A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should
be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3-
prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before connecting the
machine to the power line, make sure the switch is in the “OFF” position and be sure that the electric current is of the
same characteristics as indicated on the machine. All line connections should make good contact. Running on low
voltage will damage the machine.

DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS.

Fig. A

Fig. B

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE
IS LONGEST OF THE 3 BLADES

GROUNDED OUTLET BOX

GROUNDING

MEANS

ADAPTER

2. Grounded, cord-connected machines intended for use
on a supply circuit having a nominal rating less than 150
volts:

If the machine is intended for use on a circuit that has an
outlet that looks like the one illustrated in Fig. A

,

the

machine will have a grounding plug that looks like the plug
illustrated in Fig. A

A temporary adapter, which looks like

the adapter illustrated in Fig. B, may be used to connect
this plug to a matching 2-conductor receptacle as shown
in Fig. B if a properly grounded outlet is not available. The
temporary adapter should be used only until a properly
grounded outlet can be installed by a qualified electrician.
The green-colored rigid ear, lug, and the like, extending
from the adapter must be connected to a permanent
ground such as a properly grounded outlet box. Whenever
the adapter is used, it must be held in place with a metal
screw.

NOTE: In Canada, the use of a temporary adapter is not
permitted by the Canadian Electric Code.

1. All grounded, cord-connected machines: 

In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock. This machine is
equipped with an electric cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into a matching outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.

Do not modify the plug provided - if it will not fit the outlet,
have the proper outlet installed by a qualified electrician.

Improper connection of the equipment-grounding
conductor can result in risk of electric shock. The
conductor with insulation having an outer surface that is
green with or without yellow stripes is the equipment-
grounding conductor. If repair or replacement of the
electric cord or plug is necessary, do not connect the
equipment-grounding conductor to a live terminal.

Check with a qualified electrician or service personnel if
t h e g r o u n d i n g i n s t r u c t i o n s a r e n o t c o m p l e t e l y
understood, or if in doubt as to whether the machine is
properly grounded.

Use only 3-wire extension cords that have 3-prong
grounding type plugs and matching 3-conductor
receptacles that accept the machine’s plug, as shown in
Fig. A.

Repair or replace damaged or worn cord immediately.

POWER CONNECTIONS

MOTOR SPECIFICATIONS

Your machine is wired for 120 volt, 60 HZ alternating current. Before connecting the machine to the power source,
make sure the switch is in the “OFF” position. 

GROUNDING INSTRUCTIONS

THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM
ELECTRIC SHOCK.

Содержание ShopMaster DP400

Страница 1: ...PART NO 907453 04 13 04 Copyright 2004 Delta Machinery ESPA OL P GINA 21 To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance...

Страница 2: ...UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT Failure to follow all instructions listed below may result in electric shock fire and or serious personal injury or prop...

Страница 3: ...Tools scrap pieces and other debris can be thrown at high speed causing injury 12 USE THE RIGHT MACHINE Don t force a machine or an attachment to do a job for which it was not designed Damage to the...

Страница 4: ...ITIONS A sudden slip could cause a hand to move into the bit 14 KEEP ARMS HANDS AND FINGERS away from the bit Serious injury to the hand can occur 15 HOLD THE WORKPIECE FIRMLY AGAINST THE TABLE Do not...

Страница 5: ...rounded outlet box Whenever the adapter is used it must be held in place with a metal screw NOTE In Canada the use of a temporary adapter is not permitted by the Canadian Electric Code 1 All grounded...

Страница 6: ...2 AWG 10 12 120 up to 25 16 AWG 10 12 120 25 50 16 AWG 10 12 120 50 100 14 AWG 10 12 120 100 150 12 AWG 12 16 120 up to 25 14 AWG 12 16 120 25 50 12 AWG 12 16 120 GREATER THAN 50 FEET NOT RECOMMENDED...

Страница 7: ...EPICT THE ACTUAL COLOR LABELING OR ACCESSORIES AND MAY BE INTENDED TO ILLUSTRATE TECHNIQUE ONLY DRILL PRESS PARTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 21 22 19 Fig 2 1 Drill Press Head 2 Ta...

Страница 8: ...base with the minimum dimensions as shown in Fig 4 for mounting the drill press base to a supporting surface 3 Place the drill press base D Fig 5 centered on the supporting surface E MAKE SURE THERE...

Страница 9: ...s C three of which are shown Fig 6 7 Assemble table raising and lowering handle D Fig 7 to worm gear shaft E and tighten screw F against flat on shaft with 3mm wrench supplied Fig 7 Fig 8 8 Thread tab...

Страница 10: ...g 11 with the 5mm wrench supplied 12 IMPORTANT Make certain the tapered hole in the bottom of spindle T Fig 13 and the taper on spindle adapter U are clean and free of any grease lacquer or rust preve...

Страница 11: ...ety rules concerning its use 15 IMPORTANT OPEN THE CHUCK JAWS AS WIDE AS POSSIBLE MAKING SURE THE CHUCK JAWS ARE INSIDE THE CHUCK 16 Holding chuck on taper of spindle tap with a soft tip hammer Q or a...

Страница 12: ...8 through the hole in the cord strain relief bracket and the lamp bracket and thread the screw into the drill press head Repeat this process for the remaining hole in the cord strain relief bracket an...

Страница 13: ...nce but cannot be restarted without inserting the switch toggle B Fig 21 B FLEXIBLE LAMP The flexible lamp operates independently of the drill press To turn the lamp ON and OFF rotate switch A Fig 22...

Страница 14: ...in C removed Loosen table locking bolt D tilt table to the desired angle and tighten bolt D When returning table to the level position replace table alignment pin C This will position the table surfac...

Страница 15: ...he tension knob located on the other side of the head casting and moving tension lever C forward pivoting the motor D toward the front of the drill press 3 While holding the motor toward the front of...

Страница 16: ...N SPRING The spindle is automatically returned to its upper most position when the handle is released It is recommended that the handle be allowed to slowly return to the top position after each hole...

Страница 17: ...or a vise Fig 33 D C A B INSTALLING AND REMOVING DRILL BITS DISCONNECT MACHINE FROM POWER SOURCE 1 Insert smooth end of drill bit A Fig 33 into chuck B as far as it will go and then back the bit out 1...

Страница 18: ...the work when drilling metal The work should never be held in the bare hand the drill bit may seize the work at any time especially when breaking through the stock If the piece is whirled out of the o...

Страница 19: ...19 NOTES...

Страница 20: ...at its option any new Delta machine machine part or machine accessory which in normal use has proven to be defective in workmanship or material provided that the customer returns the product prepaid t...

Страница 21: ...elta m s cercano ARIZONA Tempe 85282 Phoenix 2400 West Southern Avenue Suite 105 Phone 602 437 1200 Fax 602 437 2200 CALIFORNIA Ontario 91761 Los Angeles 3949A East Guasti Road Phone 909 390 5555 Fax...