Installation

January 30, 2012

Delta Products Corporation

Support Email: 

[email protected]

Support Hotline:    1-877-442-4832 or 1-626-369-8019

1

2

3

4

Power 

Connection*

To Internet Connected 

Network Port

Connect the

cable to one 

of the connectors 

at A or B

RS485 connector on SOLIVIA AP 

or EU grid-tie inverters

A

B

RS485 connector in SOLIVIA NA 

grid-tie inverter wiring box

*

U.S. power receptacle shown. 

The SOLIVIA GW comes with an 

international AC / DC adapter which 

will operate in many countries 

worldwide.  The input voltage range 

must be between 100V - 240V AC.

NOTE:  When installing 

the monitoring device to a 

SOLIVIA NA inverter, the 

Ethernet cable must be 

routed through a 1/2“ conduit 

on the SOLIVIA NA inverter 

wiring box.  Please check 

the inverter user manual for 

further information.

LED Status

LED Name(s)

Color and Condition

Description

Power

Green - Solid

Gateway Powered On

10/100 MB LINK

Green - Solid

100 Mb Link Established

10/100 ACTIVITY

Green - Flashing Once Per Second

Data Transfer

ERROR

OFF

Normal Operation (If ERROR LED is lit in combination with a solid or fl ashing 

green LED below, there is a problem)

ERROR and RS485 ACTIVE

ERROR Steady Red and RS485 ACTIVE Flashing Green Device Error

ERROR and RS485 ACTIVE

ERROR Flashing Red and RS485 ACTIVE Flashing 

Green

•  No DHCP response or

•  Wrong MAC Address or Inverter ID entered in the confi guration process or

•  Confi guration Wizard setup was not completed

RS485 ACTIVE

Green - Solid

Connection to the inverter is successful

RS485 ACTIVE

Green - Flashing (every 200 sec.)

Communication with the inverter

RSR85 ACTIVE

OFF

No connection to the inverter

Delta Energy Systems (Germany) GmbH 

Support Email: 

[email protected]

Support Hotline:    0180 16 SOLAR (76527)

www.solar-inverter.com

www.deltaenergysystems.com

Monday  to  Friday  from  8  am  to  5  pm  (except  official  Bank 

Holidays) (3.9 ct/min.)

This cable length 

should not exceed 

1,000 meters or 

3,000 feet. 

This cable length 

should not exceed 

100 meters or 

300 feet. 

DB25 to RJ45 

Adapter (included 

with the gateway)

USA & CANADA

EUROPE

Troubleshooting RS485 communication

1. Try a different Ethernet cable if the network or inverter connection is not established. There may be a broken wire in the cable.

2. Verify that the gateway is powered up - Power LED should appear solid green.

3. If the length of the cable is greater than 65 meters or 200 feet, verify that shielded cable is used.

Delta Energy Systems (Australia) Pty. Ltd.

Support Email: 

[email protected]

Support Hotline:    61 3 8414 8295
 

AUSTRALIA