страница 3: ...motor drive MODEL V FD007E23A INPUT 3PH 200 240V 50 60Hz 5 1A OU TPUT 3PH 0 240V 4 2A 1 6kVA 0 75kW 1HP FREQUEN CY RANGE 0 1 400Hz Serial Number Bar Code AC Drive Model Input Spec Output Spec Output...

Страница 4: ...tion factory Production week T Taoyuan W Wujiang Model 230V 3 phase 1HP 0 75kW If the nameplate information does not correspond to your purchase order or if there are any problems please contact your...

Страница 5: ...ad cover Case body Control board cover Output terminals U T1 V T2 W T3 7 5 15HP 5 5 11kW Frame C Input terminals R L1 S L2 T L3 Case body Keypad cover Control board cover Output terminals U T1 V T2 W...

Страница 6: ...01 00 to P01 02 for details Switch to ON for free run to stop refer to P02 02 Switch to ON for setting frequency source to ACI P 02 00 2 ACI terminal ACI AVI2 switch Mounting port for extension card N...

Страница 7: ...43C VFD015E23C 43C A A1 0 25 2hp 0 2 1 5kW VFD002E11T 21T 23T VFD004E11T 21T 23T 43T VFD007E21T 23T 43T VFD015E23T 43T A A2 0 25 2hp 0 2 1 5kW VFD002E11P 21P 23P VFD004E11P 21P 23P 43P VFD007E21P 23P...

Страница 8: ...the RFI jumper Therefore please make sure that main power has been switched off before cutting the RFI jumper 2 The gap discharge may occur when the transient voltage is higher than 1 000V Besides el...

Страница 9: ...rectly Remove UVW Terminal Cover For Frame B Frame C and Frame D it only needs to turn the cover light to open the cover For frame A it doesn t have cover and can be wired directly Remove Fan For Fram...

Страница 10: ...llowed Atmosphere pressure 86 106 kPa Installation Site Altitude 1000m Operation Vibration 20Hz 9 80 m s2 1G max 20 50Hz 5 88 m s2 0 6G max Temperature 20 C 60 C 4 F 140 F Relative Humidity 90 no cond...

Страница 11: ...C motor drive dust collector Air extracting apparatus Control panel CAUTION 1 Operating storing or transporting the AC motor drive outside these conditions may cause damage to the AC motor drive 2 Fai...

Страница 12: ...aw dust metal particles etc from adhering to the heatsink 8 When installing multiple AC more drives in the same cabinet they should be adjacent in a row with enough space in between When installing on...

Страница 13: ...after connecting in parallel 5 Only the same power system and capacity can be connected in parallel 6 It is recommended to connect 5 AC motor drives in parallel no limit in horsepower but these 5 dri...

Страница 14: ...0 5 98 50 0 1 97 4 5 0 18 5 2 0 20 5 2 0 20 A A2 72 0 2 83 56 0 2 20 155 0 6 10 143 0 5 63 111 5 4 39 9 5 0 37 5 3 0 21 NOTE Frame A A1 VFD002E11A 21A 23A VFD004E11A 21A 23A 43A VFD007E21A 23A 43A VF...

Страница 15: ...S2 H1 W W1 D1 D2 S1 Unit mm inch Frame W W1 H H1 D D1 D2 S1 S2 B1 100 0 3 94 89 0 3 50 174 0 6 86 162 0 6 38 152 0 5 98 50 0 1 97 4 0 0 16 5 5 0 22 5 5 0 22 NOTE Frame B B1 VFD007E11A VFD015E21A VFD02...

Страница 16: ...ame C H H1 W1 W S1 S2 D D1 D2 Unit mm inch Frame W W1 H H1 D D1 D2 S1 S2 C1 130 0 5 12 116 0 4 57 260 0 10 24 246 5 9 70 169 2 6 66 78 5 3 09 8 0 0 31 6 5 0 26 5 5 0 22 NOTE Frame C C1 VFD055E23A 43A...

Отзывы: