1-5. Configuration & Maintenance 

Make  sure  the  heat  exchanger  surface  sealed  with  mounting  flange  to  avoid  water 
penetrates into shelter through mounting interface. It is suggested to use gaskets sticking 
on the mounting flange and seal the gap between flange and cabinet with silicone gel 
during  installation.  There  should  be 

NO

  any  gap  surround  gaskets  to  avoid  water 

penetrates into enclosure. 
The HEX is composed of the key components as the following: Chassis, Heat Exchange 
Core, Controller and Fan tray, user can slide out the fan tray easily for replacement of 
the controller and fans. 

1

3

2

4

7

8

5

6

 

 

In order to assure the heat exchanger running at optimal condition, the core should be 
cleaned once annually at least; user can clean the core with water directly. The external 
side  fan  blade  can  also  be  cleaned  with  normal  pressure  water  if  there  is  dust 
accumulation.  Please  do  not  use  strong  water  jet  to  impact  the  center  of  fan  and  the 
surface  of  core.  The  bottom  hole  of  the  heat  exchanger  should  be  clear  when  the 
maintenance. Please also notice that: 

 

1.  Check wires are connected correctly, and the insulation is not cracking or broken. 

2.  Use Self-test to check the unit running correctly or not. And the supplied air of internal 

side should be as cooled air. 

3.  Do not wipe the product with organic solvent, volatile substances like toluene or gasoline, 

it will destroy the powder-coated surface. 

4.  Turn off the power before maintaining. 

5.  Please turn off power and remove dry contact connector while non-operating for a long 

time. 

NO. Q'TY

DESCRIPTION 

Case Cover 

Heat exchange (Core) 

Case Body 

External Fans 

External Case Cover 

Internal Case Cover 

Internal Fans 

Controller 

Содержание HEX110QA

Страница 1: ...EX110QA Rev 00 Sample Date Code Sample Issue Date June 2 2020 DELTA ELECTRONICS INC 252 SHANG YING ROAD KUEI SAN TEL 886 0 3 3591968 TAOYUAN CITY 333 TAIWAN FAX 886 0 3 3591991 Please send one copy of...

Страница 2: ...mber 7 1 3 Dimension 9 1 4 Mounting Panel Cutout 10 1 5 Configuration Maintenance 11 1 6 Thermal and Airflow 12 2 Electrical Specification 13 2 1 Indicator Connector 13 2 2 Cooling capacity temperatur...

Страница 3: ...with care Do not place heavy objects on top of the box Pay attention to the below icons on the package Please check product function by self test process and make sure no alarm signal and abnormal aco...

Страница 4: ...at has leaked from refrigerant pipes or other areas as there is a danger of frostbite 6 Before serving or cleaning unit switch power off and disconnect power supply 7 When cutting or drilling into wal...

Страница 5: ...ace where there is a danger or flammable gas leakage 5 Arrange the drain to ensure complete drainage 6 To avoid injury do not touch the air inlet or aluminum fins of the unit 7 Watch your step at the...

Страница 6: ...el no HEX110QA Page 6 Specification for Approval Customer Description Heat Exchanger 110W K Customer P N Rev Delta model no HEX110QA Rev 00A Sample revision Date Code Sample issue date Quantity 1 pcs...

Страница 7: ...del Number Dimensions Weight Mounting method Dimension H x W x D without flange mm inch 536 x 447 x 220 21 1 x 17 6 x 8 7 Application Outdoor Weight Kg lbs 15 0 33 1 Mounting Method Roof Color optiona...

Страница 8: ...nal Airflow m3 h CMH 400 Power Range Input Voltage VDC 48 Input Voltage Range VDC 40 60 Rated DC Current A 5 0 Alarm N A Dry Contact Output Key Components Controller Built in Smart Controller Communic...

Страница 9: ...Part no Delta model no HEX110QA Page 9 1 3 Dimension 1 Material Aluminum sheet t 1 5mm 2 Finish Powder painting 75um MIN 3 Color RAL 7035 3 Dimension tolerance X X 1 0 mm mm...

Страница 10: ...Part no Delta model no HEX110QA Page 10 1 4 Mounting Panel Cutout M5 SCREW WITH SKIDPROOF WASHER OR NYLOK 20X SYSTEM PANEL EXTERNAL SIDE INTERNAL SIDE AND SYSTEM PANEL...

Страница 11: ...lean the core with water directly The external side fan blade can also be cleaned with normal pressure water if there is dust accumulation Please do not use strong water jet to impact the center of fa...

Страница 12: ...arm air generated by the equipment will be blowing into the internal return opening and pass though the HEX then flow out from internal supply opening the cold supply air will be used to cool down the...

Страница 13: ...m N C dry contact 6 RS485 A Reserved 7 RS485 B Reserved Alarm contact rating max 60VDC 100mA 2 LED Indicator Mate with DINKLE 2ESDVM 07P HEX status FAN SENSOR Power off Dark Dark HEX normal power on G...

Страница 14: ...ting Temperature 10 C 55 C 14 F 131 F Storage Temperature 40 C 70 C 40 F 158 F Operation Humidity External air loop 0 100 RH Internal air loop 0 90 RH non condensing Ingress Protection Rating IP55 IEC...

Страница 15: ...gh temp High humidity IEC 60068 2 3 Temperature cycle IEC 60068 2 14 test Nb Vibration ETSI 300 019 1 4 CLASS 4 1 Ingress protection external side IEC 60529 IP55 NEMA TYPE 4 Salt fog test external sid...

Страница 16: ...X capacity is not match the load of the system The ambient temperature is too high Low efficiency of the outside Other system failure Check the heating load of the system Ensure the TEC is operating i...

Страница 17: ...A Page 17 9 Reclaim At the end of the unit working life the produce must not be disposed of as urban waste It must be taken to a special local authority differentiated waste collection center or to a...

Страница 18: ...Part no Delta model no HEX110QA Page 18 10 Versions REV DESCRIPTION DRAWN CHECKED APPROVED ISSUE DATE ME EE CE 00 ISSUE SPEC KC Liao KC Liao Ted Tu Mars Wu 2020 6 02...

Отзывы: