Delta OIL-FREE AIR COMPRESSOR CP503 Скачать руководство пользователя страница 3

3- ENG

A08200

IMPORTANT SAFETY INSTRUCTIONS

Save these instructions

Improper operation or maintenance of this product could result in serious injury and 
property damage. Read and understand all warnings and operation instructions before 
using this equipment.

HAZARD

WARNING: Risk of explosion or fire

How To Prevent It

What Could Happen

It is normal for electrical contacts 

within the motor and pressure switch

 to 

spark.

If 

electrical 

sparks

 from compressor 

come into contact with flammable 

vapors, they may ignite, causing fire or 

explosion.

Restricting

 any of the 

compressor 

ventilation openings

 will cause serious 

overheating and 

could cause fire.

Unattended operation

 of this product 

could result in personal injury or 

property damage. To reduce the risk 

of fire, do not allow the compressor to 

operate unattended.

Always 

operate the compressor in a

 

well ventilated 

area free of combustible 

materials, gasoline, or solvent vapors.

If spraying flammable materials, 

locate 

compressor at least 20 feet away from 

spray area.

 An additional length of hose 

may be required.

Store flammable materials in a secure 

location away from compressor.

Never place objects against or on top 

of compressor. Operate compressor

 

in an open area 

at least 12 inches 

away from

 any

 wall or obstruction

 that 

would restrict the flow of fresh air to  the 

ventilation openings.
Operate compressor in a clean, dry well 

ventilated area.

 Do not operate unit 

indoors or in any confined area.
Always remain in attendance

 with the 

product when it is operating.

Always disconnect electrical power by 

moving pressure switch lever to the off 

position and drain tank daily or after 

each use.

Содержание OIL-FREE AIR COMPRESSOR CP503

Страница 1: ...t 2004 Delta Machinery To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 866 422 4286 Oil Free Air Compressor...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Страница 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Страница 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Страница 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Страница 8: ...nderwriters Laboratories Standards for Safety Cut In Pressure While the motor is off air tank pressure drops as you continue to use your accessory When the tank pressure drops to a certain low level t...

Страница 9: ...t up and down stairs or steps The unit must be lifted or pushed up a ramp 1 Submerge handle grip into warm soapy water to make installation easier Remove handle grip from soapy water and slide onto ha...

Страница 10: ...4 If these grounding instructions are not completely understood or if in doubt as to whether the compressor is properly grounded have the installation checked by a qualified electrician IMPROPER GROUN...

Страница 11: ...ther electrical needs lights appliances etc 3 Extension cords comply with specifications 4 Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse NOTE If compressor is connected t...

Страница 12: ...is always less than or equal to the tank pressure Tank Pressure Gauge The tank pressure gauge indicates the reserve air pressure in the tank Regulator Controls the air pressure shown on the outlet pr...

Страница 13: ...ON AUTO position The compressor will start 5 Run the compressor for 15 minutes Make sure the drain valve is open and there is minimal air pressure build up in tank 6 After 15 minutes close the drain...

Страница 14: ...ety valve ring 5 Drain water from air tank by opening drain valve counter clockwise on bottom of tank Water will condense in the air tank If not drained water will corrode and weaken the air tank caus...

Страница 15: ...rn clockwise 7 Replace the outlet tube and tighten the nut 8 Perform the Break in Procedure See Break in Procedure in the Operation section SERVICE AND ADJUSTMENTS Unit cycles automatically when power...

Страница 16: ...cheduled maintenance as necessary 2 Set the On Auto Off lever to OFF 3 Turn the regulator counterclockwise and set the outlet pressure to zero 4 Remove the air tool or accessory 5 Pull ring on safety...

Страница 17: ...re air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve if equipped Defective pressure switch release...

Страница 18: ...accessory is being used Compressor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restric...

Страница 19: ...heck for proper fuse You should use a time delay fuse Check for low voltage problem Check the extension cord Disconnect the other electrical appliances from circuit or operate the compressor on its ow...

Страница 20: ...ser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Authorized Warranty Service Center that provides on site service calls for service cal...