A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should
be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3-
prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before connecting the
machine to the power line, make sure the switch (s) is in the “OFF” position and be sure that the electric current is of
the same characteristics as indicated on the machine. All line connections should make good contact. Running on low
voltage will damage the machine.

DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS.

Fig. A

Fig. B

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE
IS LONGEST OF THE 3 BLADES

GROUNDED OUTLET BOX

GROUNDING

MEANS

ADAPTER

2. Grounded, cord-connected machines intended for
use on a supply circuit having a nominal rating less than
150 volts:

If the machine is intended for use on a circuit that has an
outlet that looks like the one illustrated in Fig. A

,

the machine

will have a grounding plug that looks like the plug illustrated
in Fig. A

A temporary adapter, which looks like the adapter

illustrated in Fig. B, may be used to connect this plug to a
matching 2-conductor receptacle as shown in Fig. B if a
properly grounded outlet is not available. The temporary
adapter should be used only until a properly grounded outlet
can be installed by a qualified electrician. The green-colored
rigid ear, lug, and the like, extending from the adapter must
be connected to a permanent ground such as a properly
grounded outlet box. Whenever the adapter is used, it must
be held in place with a metal screw.

NOTE: In Canada, the use of a temporary adapter is not
permitted by the Canadian Electric Code.

IN ALL CASES, MAKE CERTAIN THE
R E C E P T A C L E I N Q U E S T I O N I S

PROPERLY GROUNDED. IF YOU ARE NOT SURE HAVE A
QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE.

1. All grounded, cord-connected machines: 

In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock. This machine is equipped
with an electric cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into a matching outlet that is properly installed and grounded
in accordance with all local codes and ordinances.

Do not modify the plug provided - if it will not fit the outlet,
have the proper outlet installed by a qualified electrician.

I m p ro p e r c o n n e c t i o n o f t h e e q u i p m e n t - g ro u n d i n g
co n du c t or can result i n ri sk of e le c tric s hoc k . The
conductor with insulation having an outer surface that is
green with or without yellow stripes is the equipment-
grounding conductor. If repair or replacement of the electric
cord or plug is necessary, do not connect the equipment-
grounding conductor to a live terminal.

Check with a qualified electrician or service personnel if the
grounding instructions are not completely understood, or if
in doubt as to whether the machine is properly grounded.

Use only 3-wire extension cords that have 3-prong grounding
type plugs and matching 3-conductor receptacles that
accept the machine’s plug, as shown in Fig. A.

Repair or replace damaged or worn cord immediately.

POWER CONNECTIONS

MOTOR SPECIFICATIONS

Your machine is wired for 120 volts, 60 HZ alternating current. Before connecting the machine to the power source,
make sure the switch is in the “OFF” position. 

GROUNDING INSTRUCTIONS

THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM
ELECTRIC SHOCK.

Содержание ShopMaster MS265

Страница 1: ...ESPA OL P GINA 23 To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 800 223 7278 In Canada call 1 800 463 35...

Страница 2: ...al Mail Technical Service Manager Delta Machinery 4825 Highway 45 North Jackson TN 38305 IN CANADA 125 Mural St Suite 300 Richmond Hill ON L4B 1M4 Information regarding the safe and proper operation o...

Страница 3: ...EMS The symbols below are used to help you recognize this information SAFETY GUIDELINES DEFINITIONS SOME DUST CREATED BY POWER SANDING SAWING GRINDING DRILLING AND OTHER CONSTRUCTION ACTIVITIES contai...

Страница 4: ...the machine and or injury may result 13 USE RECOMMENDED ACCESSORIES The use of accessories and attachments not recommended by Delta may cause damage to the machine or injury to the user 14 USE THE PR...

Страница 5: ...IC SAFETY RULES 20 NEVER RECUT SMALL PIECES 21 NEVER LOCK THE SWITCH in the ON position 22 NEVER APPLY LUBRICANT to a running blade 23 DO NOT PERFORM FREE HAND OPERATIONS Hold the work firmly against...

Страница 6: ...metal screw NOTE In Canada the use of a temporary adapter is not permitted by the Canadian Electric Code IN ALL CASES MAKE CERTAIN THE R E C E P TA C L E I N Q U E S T I O N I S PROPERLY GROUNDED IF Y...

Страница 7: ...number the heavier the cord MINIMUM GAUGE EXTENSION CORD RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES Ampere Total Length Gauge of Rating Volts of Cord in Feet Extension Cord 0 6 120 up...

Страница 8: ...N MANUAL ATTACHING MITER SAW ARM TO BASE Fig 3 B A C ASSEMBLY TOOLS REQUIRED ASSEMBLY TIME ESTIMATE 3mm hex wrench supplied 1 2 Blade Wrench supplied Assembly time for this product will be about 30 mi...

Страница 9: ...he spout see inset B A Fig 5 A Fig 6 Fig 7 A C B FASTENING MACHINE TO SUPPORTING SURFACE Before operating your compound miter saw mount it to a sturdy workbench or other supporting surface Four holes...

Страница 10: ...To stop the miter saw release the switch trigger This saw is equipped with an automatic electric blade brake As soon as the switch trigger A Fig 9 is released the electric brake is activated and stops...

Страница 11: ...itions for cutting crown moulding Refer to the CUTTING CROWN MOULDING section of this manual IMPORTANT Always tighten the lock handle A Fig 13 before cutting POINTER AND SCALE A pointer A Fig 15 is su...

Страница 12: ...RYING HANDLE Fig 18 Fig 19 Fig 20 A A A Fully extend the stabilizer bar before operating the saw The cuttinghead of your compound miter saw can be tilted to cut any bevel angle from a 90 straight cut...

Страница 13: ...and turning the adjusting screw B in or out 2 Lower the blade as far as possible Rotate the blade by hand to ensure that the teeth do not contact any metal surfaces Adjust if necessary 3 After the dow...

Страница 14: ...able Tighten the locknut B ADJUSTING 90 AND 45 BEVEL STOPS 4 Loosen the bevel lock handle and move the cutting arm all the way to the left bevel position Tighten the bevel lock handle 5 Use a combinat...

Страница 15: ...ssibly causing damage or injury TO LIMIT THE POSSIBILITY OF PERSONAL INJURY OR BLADE GUARD DAMAGE MOUNT AN AUXILIARY WOOD FENCE ON YOUR SAW Holes are provided in the fence to attach an auxiliary fence...

Страница 16: ...andard 2 x 6 can be cut in the 90 degree straight cut off position in one pass Fig A3 3 Cutting a standard 4 x 4 can be accomplished with one pass Fig A4 4 This machine has the capacity to accurately...

Страница 17: ...wax is available at most industrial mill supply houses The wax provides proper lubrication and keeps chips from adhering to the blade Never apply lubricant to the blade while the machine is running FE...

Страница 18: ...gle quickly The saw blade is already tilted to the 33 86 left bevel position from the previous cut 5 Place the crown moulding on the table with the WALL EDGE of the crown moulding against the fence an...

Страница 19: ...turning 3 Use a wrench A Fig 44 to loosen the arbor screw C by turning it clockwise 4 Remove the arbor screw C Fig 45 outside blade flange B and saw blade from the saw arbor 5 Attach the new saw blad...

Страница 20: ...CONNECT MACHINE FROM POWER SOURCE 1 Remove three screws A Fig 46 and remove motor cover B 3 Fig 48 illustrates one of the brushes E removed from the holder C When the carbon on either brush E is worn...

Страница 21: ...arest service outlet please call 1 800 223 7278 In Canada call 1 800 463 3582 A complete line of accessories is available from your Delta Supplier Porter Cable Delta Factory Service Centers and Delta...

Страница 22: ...Delta may require that electric motors be returned prepaid to a motor manufacturer s authorized station for inspection and repair or replacement Delta will not be responsible for any asserted defect...

Страница 23: ...7278 y le dirigir n al Centro de Servicio de F brica Porter Cable Delta m s cercano ARIZONA Phoenix 85013 2906 4501 N 7th Ave Phone 602 279 6414 Fax 602 279 5470 CALIFORNIA Ontario 91761 Los Angeles...

Отзывы: