>50 cm
>80 cm
>40 cm
>60 cm
>60 cm
>60 cm
► Ensure sufficient air circulation. Hot air
must be able to dissipate upwards. Lea-
ve enough space around each inverter.
► Do not install inverters above one ano-
ther so that they do not heat each other.
► Note the
Operating temperature ran-
ge without derating
and the
Operating
temperature range
. When the
Operating
temperature range without derating
is
exceeded, the inverter reduces the AC
power fed into the mains grid. When the
Operating temperature range
is excee-
ded, the inverter stops feeding AC power
into the mains. This is normal operating
behavior for the inverter and is necessary
to protect the internal electronics.
► In areas with many trees or fields, pollen
can clog the air inlets and outlets, hinde-
ring the air flow.
Installation clearances and air circulation
Lifting and transporting the inverter
► Screw the eyebolts onto the top side of the inverter. The
screw eyebolts are not included in the scope of delivery.
► Lift the inverter using a block and tackle or crane.