Installation
January 30, 2012
Delta Products Corporation
Support Email:
Support Hotline: 1-877-442-4832 or 1-626-369-8019
1
2
3
4
Power
Connection*
To Internet Connected
Network Port
Connect the
cable to one
of the connectors
at A or B
RS485 connector on SOLIVIA AP
or EU grid-tie inverters
A
B
RS485 connector in SOLIVIA NA
grid-tie inverter wiring box
*
U.S. power receptacle shown.
The SOLIVIA GW comes with an
international AC / DC adapter which
will operate in many countries
worldwide. The input voltage range
must be between 100V - 240V AC.
NOTE: When installing
the monitoring device to a
SOLIVIA NA inverter, the
Ethernet cable must be
routed through a 1/2“ conduit
on the SOLIVIA NA inverter
wiring box. Please check
the inverter user manual for
further information.
LED Status
LED Name(s)
Color and Condition
Description
Power
Green - Solid
Gateway Powered On
10/100 MB LINK
Green - Solid
100 Mb Link Established
10/100 ACTIVITY
Green - Flashing Once Per Second
Data Transfer
ERROR
OFF
Normal Operation (If ERROR LED is lit in combination with a solid or fl ashing
green LED below, there is a problem)
ERROR and RS485 ACTIVE
ERROR Steady Red and RS485 ACTIVE Flashing Green Device Error
ERROR and RS485 ACTIVE
ERROR Flashing Red and RS485 ACTIVE Flashing
Green
• No DHCP response or
• Wrong MAC Address or Inverter ID entered in the confi guration process or
• Confi guration Wizard setup was not completed
RS485 ACTIVE
Green - Solid
Connection to the inverter is successful
RS485 ACTIVE
Green - Flashing (every 200 sec.)
Communication with the inverter
RSR85 ACTIVE
OFF
No connection to the inverter
Delta Energy Systems (Germany) GmbH
Support Email:
Support Hotline: 0180 16 SOLAR (76527)
www.solar-inverter.com
www.deltaenergysystems.com
Monday to Friday from 8 am to 5 pm (except official Bank
Holidays) (3.9 ct/min.)
This cable length
should not exceed
1,000 meters or
3,000 feet.
This cable length
should not exceed
100 meters or
300 feet.
DB25 to RJ45
Adapter (included
with the gateway)
USA & CANADA
EUROPE
Troubleshooting RS485 communication
1. Try a different Ethernet cable if the network or inverter connection is not established. There may be a broken wire in the cable.
2. Verify that the gateway is powered up - Power LED should appear solid green.
3. If the length of the cable is greater than 65 meters or 200 feet, verify that shielded cable is used.
Delta Energy Systems (Australia) Pty. Ltd.
Support Email:
Support Hotline: 61 3 8414 8295