GLOSSARY

Become familiar with these terms before operating the unit.
CFM:  Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
PSIG: Pounds per square inch gauge; a unit of measure of pressure.
Code Certification: Products that bear one or more of the following marks:
UL, CUL, ETL, CETL, 

CSA/US

have been evaluated by OSHA certified

independent safety laboratories and meet the applicable Underwriters
Laboratories Standards for Safety.
CSA:  Electrical products sold in Canada are required to be certified to the
applicable CSA standard (s). Canadian Standards Association (CSA) is a
standards writing and safety testing organization. Products that are CSA
certified have been evaluated and tested and found to meet or exceed the
applicable CSA standard (s) for safety and electrical performance.
Cut-In Pressure: While the motor is off, air tank pressure drops as you
continue to use your accessory. When the tank pressure drops to a certain low
level the motor will restart automatically.  The low pressure at which the motor
automatically restarts is called “cut-in” pressure.
Cut-Out Pressure: When an air compressor is turned on and begins to run,
air pressure in the air tank begins to build.  It builds to a certain high pressure
before the motor automatically shuts off - protecting your air tank from
pressure higher than its capacity.  The high pressure at which the motor shuts
off is called “cut-out” pressure.
Branch Circuit: Circuit carrying electricity from electrical panel to outlet.

Model No.

CP200

Voltage/Hertz/ Phase

120V/60/1

Minimum Branch Circuit Requirement

15 amps

*Fuse Type

Time Delay

Air Tank Capacity

2 gallons

Approximate Cut-in Pressure

75 PSI

Approximate Cut-out Pressure

100 PSI

SPECIFICATIONS

* A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same
rating as the branch circuit on which the air compressor is operated. If
compressor is connected to a circuit protected by fuses, use only time delay
fuses. Time delay fuses should be marked “D” in Canada and “T” in the US.

Содержание ShopMaster CP200

Страница 1: ...ight 2002 Delta Machinery To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 866 422 4286 Oil Free Air Compres...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...ediately with a new tank or replace the entire compressor 1 Failure to properly drain condensed water from tank causing rust and thinning of the steel tank 2 Modifications or attempted repairs to the...

Страница 5: ...the compressor is connected provides proper electrical grounding correct voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream...

Страница 6: ...can cause serious injury if they com into contact with you or your clothing HOW TO PREVENT IT WHAT CAN HAPPEN WARNING RISK OF FALLING A portable compressor can fall from a table workbench or roof cau...

Страница 7: ...at all times Do not operate the product when fatigued or under the influence of alcohol or drugs Stay alert at all times Never defeat the safety features of this product Equip area of operation with a...

Страница 8: ...r accessory When the tank pressure drops to a certain low level the motor will restart automatically The low pressure at which the motor automatically restarts is called cut in pressure Cut Out Pressu...

Страница 9: ...has been installed and grounded in accordance with all local codes and ordinances 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPORTAN...

Страница 10: ...if operation of the compressor repeatedly causes interruption of the power it may be necessary to operate it from a 20 amp circuit It is not necessary to change the cord set Extension Cords Using exte...

Страница 11: ...k Pressure Gauge The tank pressure gauge indicates the reserve air pressure in the tank Regulator Controls the air pressure shown on the outlet pressure gauge Pull the knob out and turn clockwise to i...

Страница 12: ...ir receiver will fill to cut out pressure and the motor will stop The compressor is now ready for use How to Use Your Unit How to Stop 1 Set the Auto On Off switch to OFF NOTE It is normal for the fan...

Страница 13: ...k by opening drain valve counter clockwise on bottom of tank NOTE Tilt tank forward to drain tank completely Water will condense in the air tank If not drained water will corrode and weaken the air ta...

Страница 14: ...mately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will condense in the air tank If not drained water will corrode and weaken the air ta...

Страница 15: ...tings with pipe sealant tape and retighten securely Do Not Overtighten If leaks continue contact a Trained Service Technician Air leaks at fittings Air leaks in air tank or at air tank welds Defective...

Страница 16: ...s Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Air leaks Decrease amount of air usage Check the accessory air requirement If it is higher than the SCF...

Страница 17: ...electrical appliances from circuit or operate the compressor on its own branch circuit Have checked by a Trained Service Technician Fuse blown circuit breaker tripped Extension cord is wrong length or...

Страница 18: ...rs with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Authorized Warranty Service Center that provides on site service calls for service call arrangements If...

Отзывы: