Chapter 6 Fault Code Information
|
VFD-B Series
6-2
Revision July 2008, BE16, SW V4.08 & V5.00
Fault
Name
Fault Descriptions
Corrective Actions
Overheating
Heat sink temperature too high
1.
Ensure that the ambient temperature falls
within the specified temperature range.
2.
Make sure that the ventilation holes are not
obstructed.
3.
Remove any foreign objects from the
heatsinks and check for possible dirty heat
sink fins.
4.
Check the fan and clean it.
5.
Provide enough spacing for adequate
ventilation. (See chapter 2)
Low voltage
The AC motor drive detects
that the DC bus voltage has
fallen below its minimum
value.
1.
Check whether the input voltage falls within
the AC motor drive rated input voltage range.
2.
Check for abnormal load in motor.
3.
Check for correct wiring of input power to R-
S-T (for 3-phase models) without phase loss.
Overload
The AC motor drive detects
excessive drive output current.
NOTE: The AC motor drive
can withstand up to 150% of
the rated current for a
maximum of 60 seconds.
1. Check whether the motor is overloaded.
2. Reduce torque compensation setting in Pr.7-
02.
3. Use the next higher power AC motor drive
model.
Overload 1
Internal electronic overload trip
1. Check for possible motor overload.
2. Check
electronic
thermal overload setting.
3. Use a higher power motor.
4. Reduce the current level so that the drive
output current does not exceed the value set
by the Motor Rated Current Pr.7-00.
Overload 2
Motor overload.
1. Reduce the motor load.
2. Adjust the over-torque detection setting to an
appropriate setting (Pr.06-03 to Pr.06-05).
GFF hardware error
CC (current clamp)
OC hardware error
OV hardware error
Return to the factory.
Communication Error
1.
Check the RS485 connection between the AC
motor drive and RS485 master for loose wires
and wiring to correct pins.
2.
Check if the communication protocol, address,
transmission speed, etc. are properly set.
3.
Use the correct checksum calculation.
4.
Please refer to group 9 in the chapter 5 for
detail information.
Содержание VFD-B
Страница 3: ...r...
Страница 28: ...Chapter 2 Installation and Wiring VFD B Series Revision July 2008 BE16 SW V4 08 V5 00 2 11...
Страница 49: ...Chapter 2 Installation and Wiring VFD B Series 2 32 Revision July 2008 BE16 SW V4 08 V5 00...
Страница 53: ...Chapter 3 Start Up VFD B Series 3 4 Revision July 2008 BE16 SW V4 08 V5 00 This page intentionally left blank...
Страница 162: ...Chapter 5 Parameters VFD B Series Revision July 2008 BE16 SW V4 08 V5 00 5 105 This page intentionally left blank...
Страница 163: ......
Страница 187: ...Appendix A Specifications VFD B Series A 4 Revision July 2008 BE16 SW V4 08 V5 00 This page intentionally left blank...
Страница 202: ...Appendix B Accessories VFD B Series Revision July 2008 BE16 SW V4 08 V5 00 B 15 Order P N 10TDT1W4C Order P N 26TDT1W4C...
Страница 203: ...Appendix B Accessories VFD B Series B 16 Revision July 2008 BE16 SW V4 08 V5 00 Order P N 50TDS4W4C Order P N 100TDS84C...
Страница 204: ...Appendix B Accessories VFD B Series Revision July 2008 BE16 SW V4 08 V5 00 B 17 Order P N 200TDDS84C Order P N 150TDS84C...