Delta HEC2010FFA Скачать руководство пользователя страница 3

Part no. :   
Delta model no. : HEC2010FFA 

 

 

 

Page 3   

Description 

This document is an installation and the characteristics of Delta HEC series. Before installing the unit, 

please  read  this  manual  thoroughly,  and  following  the  instructions  contained  in  it. The  document  is  the 

exclusive property of Delta Electronics, Inc. it should not be distributed, reproduced, or any other format 

without prior permission of Delta. Specifications are subject to change without notice. 

 

Packing & Shipping 

During handling or transport, air conditioner must be upward placed, 

NO

 inverted, flat, excessive 

tilt and collision. Air conditioner is a precision instrument, it should be handled or transported with care, do 

not stand on the box, or place heavy objects on it. Please pay attention to the following icons on the package.

 

 

If air conditioner is toppled, over slanted or dropped unfortunately, please follow below steps: a. stand 

for 12 hours to ensure refrigerant pressure stability, b. power on and execute self-test to make sure no alarm 

happened, c. air conditioner keeps 1 hour operating and make sure there is no abnormal acoustic noise. 

 

 

Safety Notes 

Please read the safety notes carefully before installing air conditioning unit and be sure to install it 

correctly. After completing the installation, make sure that the unit operates properly during the start-up 

operation. 

 

Meaning of WARNING and CAUTION notices: 

 

Warning: 

Failure to follow these instructions properly may result in personal injure or loss life. 

 

 

Caution: 

Failure to observe these instructions properly may result in property damage or personal injury, which 

may be serious depending on the circumstance. 

 

 

 

 

Содержание HEC2010FFA

Страница 1: ...l No HEC2010FFA Rev 07 Sample Date Code Sample Issue Date JUNE 17 2020 DELTA ELECTRONICS INC 252 SHANG YING ROAD KUEI SAN TEL 886 0 3 3591968 TAOYUAN CITY 333 TAIWAN FAX 886 0 3 3591991 Please send on...

Страница 2: ...Configuration Maintenance 11 1 6 Thermal and Airflow 12 2 Electrical Specification 13 2 1 Indicator Connector 13 2 1 1 Power Supply Alarm Connector 13 2 2 Parametric Setup 14 2 3 Self Test 15 3 Enviro...

Страница 3: ...bjects on it Please pay attention to the following icons on the package If air conditioner is toppled over slanted or dropped unfortunately please follow below steps a stand for 12 hours to ensure ref...

Страница 4: ...ling into wall or ceiling do not damage electrical wiring or hidden utilities 8 Be sure to use only the specified accessories and parts for installation work 9 Protective earth connection The enclosur...

Страница 5: ...onditioner while moving or storage 8 The hole in the bottom of the air conditioner should be connected to a sealed container through a drainpipe 9 The appliance is not to be used by persons including...

Страница 6: ...pecification for Approval Customer Description Air conditioner for Equipment with 2000 W or 100W K Rated Cooling Capacity Customer P N Rev Delta model no HEC2010FFA Rev 07 Sample revision Date Code Sa...

Страница 7: ...N A 1 2 Main Feature Model Number Dimensions Weight Mounting method Dimension H x W x D without flange Mm inch 945 x 505 x 250 37 2 x 19 9 x 9 8 Application Outdoor Weight Kg lbs 40 88 Mounting Method...

Страница 8: ...m3 h CFM 600 354 Heating Capacity W 1000 Power Range Input Voltage Control and Fan VDC 48 Input Voltage Compressor VAC Phase frequency 230 1 50 60 Locked Rotor Current Compressor A 20 2 50Hz 18 9 60H...

Страница 9: ...Part no Delta model no HEC2010FFA Page 9 1 3 Dimension mm inch 1 Material Case SGCC Sheet 2 Finish Powder coating 75 120 uM Color RAL 7035 3 Dimensional Tolerance 1 mm Drain pipe...

Страница 10: ...Part no Delta model no HEC2010FFA Page 10 1 4 Mounting Panel Cutout mm inch GASKET INSIDE OUTSIDE DOOR...

Страница 11: ...denser with water directly The external side fan blade can also be cleaned with normal pressure water if there is dust accumulation Please do not use strong water jet to impact the center of fan and t...

Страница 12: ...l protecting cover is sealed with silicon for IP55 requirement Please do not dismantle the sealed cover or will lose the quality assurance of the compressor 1 6 Thermal and Airflow The internal and ex...

Страница 13: ...Alarm Default Setup Specification Contact rating 30 VDC 1A Normal NC and COM dry contact output close Any alarms happening NC and COM dry contact output open Dry Contact will trigger when alarm happen...

Страница 14: ...ts into self test mode and the LED will flash in green C Press Buttons UP or increase DOWN or decrease SET Parametric setup or into self test function 2 2 Parametric Setup Panel menu Content Range d1...

Страница 15: ...rnal fan speed Display d2 06 DC input voltage Display d2 07 AC input voltage Display d2 08 Firmware version Display 2 3 Self Test 1 Press the SET button into parametric setup mode 2 Press UP button to...

Страница 16: ...ure sensor abnormality Cabinet temperature sensor fault alarm E 3 1 Evaporator temperature sensor fault alarm E 3 2 Condenser temperature sensor fault alarm E 3 3 Ambient temperature sensor fault alar...

Страница 17: ...se contact Delta or authorized Delta service agent The air conditioner is running but the cabinet temperature is still high no obvious cooling effect The air conditioner capacity is not match the load...

Страница 18: ...F 131 F 3 2 Storage Temperature 40 C 70 C 40 F 158 F 3 3 Operation Humidity External air loop 0 100 RH Internal air loop 0 80 RH 3 4 Ingress Protection Rating IP55 IEC60529 on external side GR487 on e...

Страница 19: ...ty Certification TBD 6 Accessory Power Cable Pin Description Cable wire size 1 PE 16AWG 2 N 18AWG 3 L 18AWG 4 N A N A 5 48VDC 18AWG 6 RTN 18AWG 7 Installation Notice Check the surrounding obstacles to...

Страница 20: ...FA Page 20 8 Reclaim At the end of the unit working life the produce must not be disposed of as urban waste It must be taken to a special local authority differentiated waste collection center or to a...

Страница 21: ...ue SPEC VIC 2018 10 23 01 Modify air flow VIC 2018 11 22 02 Modify SPEC table VIC 2018 11 29 03 Modify cable dimension VIC 2018 11 29 04 Issue SPEC VIC 2018 12 07 05 Issue SPEC VIC 2018 12 10 06 Modif...

Отзывы: