![Delta HPP-1K5A01KAT Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/delta/hpp-1k5a01kat/hpp-1k5a01kat_user-manual_2474087007.webp)
4.
2.2.
Key Feature
Advanced SiC mosfets module implement:
The highest power level of pulse DC generator.
The widest frequency adjustment.
Lossless Snubber circuit.
Clamp voltage stress of pulse switch.
Less oscillation.
Ultra low arc energy (< 200uJ/KW)
Configurable reverse voltage (50V~100V)
Chapter 3: Specification
3.1.
System Block Diagram
Taipei rectifier PFC Module
Breaker
Three phase
AC Input
Full Bridge
module
Output
Measurement
Pulsed DC
module
Pulsed DC
Output
Housekeeping
Supplies
Control Circuit
Front Panel Display
Isolated Remote Interfaces
Adaptable Fan
Configurable
power supply
Figure 3.1 System Block Diagram of Delta “HPP-1K5A01KAT”
Table 3.1 Detail Description for Block Diagram
Taipei rectifier PFC Module
Three phase main voltage is applied while breaker is closed. After
Taipei rectifier PFC, soft start mechanism suppresses inrush current
to prevent any damage. A good power factor condition back to the
mains then is modified through Taipei rectifier PFC and AC voltage
is rectified to DC bus for DC-DC Section.
Full Bridge Module
The converter section converts DC voltage stored in the bulk
capacitors to high-frequency voltage by alternating the current
through switching power components. In the output side, an isolation
transformer steps up the high-frequency voltage from the converter
section and delivers it to a full-wave rectifier bridge. The rectified DC
power is then passed through a measurement section to the output
connector.
Pulse DC Module
In the pulse section, an inductor and a controlled switch are
responsible for generating pulse output from straight DC.
Output Measurement and
Feedback
The output measurement section measures current and voltage, and
feedback the voltage and current information to MCU for voltage,
current and power control and related protection.