12- ENG

D26195

Description of Operation

Become familiar with these controls before operating the unit.

On/Auto/Off Switch

: Turn this

switch ON to provide automatic
power to the pressure switch and
OFF to remove power at the end
of each use.

Pressure Switch:

The pressure

switch automatically starts the
motor when the air tank pressure
drops below the factory set "cut-
in" pressure. It stops the motor
when the air tank pressure
reaches the factory set "cut-out"
pressure.

Safety Valve:

If the pressure

switch does not shut off the air compressor at its "cut-out" pressure setting,
the safety valve will protect against high pressure by "popping out" at its
factory set pressure (slightly higher than the pressure switch "cut-out" setting).

Outlet Pressure Gauge:

The outlet pressure gauge indicates the air pressure

available at the outlet side of the regulator. This pressure is controlled by the
regulator and is always less than or equal to the tank pressure. 

Tank Pressure Gauge:

The tank pressure gauge indicates the reserve air

pressure in the tank. 

Regulator:

Controls the air pressure shown on the outlet pressure gauge. Pull

the knob out and turn clockwise to increase pressure and counterclockwise to
decrease pressure. When the desired pressure is reached push knob in to lock
in place.

Drain Valve:

The drain valve is located at the base of the air tank and is used

to drain condensation at the end of each use.

Cooling System (not shown)

:  This compressor

contains an advanced design cooling system. At
the heart of this cooling system is an engineered
fan. It is perfectly normal for this fan to blow air
through the vent holes in large amounts. You
know that the cooling system is working when air
is being expelled.

Air Compressor Pump (not shown):

Compresses air into the air tank.

Working air is not available until the compressor has raised the air tank
pressure above that required at the air outlet.

Safety Valve

OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with
the location of various controls and adjustments. Save this manual for future
reference.

On/Auto/Off

Switch

Regulator

Outlet 

Pressure

Gauge

Tank Pressure Gauge

Pressure 

Switch

Drain 

Valve

Содержание Oil-Free 66-651

Страница 1: ...ight 2002 Delta Machinery To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 866 422 4286 Oil Free Air Compres...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...or 1 Failure to properly drain condensed water from tank causing rust and thinning of the steel tank 2 Modifications or attempted repairs to the tank 3 Unauthorized modifications to the unloader valve...

Страница 5: ...the compressor is connected provides proper electrical grounding correct voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream...

Страница 6: ...can cause serious injury if they com into contact with you or your clothing HOW TO PREVENT IT WHAT CAN HAPPEN WARNING RISK OF FALLING A portable compressor can fall from a table workbench or roof cau...

Страница 7: ...unauthorized parts HOW TO PREVENT IT WHAT CAN HAPPEN WARNING RISK OF UNSAFE OPERATION Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD HOW TO PREV...

Страница 8: ...essure drops to a certain low level the motor will restart automatically The low pressure at which the motor automatically restarts is called cut in pressure Cut Out Pressure When an air compressor is...

Страница 9: ...t be lifted or pushed up a ramp Assemble Rubber Feet 1 Attach rubber feet with the screws provided as shown in previous figure 2 Tighten securely Rubber Feet Screw Nut Wheel Shoulder Bolt ASSEMBLY Too...

Страница 10: ...se if there are signs of damage 4 If these grounding instructions are not completely understood or if in doubt as to whether the compressor is properly grounded have the installation checked by a qual...

Страница 11: ...and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is...

Страница 12: ...tank Regulator Controls the air pressure shown on the outlet pressure gauge Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure When the desired pressu...

Страница 13: ...arting Break in instructions Serious damage may result if the following break in instructions are not closely followed This procedure is required before the air compressor is put into service and when...

Страница 14: ...nnect plug if the air outlet is equipped with a quick connect Too much air pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and accessories T...

Страница 15: ...ype of valve To Drain Tank 1 Set the On Auto Off lever to OFF 2 Pull the regulator knob out and turn clockwise to set the outlet pressure to zero 3 Remove the air tool or accessory 4 Pull ring on safe...

Страница 16: ...o Drain Tank in the Maintenance section 2 Unplug outfit 3 Using an adjustable wrench loosen outlet tube nut at air tank and pump Carefully move outlet tube away from check valve 4 Using an adjustable...

Страница 17: ...2 Unplug compressor 3 Remove the outlet pressure gauge and quick connect if equipped from the regulator 4 Remove the regulator 5 Apply pipe sealant tape to the nipple 6 Assemble the regulator and ori...

Страница 18: ...roximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will condense in the air tank If not drained water will corrode and weaken the ai...

Страница 19: ...ttings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve Defective pressure switch release va...

Страница 20: ...essor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air...

Страница 21: ...ch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Extension cord is wro...

Страница 22: ...2 ENG D26195 AIR COMPRESSOR DIAGRAM Torque 5 7 ft lbs 5 24 26 27 28 25 9 10 21 15 16 17 6 7 10 11 14 18 4 3 Torque 9 12 ft lbs 2 1 Torque 15 25 ft lbs 32 31 Torque 100 120 in lbs 8 29 30 19 23 22 5 20...

Страница 23: ...NPT 14 Z AC 0746 Pressure Switch 15 SSP 480 Nipple 1 4 x 2 5 16 SSW 7482 Connector Conduit 3 8 17 TIA 4150 Safety Valve 18 SUDL 413 2 Cord Assembly 19 D23138 Wheel 9 2 used 20 AC 0609 Handle 21 SS 128...

Страница 24: ...4 ENG D26195 AIR COMPRESSOR PUMP DIAGRAM Torque 51 63 in lbs Torque 100 120 in lbs Torque 100 120 in lbs Torque 7 10 ft lbs Torque 42 48 in lbs 83 84 85 90 89 87 81 80 91 78 72 70 74 73 76 79 92 93 88...

Страница 25: ...e 79 Connecting Rod Assembly 80 SSG 8156 O Ring 81 Z AC 0032 Valve Plate Assembly 83 ACG 45 O Ring 84 AC 0037 Head 85 SSF 927 Screw 1 4 20 x 1 125 4 used 87 Muffler Intake 88 Screen Filter 89 DAC 143...

Страница 26: ...Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Authorized Warranty Service Center that provides on site service calls for service call a...

Отзывы: